Intellisystem IT-400-IPC Series User Manual Download Page 1

 

 

IT-400-IPC Series 

IP Camera Tester 

User  Manual 

V01.00

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for IT-400-IPC Series

Page 1: ...IT 400 IPC Series IP Camera Tester User Manual V01 00...

Page 2: ...read the Safety Information carefully in the manual The manual should be kept well in case of reference Keep the S N label for after sale service within warranty period Product without S N label will...

Page 3: ...era connection 11 3 2 3 HD Coaxial camera connection 11 3 2 4 HDMI IN Optional 13 3 3 OSD menu 13 3 3 1 Lite mode Normal mode 13 3 3 2 Drop down Menu 17 3 3 3 Short cut menu 18 3 3 4 Screen capture 19...

Page 4: ...ower DC12V 2A and DC 5V 2A USB power output 70 3 3 20 Cable Test 72 3 3 21 RJ45 cable TDR test 73 3 3 22 Cable Search Optional 76 3 3 23 TDR cable test Optional 77 3 3 24 PoE voltage and power measure...

Page 5: ...System Setting 104 3 3 42 File explorer 108 3 3 43 Theme 110 3 4 Audio test 112 3 5 PoE power output 113 3 7 DC12V 2A power output 114 4 Specifications 116 4 1 General Specifications 116 4 2 Multi met...

Page 6: ...le gas Do not disassemble the instrument since no component inside can be repaired by the user If the disassembly is necessary indeed please contact with the technician of our company The instrument s...

Page 7: ...AHD SDI cameras as well as testing 4K H 264 4k H 265 camera by mainstream The 960x540 resolution enables it to display network HD cameras and analog cameras in high resolution The unit supports many...

Page 8: ...4V DC 5000mAh 5 BNC cable 6 RS485 cable 7 SC ST Connector Only for optical power meter 8 Multi meter test leads one pair of red and black only for the Multi meter models 9 Output Power cable 10 Audio...

Page 9: ...4 2 3 Function interface...

Page 10: ...s of the menu close or decrease the aperture 1 0 Upward set function or add parameter Tilt the PTZ upward 1 1 Rightward select the parameter whose value will be changed Add the value of the parameter...

Page 11: ...data accepted indicator it lights red while the data is being received 2 2 The RS485 RS232 data transmission indicator it lights red while the data is being transmitted 2 3 The charge indicator it lig...

Page 12: ...TDR cable test interface 2 8 LED lamp 2 9 SDI input BNC interface Optional 3 0 HDMI input 3 1 Video image signal output BNC interface cable tracer interface Optional 3 2 Video image signal input BNC...

Page 13: ...r LAN test port Use to test PoE or non PoE IP camera 3 Operation 3 1 Installing the Battery The tester has built in lithium ion polymer rechargeable battery The battery cable inside battery cabin shou...

Page 14: ...pen must insert the corresponding port Warnings Instrument communication port is not permitted access circuit voltage over 6V otherwise damage the tester Warnings Not allow insert multi meter pen in...

Page 15: ...PoE power supply the PoE switch and the power sourcing equipment are allowed to connect to the tester s PSE port and the PoE power will be supplied to the IP camera by the tester s LAN port On this co...

Page 16: ...e image display on the tester and monitor 3 Connect the camera or the speed dome RS485 controller cable to the tester RS485 interface Note positive and negative connection of the cable Support RS232 P...

Page 17: ...will display on the tester The tester only come with SDI input interface There is no SDI output interface 2 Connect the SDI camera or the speed dome RS485 controller cable to the tester RS485 interfa...

Page 18: ...3 OSD menu Press the key 2 seconds to turn on Press the key 2 seconds to turn off short press the key to enter sleep mode press it again to test if tester work abnormally and cannot be turned off Pre...

Page 19: ...al seconds can move the icon to other apps In lite mode click the finger icon in the lower right corner to release lock icon move icons and change function icons sequence Normal mode Tap the screen an...

Page 20: ...icon several seconds go screen management status Change icons sequence and move it to common tools bar You can move the icon to any pages self define the number of icons in any page Make interface sa...

Page 21: ...r enter the folder name Icon will be auto placed in the new named folder Press the folder several seconds to change the folder name you can move the icon out of folder the folder will be auto deleted...

Page 22: ...l or remove SD card 3 3 2 Drop down Menu Press and slide at right top right corner twice to open shortcut menu The shortcut menu includes POE power output IP settings Wi Fi HDMI IN CVBS Video OUT LAN...

Page 23: ...can test circuit and BNC cable whether normal LAN Display network port or WIFI connection real time upload and download speeds and other network parameters Brightness Set brightness Settings Enter se...

Page 24: ...st it will auto move to shortcut menu If delete any app in the short cut menu please select an app and press several seconds it will be deleted 3 3 4 Screen capture Long press the key enter can captur...

Page 25: ...elect TesterPlay app to enter click Start button to generates two dimensional code Please use mobile phone scan it then download and install the client software you can view the screen real time proje...

Page 26: ...21 3 3 6 Rapid video Press enter function one key to detect all network cameras and auto play the images...

Page 27: ...22 Auto log in and display camera image Detailed operation refer to ONVIF function After exit ONVIF app Click Refresh to search ip address...

Page 28: ...ay the camera s IP address if tester connects to Local Area Network it displays the current IP address Temp IIP After searching IP address the modified tester s IP address will not be saved if you do...

Page 29: ...ras name and IP address on the Left of screen Tester can auto login camera and display camera image Factory default use admin password to auto login if you modified the password then default use the m...

Page 30: ...n the Device List The tester will show the IP camera s relative information and settings Activate HIKVISION Camera When connected unactivated HIKVISION Camera tester can auto recognized And prompt The...

Page 31: ...ting IP Settings Advanced to add other network segments IP Rapid ONVIF function can across network segments to scan camera s IP Auto Login After open this function tester can auto login camera and dis...

Page 32: ...ONVIF to default settings Confirm Save the modified parameters Click MENU icon to open camera setting While in the Live video menu click Video Menu at the top right of the image to access the followi...

Page 33: ...mpatible IP PTZ cameras will rotate accordingly PTZ rotation direction is displayed on top left corner of the image IP camera video settings Click Video Set to enter the IP camera s encoder and resolu...

Page 34: ...29 Profiles Click profiles can view video streaming current configuration files as well as switch between Major stream and minor stream...

Page 35: ...Quickly preview and zoom in or out pictures automatically and manual refresh Identification click Identification to view information of the camera Time set click Time set Select Manual set to set up...

Page 36: ...reset or restore to factory settings User Set Modify camera user name password etc parameters Network setting Click Network Set to change the IP address Some cameras cannot support change IP address...

Page 37: ...ey to zoom out press upward and downward key to move image If it is network video input to the tester as the tester supports resolution up to 1080p the input image will be very clear after it is enlar...

Page 38: ...e the tester auto stores the files after snapshot Record When you click bottom the Record icon video starts recording A red recording icon appears on the screen and begins to flash and a timer appears...

Page 39: ...Video files can play in the Video player on the main menu PTZ Set preset position Move the camera to preset position enter the preset number on the Bottom right corner to complete position preset Call...

Page 40: ...TZ Speed set Horizontal and Vertical Speed set RTSP Get RTSP address of the current camera Doc Auto generate test reports document of camera click Create document Click Preview to view the report docu...

Page 41: ...ption the description of function icons on the bottom toolbar 3 3 9 IP camera test Display image from the 4K H 265 camera by mainstream Click icon to enter IP camera test Note Currently the IPC Test A...

Page 42: ...the IP Camera type to select the Manufacturer and model number of the integrated IP camera Manual Click IP camera type list Honeywell Kodak Tiandy Aipu waton ACTi WoshiDA IP camera etc If the brand ha...

Page 43: ...era s IP address It is better to directly connect the IP camera to the tester so the search results will only display the camera s IP address If the tester is connected to a PoE switch it will find an...

Page 44: ...ions 3 3 10 HDMI IN Optional HDMI in HD signal test Tap icon to enter When tester receives HDMI in image the top tool bar shows the resolution of this image You can select resolution to set resolution...

Page 45: ...s indicating the time elapsed for the video Click on the Record icon again to stop recording and save the video file to the SD card if select manual storage before recording begins appears dialog box...

Page 46: ...l photo to display it on the screen Double tap the image you want to view to make it full screen Double click again the photo to return To rename or delete an image click and hold on the file until th...

Page 47: ...ck the Playback icon to view your recorded videos Tap on the video file image you want to watch To rename or delete a video click and hold on the file until this screen appears Video files also can pl...

Page 48: ...level meter PEAK level SYNC level COLOR BURST measurement Select relative function on the right side Toolbar to operate functions including Photos Snapshot Record Playback PTZ Set Click or press to q...

Page 49: ...ddress E Pan speed Set the pan speed of PTZ camera 0 63 F Tilt speed Set the tilt speed of PTZ camera 0 63 G Set preset position Set PS Click and select Set PS set and save preset position number 1 12...

Page 50: ...olor saturation as well as the file storage way after snapshot and recording support auto storage and manual storage When select manual storage user can name and store the files 3 4 x zoom image displ...

Page 51: ...deo input as it supports resolution up to 960 540 the zoom in image is still very clear This is very helpful for IP camera installation 4 Snapshot Click the icon Snapshot when the video in to take a p...

Page 52: ...storage before recording begins appears dialog box Input Name user defined the files name by Chinese character English letter or digit to store in SD card tester will hereby store the files in SD car...

Page 53: ...n the file until this screen below appears 7 Recorded video playback Click the Playback icon to view your recorded videos Tap on the video file image you want to watch To rename or delete a video clic...

Page 54: ...sampling and processing technology can perform both NTSC and PAL video amplitude signal measurements for PEAK to PEAK SYNC levels and COLOR BURST chroma level When an analog signal is fed into the met...

Page 55: ...sh in amplitude over longer cable runs and can get fall below the threshold for the video display to show a color image For NTSC format the Chroma standard level is 40 IRE For PAL format the Chroma st...

Page 56: ...ar red green blue white or black Double click to full display on the screen and output click to return main menu Application BNC loop test Tester can send and receive color bar generator through the t...

Page 57: ...ster sends out the pure color bar such as white and black color to test the monitor whether has bright or black dots C The tester sends out video signal image to test if the image received by the moni...

Page 58: ...tor function please refer to the relevant instructions 3 3 1 in the manual Click or press to quit 3 3 14 CVI camera test Optional HD CVI camera CVI dome camera test and PTZ control click icon to enter...

Page 59: ...54 1 PTZ control 1 1 Coaxial PTZ control Click the icon PTZ on the right toolbar to do the corresponding setting Port select coaxial control...

Page 60: ...era or decoder then the IPC tester can test After setting the parameter the tester can control the PTZ and lens To control PTZ by screen touch Tap left right upward and downward on the touch screen to...

Page 61: ...anually Press the key manually adjust the zoom Set preset position Move the PTZ camera to the preset position the Tap it and input preset position number Tap Set position to complete set preset positi...

Page 62: ...Z control parameters setting 2 Coaxial camera menu setting Tap icon UTC select menu setting to enter the dome camera menu Input calling dome camera menu address code after finishing the parameter sett...

Page 63: ...58 Press arrow keys to set 3 Snapshot record photo viewer and video play back please refer to 3 3 1 PTZ 1 Video monitor test Tap close menu or press the key to close camera menu...

Page 64: ...storage user can name and store the files 3 3 15 TVI camera test Optional HD TVI camera TVI dome camera test and PTZ control Click icon to enter When HD TVI signal input the tester will display the im...

Page 65: ...P 30FPS 1920x1080P 50FPS 1920x1080P 60FPS 2048x1536P 18FPS 2048x1536P 25FPS 2048x1536P 30FPS 2560x1440P 15 FPS 2560x1440P 25 FPS 2560x1440P 30 FPS 2688x1520P 15FPS 2592x1944P 12 5FPS 2592x1944P 20FPS...

Page 66: ...e key or click the icon to call the dome camera menu More operation instructions such as PTZ control coaxial camera menu setting snapshot recording and playback etc please refer to 3 3 6 CVI camera te...

Page 67: ...80x720P 30FPS 1920x1080P 25FPS 1920x1080P 30FPS 2048x1536P 18FPS 2048x1536P 25FPS 2048x1536P 30FPS 2560x1440P 15 FPS 2560x1440P 25 FPS 2560x1440P 30 FPS 2592x1944P 12 5FPS 2592x1944P 20FPS 1 Coaxial P...

Page 68: ...the Port Number Scan to scan for open ports 2 PING Test Connect a network cable to the LAN port and click the icon to open the PING tool You can set your LOCAL native IP address Remote IP address e g...

Page 69: ...will be lost when test start 3 Network test Ethernet bandwidth test Network test Ethernet bandwidth test To use the Network tester you will need two IP testers One is used as a Server and the other as...

Page 70: ...be tested with a computer using compatible network bandwidth testing software Install network bandwidth testing software on a computer as a test Client or Server to do the mutual testing with the tes...

Page 71: ...66 Start to test network bandwidth Or use tester as a Server computer as test Client select Client input tester s IP address to test When use tester as Server shows results...

Page 72: ...re connected well the LAN port of POE switch flash at special frequency If not no any changes on the LAN port Application The tester will send special signals to make the connected LAN port flicker at...

Page 73: ...cameras and other networked devices Click the Refresh button to check your Client list 6 Trace route It is used to determine path of the IP packet access target Note Trace route testing results only f...

Page 74: ...s Click Add and enter the desired IP address To test different network segments click the Settings icon on the main menu and go to IP Settings and make the desired changes Once the desired IP addresse...

Page 75: ...le to tester s LAN port Press to enter Rapid IP Discovery app Click Start to search all IP address of connected equipments in whole network segment Click Stop to stop work 3 3 19 PoE power DC12V 2A an...

Page 76: ...r to avoid destroy 3 The IPC tester power output is close to 2A if the IP camera s power is over 2V the tester will auto enter protection mode Disconnect all the connections of the tester and then con...

Page 77: ...he sequence of wires as well as the serial number of the cable tester kit will be displayed The number of the cable tester is 255 If need several different number other types cable testers should pay...

Page 78: ...ne if not link up or open circuit screen display open circuit if cable pair is short circuit screen display short circuit Length The max test length is 180 meters when cable is open circuit or short c...

Page 79: ...reflectivity value is 0 it is the best quality communication Impedance After link up if the impedance value is 100 it is the best quality communication the range is generally in 85 135 Skew After 1000...

Page 80: ...75 Cable sequence diagram A straight through and cross over cable diagram the cable sequence display for reference Click Help check the instruction of all parameters...

Page 81: ...st the volume Note Install two AAA batteries in your blue Cable Identifier Note While the cable tracer is receiving the audio signal from the tester it may be induced into adjacent or crossing cables...

Page 82: ...d to any equipment otherwise it will damage the tester Connect Alligator clip cable to the TDR port and the cable must connect well before testing otherwise it will influence the accuracy Click to ent...

Page 83: ...Cable Type to select user defined 1 for calibration 11 groups user defined can be set 1 Select user defined and click Calibration to enter test click user defined 1 can define cable name such as AiPu...

Page 84: ...circuit or short circuit reflected pulse is generated the tester receives and deals with the reflected wave measurement results displayed on the screen TDR can test cable open circuit and short circui...

Page 85: ...node for this test to work Note The PoE switch must be connected to the PSE IN port The powered device such as IP camera or other PoE node must be connected to the LAN port Note Do not connect PoE po...

Page 86: ...rent adaptor input voltage and power Note the current 12V input measured power is the battery charging power and the device working power the measured power will change depending on the different of b...

Page 87: ...easuring AC DC Voltage and current measurement state display Auto range The Multimeter auto adjust the range by input signal or tested components Data hold Hold data Relative measurement Display the r...

Page 88: ...the AC voltage measurement C the tester default Auto range status by click AC auto range d Manual range can be select press the key NEAR to restore Auto range e Manual range 0 000V 6 600V range 00 00...

Page 89: ...imum current of 10A socket is 10A over current will destroy the meter and will damage the operator In AC mode only can input AC if not will damage the meter Resistance Measuring WARNING When measuring...

Page 90: ...e testing c Connect test red lead across to the anode the black lead to the cathode of the diode under testing d Connect test red lead across to the cathode the black lead to the anode of the diode un...

Page 91: ...oid electric shock be sure the capacitors have been discharged fully before measuring the ca pacitance of a capacitor c While testing the capacitance of a capacitor to 660uF the Max time will be 6 6 s...

Page 92: ...the current over the rated range fuse will melt to protect the meter Pls use the same model when change the fuse Pls opens the battery cover to change Note 10A socket without fuse protection if over t...

Page 93: ...ting set the wavelength for measurement Click relative difference to test the tester Auto save current fiber power value as the base reference value Input another optical fiber to be measured the disp...

Page 94: ...Optional Click icon to enter VFL four status can select Steady mode Evasive 1Hz Evasive 2Hz and Time off Click button Steady mode to enter steady status click button Evasive 1Hz and Evasive 2Hz to en...

Page 95: ...Hz to enter pulse mode the red laser source is emitted by a certain frequency press it again to quit 3 3 29 Audio Record Connect an audio device to the IP tester s audio input port Click the icon to e...

Page 96: ...D if not like P While the tester receives the code press the key to empty Though the RS485 port display the PTZ control code of the multifunctional keyboard or the DVR Controller can check the status...

Page 97: ...eo formats of MP4 H 264 MPEG4 and MKV The IP tester recorded files can play directly via the Media player The Media player will automatically display the video files from the SD card Click on the desi...

Page 98: ...live video From the main menu select the APP Tool folder and then select the RTSP Player to open the app If the IP camera uses MJPEG select the RTSP icon If the IP camera uses H 264 select the RTSP H...

Page 99: ...h a search of the camera model number and the word rtsp 3 3 34 Hik test tool Hik test tool app is design for activating and debugging Hikvision camera can auto identify unactivated hikvision camera al...

Page 100: ...password tap ok to activate 3 Confirm activation After activating the camera the program default modifies the camera IP Activated multiple cameras in the local area Network and pop up menu to modify...

Page 101: ...lay image from the camera Modify network information Change the camera IP address subnet mask and gateway etc Modify user information Modify the camera s user name and password Factory Reset Camera fa...

Page 102: ...camera it can display image and modify IP user name and password etc Making Dahua camera test more convenient and quickly Click DH icon to enter Dahua test tool Select the camera of the online detect...

Page 103: ...f the camera not supports non verification login please select camera of online detection menu and input correct user name and password then click log in After logging successful you can test it Play...

Page 104: ...ion modify camera parameter such as ip address subnet mask gateway etc Modify user information modify camera user name and password which is onvif Dahua test tool IPC TESTE user name and password not...

Page 105: ...y reset 3 3 36 Update Copy the downloaded update file to SD card update directory if no directory please create one Click the icon to open the Update menu Select Local Update to update via the SD card...

Page 106: ...e interface click related applications update to the latest version 3 3 37 Office Quick office app support excel word ppt format doc editable 3 3 38 LED Flashlight It is convenient for the installatio...

Page 107: ...icon to enter Type in the camera s IP address and press Go to access the IP camera s interface NOTE You will not be able to view live video in the web browser For viewing video use the IP tester s liv...

Page 108: ...ing results click the key Save to save the contents Notepad can auto record the storage date and time pls click to view the notepad all saving contents display Click each record bar to show the detail...

Page 109: ...n to enter Language Select your desired language English Chinese Korean Russian Italian Polish Spanish French or Japanese Typewriting You can select typewriting or install other typewriting Date Time...

Page 110: ...NS address or select Dynamic allocation to use DHCP WLAN Net Turn WiFi off or on by pressing the Open the wifi button Once WiFi is turned on and click connected WIFI it will scan for wireless networks...

Page 111: ...e desired brightness of the IP tester and adjust the sleep time settings Volume Set volume level SD Card Displays SD Card Capacity You can also format the SD card or unmounts it before removing it FTP...

Page 112: ...ntering the PTZ controller app This needs to be turned on in order to use the PTZ Scan feature of the PTZ app Online Registration Online update need register first after the tester connect to network...

Page 113: ...tern Restore the factory settings If the tester to restore factory settings all your personal files and apps will be removed 3 3 42 File explorer Click File on the top bar tool can select internal or...

Page 114: ...109 FTP server You can choose internal or external SD card Other operation details please refer to FTP settings...

Page 115: ...y color icon several seconds the selected color icon will be auto move the rectangle area if you press selected color several seconds and it will be auto deleted Theme colors include fixed order and r...

Page 116: ...s application background Set color as application background Set at the same time Setting color as desktop background and application background Cancel Cancel current setting Picture Click Picture to...

Page 117: ...d right folding rotate effect Ombre effect etc selecting one of effect to view slide effect in the square area and click set to save 3 4 Audio test You can test the audio input from audio pickup devic...

Page 118: ...s straight line cable and has no short circuit otherwise will damage the tester b Before using PoE power output pls check the IP camera whether supports POE powered Otherwise it will damage the IP cam...

Page 119: ...no power outlet for the adapter to power the camera the tester can offer temporary power for it But we do not suggest tester supply power for a long time Notice a Don t input any power into the DC12...

Page 120: ...ter has a sufficient charge otherwise the tester will not able to provide enough output power 3 8 USB 5V 2A power output When the tester is turned on the 12VDC and 5VDC power output functions are auto...

Page 121: ...video signal test Optional 1 channel SDI input BNC interface resolution support 720p 25 30 50 60 1080p 25 30 50 60 1080i 50 60 CVI video signal test Optional 1 channel CVI input BNC interface resoluti...

Page 122: ...el audio signal input and 1 channel audio signal output to connect headphones PTZ control Support RS232 RS485 control Baud 600 115200bps Compatible with more than 30 protocols such as PELCO D P Samsun...

Page 123: ...eter Operation setting OSD menu select your desired language English Chinese Korean Russian Italian French Polish Spanish Japanese etc Auto off 1 30 mins General Working Temperature 10 50 Working Humi...

Page 124: ...mV 660 0V 100mV DC current Range Accuracy Resolution 6 600mA 0 5 3 1uA 66 00mA 10uA 660 0mA 100uA 10 00A 1 5 10mA AC current Range Accuracy Resolution 6 600mA 0 5 3 1uA 66 00mA 10uA 660 0mA 100uA 10 0...

Page 125: ...0 3 the tester will sound Diode Range Resolution Function 2 0V 1mV Schottky diode 0 15 0 25V rectifier diode 0 6 1 0V triode PN junction 0 5 0 8V Capacitance Range Accuracy Resolution 6 600nF 0 5 20 1...

Page 126: ...0 Connector type FC PC 4 4 Visual fault locator specifications Laser type LD Wavelength Calibration 650nm Output power 5mW Optional 10mW 20mW Modulation mode CW 1Hz 2Hz Measurement Range 5KM Optional...