7

 

Alarm

X

            show the status of gray alarm 

N/Y 

                                      N: off

;(

Default

      Y: On 

8

 

E

X

                    Show the status of image enhancement

setup as C/1/2

 

                                          C: Close

;(

default

      1/2

Open relatively Gain grade   

9

 

Backup

              factory default 

including auto

polarity

alarm range

calibration

image

alarm

alarm pixel Number

 

10

 

Exit 

XXX

        press key “FOCUS+” or “FOCUS-” to exit 

 

 

 

3.3 COM sub-menu   

First

:;

Without the menu call preset 100. Enter the main menu. In the main menu, press the key “LENS- 

“move the cursor to “setup” 

press key “FOCUS+” or “FOCUS-” show the password dialogue

Input the 

password. “FOCUS+

FOCUS-

FOCUS+

FOCUS-

FOCUS+

FOCUS-” enter the sub menu   

Second

  After login Sub-menu. press the key “LENS- “move the cursor to “COM” key. press key “FOCUS+” 

or “FOCUS-” show the password dialogue

Input the password. “FOCUS+

FOCUS-

FOCUS+

FOCUS-

FOCUS+

FOCUS-” enter the level 3 sub menu. Refer to Pic 4   

 

 

 

 

 

 

Summary of Contents for ThermalTronix TT-1009L-UTCM

Page 1: ...ThermalTronix TT L UTCM Series Thermal Imaging Camera User Manual...

Page 2: ...If the internal connection is broken during the assembly process or the apparatus is damped rain wet the performance will be reduced and even the device will be damaged Make sure that the power contro...

Page 3: ...4 2 1 Interface definitions 4 2 2 Dimensions 5 2 3 Protocol setup 6 2 4 Function key chart 6 2 5 Guide for call the Preset 6 3 Operations 7 3 1 Main menu 7 3 2 Sub menu operations 9 3 3 COM sub menu...

Page 4: ...interface support PELCO D PELCO P protocol Thermalized focus free lens Multiple lens options 9mm 18mm 37mm 50mm 1 2 Applications Road monitoring perimeter guard channel management marine reconnaissan...

Page 5: ...4 2 Appearance 2 1 Interface definitions Back View...

Page 6: ...Note 1 Video Analog video 2 GND Video GND 3 RS485 RS485B 4 RS485 RS485A 5 ALARM Alarm switch output Open 6 ALARM Alarm switch output 7 GND Power GND 8 DC 12V DC12V input 2 2 Dimensions Product outsid...

Page 7: ...for call the Preset A call preset to popup the menu Call preset 100 popup menus and press key LENS to change the items B call preset to setup the alarm range Call preset 101 to switch the alarm range...

Page 8: ...l preset to change the address of thermal camera Call preset 111 to changes to address 1 Call preset 112 to changes to address 2 Call preset 113 to changes to address 13 Call preset 127 to changes to...

Page 9: ...XXX Gain value range 1 1023 3 B XXX Brightness value range 4 P XXX White black hot display mode 0 black hot 1 white hot 5 ZOOM Y N Zoom status N no zoom default Y Zoom 2 times 6 Level X show the level...

Page 10: ...e main menu move the cursor to Settings option press Focus or Focus show the password dialogue Input the password refer to Pic 2 Press key FOCUS FOCUS FOCUS FOCUS FOCUS FOCUS to enter refer to Pic 3 P...

Page 11: ...US FOCUS FOCUS enter the level 3 sub menu 5 Recover H L N Setup as H L N Setup as H Calibrate 1 time during the 1 minute if working time less than 10 minutes Calibrate 1 time during 2 minutes if worki...

Page 12: ...or FOCUS to exit 3 3 COM sub menu First Without the menu call preset 100 Enter the main menu In the main menu press the key LENS move the cursor to setup press key FOCUS or FOCUS show the password dia...

Page 13: ...Rate XXX Baud 1200 2400 4800 9600 14400 19200 38400 3 Protocol PELCO D P 4 Exit Press key LENS to exit Default Add 1 Baud 2400 Protocol PELCO D 3 4 Mode sub menu First Without the menu call preset 100...

Page 14: ...show the password dialogue Input the password FOCUS FOCUS FOCUS FOCUS FOCUS FOCUS enter the level 3 sub menu Refer to Pic 5 In the menu Mode Press key LENS move the cursor Press key FOCUS or FOCUS to...

Page 15: ...e sub menu Second After login Sub menu press the key LENS move the cursor to Alarm Valve key press key FOCUS or FOCUS show the password dialogue Input the password FOCUS FOCUS FOCUS FOCUS FOCUS FOCUS...

Page 16: ...t Alarm range and alarm valve grade 1 650 relatively temperature difference is 30 Grade 2 1050 relatively temperature difference is 45 Grade 3 1450 relatively temperature difference is 60 Grade 4 2100...

Page 17: ...23m NETD 100mK Gain Brightness adjustment Manual brightness gain auto brightness manual gain auto brightness gain Functions Polarity inversion White black hot mode Digital zoom 2X Calibration Automati...

Page 18: ...not power on Power cable is not connected correctly Connect the power cable again Thermal camera protection procedure Wait for 5 seconds and turn on again The camera powers off automatically The power...