background image

inside this appliance.
Do not use any electrical appliances inside the refrigerated compartment of this appliance. 
Do not use any mechanical devices or other means to accelerate the defrosting process.
Defrosting is performed automatically by the electronic controller and needs no user
intervention.

the insulation foam. As such it is mandatory that the cabinet is serviced and, at

end-of-life, recycled by a professional organisation and skilled persons who have 

consult your Local Authority or contact Interlevin.
The appliance uses LED lighting. The lighting strips and transformer should only be

During all operations, please be careful not to jolt, jar, bump or thump the cabinet. 
Handle it gently and with care. The refrigeration pipework is delicate and will be 

damaged by rough handling.

Do not exceed the maximum shelf loading weight of 25 kgs per shelf so as to avoid 
injury or damage.
Never move or tilt the appliance whilst the power switch is in the “ON” position.

Do not damage the refrigeration circuit. If you do so, then open a window or door

The appliance must always be earthed.

1

.

2

  

Unpacking and positioning (before connecting to the power supply)

During all operations, please be careful not to jolt, jar, bump or thump the cabinet. 
Handle it gently and with care. The refrigeration pipework is delicate and will be 
damaged by rough handling.
The appliance is heavy and therefore please carry out a risk assessment prior to 
beginning this operation.
Please cut the banding straps taking the necessary precautions to avoid hurting 
yourself or others. Remove all of the packaging and ensure that it is recycled in 

The appliance must only be charged with R600a refrigerant from an authorised supplier. 
To use another type of refrigerant would be dangerous and is not permitted under any 
circumstances.

Electrical equipment should not be placed under the unit or where refrigerant could 

gather in the event of a leak.
If it is necessary to repair the refrigeration such that it needs to be opened or charged,
then it will be necessary for the technician to possess a Gas Work Authorisation 

(hydrocarbon refrigerants). Queensland, Australia has particular regulations for such 

activities.

The electrical wiring diagram is to be found on the appliance itself and is located inside 

 
the cabinet on the side wall.

4

replaced

 

using

 

genuine

 

Interlevin

 

parts

 

of

 

the

 

same

 

technical

 

specification

.

Summary of Contents for EC10H

Page 1: ...20 H S HSS PD30 H S HSS EC10H EC20 H S EC30H Interlevin Refrigeration Ltd West Meadow Rise Castle Donington Derby DE74 2HL Sales 01332 850090 Parts 01332 850190 Service 01332 850064 Email trade sales interlevin co uk Web www interlevin co uk Uploaded Jan 2016 ...

Page 2: ...ance routines Failure to observe the instructions is unsafe and will also invalidate the guarantee the booklet in a safe place for your future reference The booklet contains mandatory safety information as well as WARNING Any refrigeration repair or any electrical work must only be 1 PD10H PD20H PD20S PD30H PD30S EC10H EC20H EC20S EC30H EC30S PD10H SS PD20H SS PD30H SS ...

Page 3: ...ower supply 4 5 1 3 Connecting the cooler to the Power Supply 6 2 0 OPERATION 2 1 Operation of the Appliance 6 2 2 Adjustment of the temperature 6 3 0 MAINTENANCE 3 1 Lighting 7 3 2 Cleaning the interior and exterior 7 3 3 Cleaning the Condenser 7 4 0 IN THE EVENT OF A MALFUNCTION 8 5 0 DISPOSAL AT END OF LIFE 8 6 0 CONTACTS 8 2 ...

Page 4: ...dren without supervision Do not cover the front grille or rear air vents and please observe the installation and setting up instructions described later in this manual Adequate ventilation must be ensured for the appliance Keep clear of obstruction all ventilation openings in the appliance enclosure Do not probe any openings in the cabinet and be careful not to touch any moving parts such as the f...

Page 5: ... Unpacking and positioning before connecting to the power supply During all operations please be careful not to jolt jar bump or thump the cabinet Handle it gently and with care The refrigeration pipework is delicate and will be damaged by rough handling The appliance is heavy and therefore please carry out a risk assessment prior to beginning this operation Please cut the banding straps taking th...

Page 6: ...nsulted malfunctions may occur including but not limited to the condensate water not draining away and the doors not functioning correctly You may adjust the appliance using the The appliance requires a minimum ventilation space at sides top and rear of 20mm The front grille must be completely unobstructed See Figure 2 Figure 2 accordance with all local laws and regulations Safety Note Please pay ...

Page 7: ...set to chill the beverages to approximately 2 Centigrade Should you wish to alter the set point please adopt the following procedure 2 0 OPERATION 2 1 Operation of the Appliance 2 2 Adjustment of the temperature Press and hold for 4 seconds to enter the menu DEF To activate a manual defrost press this button UP Increases the parameter value DOWN Decreases the parameter value Step 1 Press and hold ...

Page 8: ...ning the Condenser This appliance has a low maintenance condenser that is less prone to blockage than other types However it is still recommended to check that it is clean and dust free at least every three months Please adopt the following procedure or go to www cleanme eu for a demonstration enclosure Unplug from the mains power supply Step 2 Looking at the back of the appliance remove the screw...

Page 9: ... compartment It is often accompanied by or located next also within the insulation foam It must be recycled by a professional competent authorised and regulated organisation with expertise in the handling of refrigeration appliances For further information please 5 0 DISPOSAL AT END OF LIFE For further information or to obtain Genuine Spare Parts please contact Interlevin Refrigeration Ltd West Me...

Reviews: