background image

 

© 2019 UTC Fire & Security Americas Corporation, Inc. 

1 / 2 

P/N 146489999-

1 • REV C • ISS 09JUL19 

 

ATS1831/32 IUM Modules Installation Sheet 

Figure 1: ATS1832 8 MB IUM module 

 

Description 

The intelligent user memory (IUM) module is an optional 
memory expansion component that works with the Advisor 
Master system. Two models are available: ATS1831 (4 MB) 
and ATS1832 (8 MB). 

Table 1: Advisor Master system capacities with IUM modules 

User records (cards) 
 

ATS1831 

 

ATS1832 

 
17,873/15,000 
65,535/55,000 

Users with PIN code (4 to 10 digits) 

All users 

Users names (max. 16 characters) 

Users 1 to 200 

Card data formats 

Up to 48-bit 

Programmable alarm groups 

128 

Door groups 

128 

Floor groups 

64 

Time zones 

24 

Alarm events buffer 

1,000 

Access events buffer 

1,000/5,000/10,000* 

* Applies to a control panel where ATS1831 can support 5,000 and 
ATS1832 can support 10,000 access events. In all other cases 1,000 
access events are supported. 

Installation 

WARNING: 

A qualified service person, complying with all 

applicable codes, should perform all required hardware 
installation. 

IUM modules are plugged into a control panel PCB and any of 
the panel’s intelligent four-door/four-lift controller PCBs to 
increase system capacity. The control panel and any intelligent 
four-door/four-lift controller must use memory expansion 
modules of the same capacity. 

Cautions 

• 

When installing an IUM module onto a control panel, the 
existing records for users, door groups, and floor groups 
are erased from the control panel’s memory. You must 
back up these records (if required) and reprogram them 
into the control panel after installing the module. 

• 

Take static preventative measures during installation. 
A conductive wrist strap should be worn and connected to 
a 0 

V terminal (e.g. “Batt−” or “Aux Pwr−”). If a wrist strap 

is unavailable, touch the 0 V terminal before installing, and 
then avoid touching the pins of the chip. 

Note the alignment notch on one end of the module. 

To install the IUM module: 

1.  Disconnect the plug pack and battery from the control 

panel or intelligent four-door/four-lift controller. 

2.  Carefully remove the module from its packaging, taking 

extreme care that none of the pins are bent. 

3.  Note the orientation of the module. The module has a 

notch, which corresponds with a notch on the IC socket. 

If the IC socket is already fitted with a memory expansion 
module, you must remove the module so that you can 
insert the IUM module in its place. 

4.  With the notch on the module aligned with the notch on 

the IC socket, carefully insert the module into the socket 
marked “RAM/IUM” making sure that no pins are bent 
under. 

5.  Gently press the module into the socket until all of the pins 

sit firmly in the socket. 

6. 

Clear the panel’s memory by shorting the KILL jumper for 
a minimum of 30 seconds (refer to installation guides for 
details). 

7.  Reapply power to the control panel or intelligent four-

door/four-lift controller. 

Regulatory information 

Manufacturer 

PLACED ON THE MARKET BY: 
UTC Fire & Security Americas Corporation, Inc. 
3211 Progress Drive, Lincolnton, NC, 28092, USA 

AUTHORIZED EU REPRESENTATIVE: 
UTC Fire & Security B.V. 
Kelvinstraat 7, 6003 DH Weert, Netherlands 

 

Reviews: