4.2.6 Network configuration
1) Network port
Data port:
set the data port, the device will restart automatically after changed (default 3000, 0-65535 optional).
Web Port
: Set Web port, the device will restart automatically after changed (default is 80, 0-65535 is optional).
Onvif Port
: Set Onvif port, the device will restart automatically after changed (default 2000, 0-65535 optional).
Soap Port
: Set Soap port (default 1936, 0-65535 optional).
RTMP Port:
Set RTMP port (default 1935, 0-65535 optional).
RTSP Port
: Set RTSP port, the device will restart automatically after changed (default 554, 0-65535 optional).
Visca Port
: Set Visca port, the device will restart automatically after changed (default 3001, 0-65535 optional).
Click on the "Save" button, it will be valid when display "Save successful".
RTMP Obtaining method: rtmp: // device IP address: 1935 / live / av0 (av0 main stream; av1 secondary stream)
2) Ethernet parameters
DHCP:
Enable or disable obtain IP automatically can be set. Save changes and reboot the device to takes effect (Default:
OFF)
IP Address:
Set the IP address, save changes and reboot the device to takes effect (default 192.168.5.163).Note: This IP
address is the same with the one used to login Web page.
Subnet Mask:
Set the subnet mask (default 255.255.5.0).
Default Gateway
: Set the default gateway (default 0.0.0.0).
Physical Address
: Set the physical address (the parameter is read-only but cannot be modified).
Click on the "Save" button, it will be valid when display "Save successful". (Note: To prevent IP conflicts When modify).
3) DNS parameters
Preferred DNS server: set the preferred DNS server. (Default 0.0.0.0).
Alternate DNS server: Alternate DNS server settings. (Default 0.0.0.0).
Click on the "Save" button, it will be valid when display "Save successful".
4) GB28181
Switch: set whether open GB28181, can check
Time Synchronization: whether synchronization time is set, you can check
Stream Type: stream type setting (the default main stream, secondary stream optional)
Sign effective time (in seconds): 3600 Range 5-65535
Heartbeat time (seconds): 60 Range 1-65535
Register ID: 34020000001320000001
Register User name: IPC
Register Password: 12345678
Equipment ownership: Users can add their own
Administrative regions: Users can add their own
Alarm Zone: Users can add their own
Equipment installation address: Users can add their own
Local SIP Port: 5060 Range 0-65535
GB28181 Server Address: IP address of the computer
Server SIP Port: 5060 Range 0-65535
Server ID: 34020000002000000001
Click on the "Save" button, it will be valid when display "Save successful".
4.2.7 System configuration
1) Device Properties
Device Name: Set the device name (the default Camera1, user can add their own).
Device ID: Set the device ID (default 1, Read-Only).
System Language: Set the system language (default Simplified Chinese, English optional).Need to re-login after modify
and save the setting.
Click on the "Save" button, it will be valid when display "Save successful".
2) System Time
Date Format:
Set the date format (YYYY-MM-DD default that year - month - day, MM-DD-YYYY namely Month - Day -
Yard-MM-YYYY date - month - year Optional).
Date separator
: set the date separator (default '/','.','-' Optional).
Time Zone:
Set the time zone (default east eight districts, other time zones optional).
Time Type:
Set the time types (default 24 hours, optional 12 hours).
NTP Enable
: click it to set NTP time.