background image

P/N 466-

5418 • REV A • 7MAR18 

 

 © 

2018 United Technologies Corporation. All rights reserved

 

 

  TX-E121 Command Button 

– Installation Instructions

PLEASE SEE REVERSE SIDE FOR IMPORTANT  PRODUCT  WARNINGS 
AND DISCLAIMER INFORMATION. 
 
Description (See rev erse side for product w arnings and disclaimers) 

The TX-E121 Command Button  allows for up to  3 different commands,  scenes, and/or automations  to  be 
triggered through three different button pressing sequences. To the security panel, the button appears as 
3 door/window  sensor zones, each  with their own  unique TX-ID (located on the printed card included in 
the  box). Depending on the  security 

panel’s capability and/or the capability of the interactive services 

utilized with the panel

, triggering any of the Command Button’s 3 zones can be set up as the initiating 

action to then  trigger a pre-configured automation or rule.  

Figure 1: TX-E121 Command Button 

 

Enrolling 

 

Keep  in mind that to  the panel,  each command  appears as a  door/window  sensor open, followed  by  an 
automatic  restoral. When enrolling the device, it is recommended to name  each zone accordingly so they 
can easily be assigned to the scene of your choice. For instance, zone #1 = “CB1 ST” (command button 

single tap), zone #2 = “CB1 DT” (for double tap), and zone #3 = “CB1 PH” (for press and hold). 

 

To enroll the command-

button into the panel utilizing the panel’s “Learn Mode” procedure, the sensor 

needs  to be placed into  enrollment mode.  To enter enrollment mode  on the  button,  follow these steps: 

1) 

Press and hold the  button  for approximately  10  seconds. During this 10 second time frame, the 

LED will blink three times, then  remain on for 3 more seconds. Continue  holding down the button  and  after 

a total  of approximately  10 seconds, the  LED will quickly flash 5 times indicating that enrollment mode has 

been  enabled. 

2) 

With the  panel in learn mode,  briefly tap the  button  once to trigger a tamper transmission for zone 

#1.  This should successfully learn it into the panel. If the panel does  not respond,  wait for the LED to shut 

off and  try pressing the button again, until successful enrollment occurs.  

3) 

After the panel  has recognized the first zone, 

be 

sure to assign it to a zone type that is “chime 

only”.

 Because  each zone transmits as a door/window  sensor, a chime-only  zone type  is necessary to 

ensure that  the panel  does not go into alarm if the system  is armed and the  end  user wishes to activate  a 

particular scene or automation.  

 

For Simon, Concord, and NetworX control panels, zone type 25 is recommended.  

 

For Ultrasync control panels, set the sensor type to “Event Only”  

4) 

Take  note that  the  command  button automatically  ends  the enrollment mode  after 15  seconds of 

not  sending any commands  (i.e. after pressing and holding for 10 seconds and verifying enrollment is 

enabled with the 5 LED flashes, if the button isn’t pressed for 15 seconds immediately after the enrollment 

mode  activation,  it will revert back to  its normal operation of sending open + automatic restorals on button 

presses vs sending tampers). Depending on how long it takes to set up  each zone on  the panel  after a 

zone is learned in, you  may  need  to re-enter enrollment mode  again (holding down for 10 seconds) when 

ready  to enroll zones 2 and  3. 

Operating Instructions 

Each of the Command Button’s three different command configurations (Single tap, double tap, & press 

and  hold) can be used as the  initiating action to trigger a pre-configured scene, automation, or other smart 

device(s). 

To learn how to set up scenes/automations, refer to the instructions provided by the panel’s 

interactive services provider. 

Briefly tap the button once to trigger an 

“OPEN” transmission for zone #1.

 The red LED will flash 

once, and  then  re-illuminate, staying illuminated for approximately 3 seconds. During this continual 

illumination period, the sensor is sending an automatic restoral transmission. Wait until the LED l ight is no 

longer illuminated to send another command.   

Double tapping the button will trigger an “OPEN” transmission for zone #2

. The red LED will flash 

twice, and  then  re--illuminate, staying illuminated for approximately 3 seconds. During this continual 

illumination period, the sensor is sending an automatic restoral transmission. Wait until the LED light is no 

longer illuminated to send another command. 

Press  and hold the button for approximately 3 

seconds to trigger an “OPEN” transmission for 

zone #3

. The red LED will flash three times, and then re-illuminate, staying illuminated for approximately  3 

seconds. During this continual illumination period, the

 

sensor is sending an automatic restoral 

transmission. Wait until the LED light is no longer illuminated to send another command. 

Mounting 

Included with  this device is one piece of  double sided tape  for permanently  securing the Command Button 

in a desired location. Choose a suitable location for the sensor by  following the procedure in section 

“Testing the Sensor” ensuring desired signal strength is achieved. 

Where possible, install sensors within 100 ft. (30 m) of the panel.  While a transmitter may  have  an open-

air range of 500 ft. (150 m) or more, the environment  at the  installation site may have  a  signi ficant effect 

on operational  range. Changing a sensor location may improve wireless communication. 

 For reliable bonding, ensure the surface is clean and dry. Apply the  tape to  the backside  of the  sensor, 

and  then to  the desired location. Apply  firm pressure for several seconds. When mounting with double 

sided tape,  ensure temperatures are above  50°F and will remain above  50°F for at least 24  hours to 

ensure proper bond.  After 24 hours, the bond  will hold at lower temperatures. 

Sensor Testing (Test  before permanently mounting, as w ell as w eekly) 

The sensor test verifies proper communication between  the  sensor and the  panel/receiver. To test the 

sensor, refer to the specific panel/receiver documentation  and do  the following: 

1) 

Put the  panel/receiver into sensor test mode 

2) 

Press the Command Button  once 

– the sensor will then transmit a signal 

3) 

Listen for the siren beeps to  determine the  number of packets  received  (Each beep indicates 

one  packet  received, out  of 8 total). It is recommended  that  the panel  receives at least 5 out 

of 8  packets  from the desired sensor location. If the panel  is consistently receiving less than 

5 out  of 8 packets  from a  certain location, try rotating the sensor and/or relocating the sensor 

to an  area where it can achieve  better  communication.  

4) 

Exit  sensor test mode when  proper communication between  the sensor and  panel/receiver 

has been  verified.  

Replacing the Battery 

The Command  Button comes  pre-installed with a single Panasonic CR2032 Lithium coin-cell battery that 

provides 5  years of battery  life under normal usage conditions. When  the battery  is low, a signal will be 

sent to  the control panel. To replace the battery,  do  the following: 

1) 

Insert a small coin (such as a dime) into one of the  corner notches of the Command  Button 

and  twist to release the top  cover from the  bottom  cover.  

2) 

Set the  top cover  aside, and gently  remove  the circuit board from the bottom  case  

3) 

Flip the circuit board over, revealing the Panasonic CR2032 coin cell battery. Remove the 

battery  and  insert a new Panasonic CR2032 battery,  ensuring that the positive side (+) of 

the  battery  is facing towards the (+) sign indicated on the battery holder 

4) 

Place the circuit board back into the  bottom  case with the  battery  side facing down. Take 

note  that the  board will only fit properly into  the bottom  case in one  direction. On one side of 

the  middle of the  circuit board is a small notch. This notch should align with a small piece of 

plastic extending out from  the inside edge of the circuit board. When properly inserted, the 

circuit board will fit snugly and securely inside the bottom case. 

5) 

Replace the front cover  back  onto the  bottom  case.  

 

 

Reviews: