![Interlogix ATS125 Programming Manual Download Page 25](http://html.mh-extra.com/html/interlogix/ats125/ats125_programming-manual_2077288025.webp)
ATS125x/1260 Four-Door/Four-Lift DGP Programming Guide
19
OUT reader requires card and PIN
XX, NO - Out Reader Card & PIN
*-Change
Specify what method is required to open the door from the OUT reader. This is
programmed separately for the IN and OUT readers.
• Yes: Unlock the door by presenting a valid card to the reader
and
entering a
PIN on the reader’s keypad.
• No: Unlock the door by presenting a valid card to the reader
or
a valid PIN on
the reader’s keypad.
IN reader inhibit PIN if timezone
XX, NO - In Reader No PIN If TZ
*-Change
This menu determines which method is used to open the door during the
low
security timezone
and is programmed separately for the IN and OUT readers.
• Yes: During the Low security timezone, ONLY a valid card is required.
• No: During the Low security timezone, a valid card
OR
a valid PIN is required.
OUT reader inhibit PIN if timezone
XX, NO - Out Reader No PIN If TZ
*-Change
This menu determines which method is used to open the door during the
low
security timezone
and is programmed separately for the IN and OUT readers.
• Yes: During the Low security timezone, ONLY a valid card is required.
• No: During the Low security timezone, a valid card OR a valid PIN is required.
IN reader inhibit region 0 user
XX, NO-In reader Inhibit Region 0 Users
*-Change
For users in region 0 (region 0, on most occasions is outside), a special security
feature is available to provide access only via another region.
• Yes: Any user in region 0 will be denied access. To access, the user first has
to be in another region.
• No: Users from region 0 will gain access.