12
ATS125x/1260 Four-Door/Four-Lift DGP Programming Guide
Table 1: Reader Function
IN
IN
OUT
OUT
1
st
door
1
5
9
13
2
nd
door
2
6
10
14
3
rd
door
3
7
11
15
4
th
door
4
8
12
16
The RASes listed above are polled by ATS125x/1260.
Note:
RAS numbers followed by
‘,’ are online, RAS numbers followed by ‘:’ are
offline.
LCD RAS
No RAS with LCD’s Fitted
RAS with LCD
Program the address of RASes (arming stations) being polled that have a LCD
(Liquid Crystal Display) fitted - for example, ATS110x series LCD RAS.
The display shows the RASes currently recorded.
RASes with RTE enabled
No RAS’s with Request To Exit Enabled
RAS With RTE
Enter the address of RASes (arming stations) being polled that require the
Request To Exit button to be wired to the IN, or REQUEST TO EXIT, terminal on
the arming station.
The display shows the RASes currently recorded.
Note:
Since the RAS RTE input does not provide tamper monitoring, it is
preferable to wire any Request To Exit buttons to zones on ATS125x.
RASes with toggle mode
No RAS with Toggle Enabled
Toggle RAS:
Records the address of RASes (arming stations) being polled that have "Toggle
mode" enabled. Operation
for the ‘Toggle Mode’ is explained below. This option
only applies to RASes that have keypads and are connected to the ATS125x
local databus (ATS110x, ATS115x).
Toggle mode enabled:
• PIN + [ENTER] or [#] = Toggles status of areas
• PIN + [MENU*] or [*] = Toggles status of areas
Toggle mode disabled:
• PIN + [ENTER] or [#] = Arms areas