background image

 

© 2018 UTC Fire & Security Americas Corporation, Inc. 

1 / 4 

P/N 1069821 (ML) • REV E • ISS 23OCT18 

 

DC108 Series Magnetic Contact Installation 
Sheet 

EN  SV 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

EN: Installation Sheet 

Description 

The DC108 series are surface mounted magnetic contacts that 
can be connected to a burglar alarm system. The DC108 
series can be used on ferromagnetic and non-ferromagnetic 
environments and doors. For differences in the DC108 series 
see 

“Specifications” below. 

Mounting 

No special mounting tools are required. 

The magnetic contact and the magnet are to be mounted 
parallel to each other and with the text facing the same 
direction using screws. 

During installation the switching distances have to be 
individually determined for each contact. 

When the installation is completed, the electrical switch 
function of the magnetic contact must be checked (for 
example, with a continuity checker or multimeter). Use of 
mechanical force, for example when installing, can damage the 
glass body of the reed switches. 

Notes 

• 

The X direction bias is not certified for use on any type of 
material. See Figure 3. 

• 

When installing the contact please keep in mind that the 
doors can bend under temperature influence. 

UTC recommends to check regularly that the magnetic contact 
is working properly on the control panel and that the installers 
advise their customers to do this. 

Wiring description 

See Figure 2. 

 

Colour 

Description 

(1)  2X Silver, labeled as 

supervised loop 

Tamper, supervision line 

(2)  2X Silver 

Alarm, normally closed (DC108) 

(3)  2X Silver 

Alarm, normally closed (DC108R4.7) 

Package content 

• 

1X Magnetic contact 

• 

1X Magnet 

• 

4X Screws 

• 

2X Plugs 

Specifications 

Cable length 

2.5 m 

Switch close resistance: 
 

DC108 

 

DC108R4.7 

 
<2 

Ω 

4.7 kΩ ±10% 

Switch open resistance: 
 

DC108 

 

DC108R4.7 

 
>10 MΩ 
9.4 kΩ ±10% 

Mounted on non-ferromagnetic material

 

Approach distance Y (switch close) 

74 mm ±30% 

Removal distance Y (switch open) 

81 mm ±25% 

Approach distance Z (switch close) 

95 mm ±30% 

Removal distance Z (switch open) 

100 mm ±30% 

2

50.8 m

 in.

3.5 in.

88.9 mm

1.5

38.1 mm

 in.

0.43

11 mm

 in.

2.25

57.1 mm

 in.

1.5

38.1 mm

 in.

4K7

(1)

(2)

(3)

4K7

Y

Z

X

 

Reviews: