background image

EN

User Guide

LAN TESTER

Summary of Contents for I-CT PRO-LAN

Page 1: ...EN User Guide LAN TESTER ...

Page 2: ...nstruction Put the Device always on a stable and straight Surface In case of falling it can be damaged Don t place the Device into direct Sunlight or in Places with high Temperature This can damage the Device or shorten his average useful Life Don t place it in the near of Heat Sources like Radiators or other heat producing Devices Don t expose the Device to Rain Water Wetness or high Humidity Don...

Page 3: ...rdable so you can benefit the most 2 1 Specification x Test the correct pin configuration of 10Base T 10Base 2 Ethernet cable RJ45 RJ11 modular cables 258A TIA 568A 568B and Token Ring Cable etc x Easy to read cable status and verify cable continuity open short and miswire x With remote kit it can remotely test cable far away either on wall plate or patch panel x Test the grounding x With auto or ...

Page 4: ...LAY FOR SOURCING END JACK l 4 LED DISPLAY FOR RECEIVING END JACK 2 5 POWER SWITCH 6 LED SCANNING MODE SWITCH 7 TEST SWITCH FOR MANUAL SCAN 8 RJ45 JACK 9 LED DISPLAY FOR RECEIVING END SAME AS JACK 2 10 GROUND LED FOR RECEIVING END 11 BATTERY COMPARTMENT 9V 10 8 1 2 3 4 5 6 7 9 11 ...

Page 5: ...e the battery power is sufficient If battery fails to the power the LEDs will be dimmed or hold up or no light and the test result will be incorrect 3 Choose the Auto Manual switch to be Auto scan mode or Manual scan mode by pressing the Auto Manual switch 4 In this moment the corresponding LED indicators of another row of LED will light up simutaneousIy 5 Read out the result of LED display It tel...

Page 6: ...both RJ45 jacks then connect the tested cable both ends on BNC adaptor cables 2 As to the remaining procedures you may refer to 10Base T cable test from step 1 2 to 1 5 Note 1 The center pin of BNC should be read on LED 1 and shielding pin of BNC should be read on LED 2 BNC CENTER PIN BNC SHIELDING 2 As the 10Base 2 cable has only two wires we suggest you to read the result of LED scan by manual m...

Page 7: ... has already installed on the patch panel or wall plate you may use the adaptor cable to solve the connector gender problem Patch Panel Wall Plate 2 Now set the Auto manual switch on Auto mode if you work test alone 3 Read the test result from LED display on remote unit Note The LED display on remote unit was scanned in sequence corresponding to the sourcing end of master unit 6 ...

Page 8: ......