background image

 

© 2018 UTC Fire & Security Americas Corporation, Inc.  

1 / 4 

P/N 466-2979 (EN-FR) 

• REV A • ISS 24APR18 

All rights reserved. 

 

AS280 Indoor Siren Installation Sheet 

EN 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

EN: Installation Sheet 

Description 

AS280 is a high performance certified internal sounder for 
industrial / commercial applications and any situation where a 
high performance internal sounder is required. 

• 

Nominal siren output 116 (±2) dB(A) @ 1 metre. 

• 

Silent power up. 

• 

Positive ‘hold off’ trigger command. 

• 

Selectable cut off timer, 15 or 30 min plus 5 second test 
mode. 

• 

Battery protected against deep discharge. 

• 

Opening and removal from mounting tamper protection. 

• 

Tamper signalling via volt free contacts. 

• 

Auto reset fuse protection for battery circuit.  

• 

Designed to comply with EN50131-4: 2009. Grade: 2. 
Environmental Class: II. 

• 

Battery deep discharge protection 

– to prevent permanent 

damage. The sounder stops functioning automatically 
when the voltage falls under 9.5 Volts  

• 

Re-arming Sounder: After triggering the sounder can only 
be re-triggered if  +BL is taken to +12 V, before again 
taking to 0 V. An NP2.1 or PS-1221 battery provides 3 
operations of 30 minutes at a normal acoustic volume.  

Connections 

Terminal 

Description 

  Terminal  Description 

+ ALIM 

+14.3 VDC 

  Batt+ 

+ Battery (RED CABLE) 

0V ALIM 

0 V 

  Batt- 

- Battery (BLACK CABLE) 

+ BL 

+ Hold off 
(transition to 0 V 
will trigger the 
sounder). 

  AP 

Tamper contact 
Closed contact = normal 
Open contact  = Tamper 
(opening or removal from 
mounting) 

OUI

NON

 

 

(2) 

 

(1) 

Summary of Contents for AS280

Page 1: ...amper signalling via volt free contacts Auto reset fuse protection for battery circuit Designed to comply with EN50131 4 2009 Grade 2 Environmental Class II Battery deep discharge protection to prevent permanent damage The sounder stops functioning automatically when the voltage falls under 9 5 Volts Re arming Sounder After triggering the sounder can only be re triggered if BL is taken to 12 V bef...

Page 2: ...ake sure the tamper is not activated closed contact IMPORTANT The jumper must be placed for a maximum duration of 30 min IMPORTANT The battery must be a NP2 1 or PS 1221 Dispose of used batteries in accordance with all national and local regulations Specifications Sound output 116 2 dBA à 1 m Operating voltage 9 15 VDC Voltage ALIM 14 3 VDC Maximum supply voltage ripple 350mV Max current ALIM 100 ...

Page 3: ...tection de la batterie contre une décharge excessive Autoprotection à l ouverture et à l arrachement Autoprotection par contact N F libre de potentiel Protection du circuit batterie par fusible à réarmement automatique Protection contre décharge totale de la batterie pour éviter de l endommager définitivement La sirène arrête automatiquement de fonctionner quand la tension tombe sous 9 5 Volts Pri...

Page 4: ... 7 6003 DH Weert Pays Bas Avertissements et avis de non responsabilité CES PRODUITS SONT DESTINÉS À DES PROFESSIONNELS EXPÉRIMENTÉS QUI DOIVENT ÉGALEMENT SE CHARGER DE LEUR INSTALLATION UTC FIRE SECURITY NE PEUT GARANTIR QU UNE PERSONNE OU ENTITÉ FAISANT L ACQUISITION DE CEUX CI Y COMPRIS UN REVENDEUR AGRÉÉ DISPOSE DE LA FORMATION OU DE L EXPÉRIENCE REQUISE POUR PROCÉDER À CETTE MÊME INSTALLATION ...