Inter-m NLM-8000C Manual Download Page 1

NLM-8000C

Local Machine

Rear Panel

Features

This device is a wall controller that used by connect-

ing with MR-8000 mounted on NPX-8000. It can se-

lect the sound source and volume, and can expand

up to eight in the mode of Daisy Chain.

Front Panel

3

2

1

OUTPUT 1

INPUT 1   

INPUT 2               

INPUT 3  

INPU      

IN

N

  

   

   

   

   

 

I

    

LM LINK

LM LINK

2

1

1. Displaying Window

Sound source, volume, and status information of the

channel set at NPX-8000 are displayed.

2. Selecting Switch

It is a switch that can change the sound source and

volume, and select the status information.

It is selected if the switch is turned to control the

value you want and press the switch at the position

to select.

3. Led Status Displaying Led

It is LED that displays the operation status of the device.

- Channel mode: GREEN LED is on.

- Volume mode: BLUE LED is on.

- Sleep mode: When Led Control is ON, BLUE LED

is on. When Led Control is OFF, LED is off.

In case Led Control is OFF, LED turns off.

- Communication error: RED LED is on.

- Setup mode: MAGENTA LED is on.

- Others: RED LED is on at Mute status.

1. Termination Switch

It is a switch used in the device connected finally in

case of connecting the device using LM port of MR-

8000 by Daisy Chain mode.

2. Lm Link Port

It  is  the  terminal  that  can  connect  power  supply

(+40V) and communication, audio line.

※ Be sure to use direct cable when connecting LINK 

of device.

※ For cables, it is recommend to use those below 

DCR 100m/9.8Ω.

NO

Description

1

CAN – H

2

CAN - L

3

N.C

4

DC 40V

5

GND

6

N.C

7

Audio Out+

8

Audio Out-

<RJ45 Terminal Description>

Summary of Contents for NLM-8000C

Page 1: ...elect 3 Led Status Displaying Led It is LED that displays the operation status of the device Channel mode GREEN LED is on Volume mode BLUE LED is on Sleep mode When Led Control is ON BLUE LED is on When Led Control is OFF LED is off In case Led Control is OFF LED turns off Communication error RED LED is on Setup mode MAGENTA LED is on Others RED LED is on at Mute status 1 Termination Switch It is ...

Page 2: ...nnect NPX 8000 and NLM 8000C power is supplied to NLM 8000C and NLM 8000C is ON 2 In case ID of NLM 8000C collides ID set window is displayed In this case ID is reset Refer to 2 Device set explanation or MP 8000 manual for ID set 3 In case NLM 8000C was connected with the de vice normally in case it is not communicated LINK ERROR is displayed In this case check communication status cable etc again...

Page 3: ... the present Volume is increased and it can change up to 100 at largest 4 If the selection switch is pressed the present Volume is Muted When it is Muted Mute phrase is displayed at the center of the screen and when controlling the Volume Mute phrase is displayed at the left bottom 5 If the selection switch is pressed again Mute is cancelled On the Channel or Setting screen Mute cannot be set with...

Page 4: ...thout pre notice No 140523 2017 5 RJ 45 RJ 45 Push Encoder STATUS LED DC DC CAN DRIVER MCU OLED DISPLAY 1 3 inch Block Diagram application 120 240V 50 60Hz 30W AC INPUT DC 24V RS 232C MONITOR OUT 8 7 6 5 4 3 2 1 G G RX TX CONTACT OUTPUT 8 7 6 5 4 3 2 1 CONTACT INPUT POWER ON OFF MUTE EXT B A CH8 CH7 CH6 CH5 CH4 CH3 CH2 CH1 AUDIO OUTPUT G G G G G G G G AUDIO INPUT CH8 CH7 CH6 CH5 CH4 CH3 CH2 CH1 G ...

Reviews: