background image

48-Port Gigabit Ethernet PoE+  Managed Switch with Four 10G SFP+ Uplinks

 

User Manual

 

 

 

56

 

 

6.2.5

 

EAPS Protocol 

Selecting 

Advanced Application

>

EAPS Protocol

 in the navigation bar lets you configure EAPS 

protocol.

 

 

6.2.5.1

 

Ethernet Automatic Protection Switching 

Selecting 

Advanced Application

>

EAPS Protocol

>

Ethernet automatic protection switching

 in the 

navigation bar lets you configure Ethernet automatic protection switching.

 

 

 

 

Summary of Contents for 561587

Page 1: ...48 Port Gigabit Ethernet PoE Layer2 Managed Switch with Four 10G SFP Uplinks User Manual Model 561587 intellinetnetwork com ...

Page 2: ...and maintaining switch hardware It supposes that user knows the related terms and concept of Ethernet Document structure Chapter One Product Introduction introduces hardware technical index and related modules Chapter Two Preparation for Instalation makes a list of requirements of safety power environment etc Chapter Three Installing the Switch introduces the installation of the Switch and modules...

Page 3: ...idity Requirements 11 2 2 3 Cleanliness Requirements 11 2 2 4 EMI 12 2 2 5 System Grounding Requirements 12 2 2 6 Safety Grounding 12 2 2 7 Lightning Grounding 13 2 2 8 EMC grounding 13 2 2 9 Surge Protector Considerations 13 2 2 10 EMI Consideration 13 2 3 NOTES ON FIBER OPTIC CONNECTIONS 14 2 4 INSTALLATION TOOLS 14 3 INSTALLING THE SWITCH 15 3 1 INSTALLATION OVERVIEW 15 3 1 1 Confirmations Pre ...

Page 4: ...ic Routing 31 6 1 4 Port Setup 32 6 1 5 DHCP Server 34 6 1 5 1 DHCP server pool set 34 6 1 5 2 DHCP server group set 35 6 1 6 DHCP Relay 36 6 1 7 Stacking 36 6 1 7 1 Stacking Status 36 6 1 7 2 Stacking Configuration 37 6 2 ADVANCED APPLICATION 39 6 2 1 VLAN 39 6 2 1 1 VLAN Status 41 6 2 1 2 VLAN Port Settings 42 6 2 1 3 Static VLAN 44 6 2 2 MAC Address Forwarding 46 6 2 3 Spanning Tree Protocol 47...

Page 5: ...6 2 18 1 Multicast Status 81 6 2 18 2 Multicast Settings 82 6 2 18 3 IGMP Snooping Deny VLAN 83 6 2 18 4 IGMP Filtering Profile 84 6 2 19 IPv6 Multicast 85 6 2 19 1 IPv6 Multicast Status 85 6 2 19 2 IPv6 Multicast Setting 86 6 2 19 3 MLD Snooping Deny VLAN 88 6 2 20 DoS Attack Protect 89 6 2 21 DHCP Snooping Setting 92 6 2 21 1 DHCP Snooping Setting 93 6 2 21 2 IP Source Guard 94 6 2 22 SNTP Setti...

Page 6: ...c 112 6 3 4 Syslog 113 6 3 4 1 Syslog Setup 114 6 3 4 2 Syslog Server Setup 115 7 APPENDIX CONNECTORS AND CONNECTION MEDIA 117 7 1 1000BASE T 100BASE TX 10BASE T PORTS 117 7 2 OPTICAL FIBER CONNECTION 118 8 ADDITIONAL INFORMATION 119 8 1 WASTE ELECTRICAL ELECTRONIC EQUIPMENT 119 8 2 WARRANTY 120 8 3 REGULATORY STATEMENTS 120 ...

Page 7: ...mum 100 m 100Base Tx UTP category 5 5e cable maximum 100 m 1000Base T UTP category 5e 6 cable maximum 100 m 1000Base X MMF SMF 10GBase X MMF SMF Interface 48 x 10 100 1000 Mbps ports 4 x 10G SFP ports 1x Console port Transfer Method Store and Forward Switching Capacity 16 K MAC Address Learning 136 Gbps Packet Forwarding Rate 101 184 Mpps Packet Buffer 1 5 MBytes Jumbo Frame 12 KBytes Indicators P...

Page 8: ...signed to connect with the serial port of a computer or terminal for monitoring and configuring the Switch 4 Reset button Reset Keep the device powered on and push a paper clip into the hole Press down the button for 6 seconds to restore the Switch to its original factory default settings 5 LED indicator The LED Indicators will allow you to monitor diagnose and troubleshoot any potential problem w...

Page 9: ...s connected to the port at a speed of 10 100 Mbps Flashing Sending or receiving data at a speed of 10 100 Mbps Green Off No link established On A device is connected to the port at a speed of 1000 Mbps Flashing Sending or receiving data at a speed of 1000 Mbps 1G SFP port indicators 49S 52S Orange Off No link established On A device is connected to the port at a speed of 1 Gbps Flashing Sending or...

Page 10: ...all power modules 2 1 3 Electrical Safety Observe local regulations and specifications when performing electric operations Relevant operators must be qualified Before installing the device carefully check any potential danger in your surroundings such as an ungrounded power supply and damp wet ground or floor Before installing the device find out the location of the emergency power supply switch i...

Page 11: ...t will be damaged In an environment with high relative humidity the insulating material may have bad insulation or have poor power efficiency The switch materials may suffer degradation in mechanical performance and metallic parts may get rusted In an environment with low relative humidity however the insulating strip may dry and shrink Static electricity may occur easily and endanger the circuit ...

Page 12: ...uld be adopted to effectively filter out interference from the power grid through the filtering circuit The switch should be located at places free from the transmission of large power radio waves radar and high frequency large current devices If necessary electromagnetic shielding should be adopted Use proper cabling Avoid damages to device signal interfaces caused by over voltage or over current...

Page 13: ...s supply cable A surge protector for this switch is not included but should be purchased by users as required For how to use the surge protector refer to its related manual 2 2 10EMI Consideration Electro Magnetic Interference EMI from either outside or inside the equipment or application system affects the system in the conductive ways such as capacitive coupling inductive coupling and electromag...

Page 14: ...rent device Measures must be taken to shield static electricity 2 3 Notes on fiber optic connections In an optical fiber connection pay attention to connector types and fiber types and make sure they are compatible Make sure the sending equipment is connected with receiving equipment and vice versa 2 4 Installation tools The tool kit is customer supplied Common tools Phillips screwdriver Straight ...

Page 15: ...User Manual 15 3 Installing the Switch Ensure that you have carefully read the section of Preparation before Installation Make sure that the requirements set forth in that section have been met 3 1 Installation Overview Only professional technicians should install the equipment ...

Page 16: ... grounding terminal Make sure that the power cable is in good contact after connection Do not place heavy objects on the switch Ensure adequate ventilation 10 cm or more to the switch to ensure good heat dissipation Do not stack The switch location is far away from a strong power radio transmitter radio transmitting station high frequency high current equipment if necessary adopt an electromagneti...

Page 17: ... the air around the switch is well ventilated 3 3 Power Cord Connection Ensure that the ground wire is connected before connecting the power cord Connect the AC power cord Follow these steps to complete the connection a Connect one end of the switch to the power socket on the back panel of the switch cabinet b Plug the other end of the power cord into an external AC power outlet to power the switc...

Page 18: ... to a component due to connection errors Check that the ground line is connected Check that the cables and power input cables are correctly connected Check that the 100 meter cables are laid out inside the equipment room In the case of external cabling check that the lightning resistance socket or network interface lightning protector is connected Check that sufficient ventilation space is availab...

Page 19: ...48 Port Gigabit Ethernet PoE Layer2 Managed Switch with Four 10G SFP Uplinks User Manual 19 4 Common Troubleshooting for Installation 4 1 General Installation Troubleshooting Overview ...

Page 20: ...wisted pair cable is faulty The length of the cable exceeds 100 m 330 ft The port has special configuration that has no common working mode with the connected switch Replace the twisted pair cable Check that the port configuration has the common working mode with the connected switch The fiber port cannot be connected The Rx and Tx ends are connected reversely The interconnected optical module typ...

Page 21: ...ally adjust to the characteristics MDI MDI X speed duplex of the device to which is connected Sample connection Figure 5 1 Connect PC to Switch 5 2 Switch connections to Powered Devices This PoE Switch can supply power to compatible devices Each port offers a maximum output up to 30 W to power an internet phone network camera wireless access point or other device Use appropriate cable to directly ...

Page 22: ...he Switch 3 Check whether the IP address of the computer is within this network segment 192 168 1 xxx xxx ranges 2 254 for example 192 168 1 100 4 Open the browser and enter http 192 168 2 1 Then press Enter The Switch login window appears as shown below 5 Switch the language to English Enter the Username and Password The factory default Username is admin and Password is the serial number found on...

Page 23: ...tatus bar at the top the menu bar on the left and the main configuration window in the middle of the screen Select the different functions in the menu bar to modify settings in the main configuration window 6 1 Basic Setting Choose Basic Setting and the following page appears There are System Info General Setup IP Setup Port Setup Dhcp server DHCP Relay and Stacking configuration web pages ...

Page 24: ...the basic information of System and configure the IP address and System name PARAMETER DESCRIPTION INSTRUCTIONS View and configure Running System status CONFIGURATION EXAMPLE Setting IP address as 192 168 2 1 and System name as Switch Configuring IP address as 192 168 2 1 6 1 1 1 Vlan Interface Parameter Description IP Address The management IP of the Switch System name System name ...

Page 25: ...select the way of interface including vlan interface and supervlan interface Vlan ID Choose the Vlan ID 6 1 1 2 Vlan Interface Config Set IP address as 192 168 2 1 and mask as 255 255 255 0 and then selecting override Override You can override or not override the original main IP address 6 1 1 3 Static Routing ...

Page 26: ...ay IP Address setting IP Address Setting System name as Switch 6 1 2 General Setup Selecting Basic Setting General Setup in the navigation bar lets you view the basic information of Switch Such as System description and so on You can also modify System name System contact and System location PARAMETER DESCRIPTION Parameter Description System name System name System contact Including company or rel...

Page 27: ...r Manual 27 CONFIGURATION EXAMPLE Setting System name as Switch 6 1 3 IP Setup Selecting Basic Setting IP Setup in the navigation bar lets you configure IP 6 1 3 1 Vlan Interface Selecting Basic Setting IP Setup Vlan Interface in the navigation bar lets you configure Vlan interface ...

Page 28: ...IPTION 6 1 3 2 Vlan Interface Config Selecting Basic Setting IP Setup Vlan interface Config in the navigation bar lets you configure Vlan Interface Config Parameter Description Interface Selecting the interface vlan interface Supervlan interface Vlan ID You can specify the vlan ID Name The name of interface ...

Page 29: ...ETER DESCRIPTION CONFIGURATION EXAMPLE Setting IP address as 192 168 2 1 6 1 3 3 Vlan Interface Parameter Description Interface name Name of interface Vlan ID You can specify the vlan ID IP Address User login in Switch using the IP Address Override You can override formeroriginal primary IP or not ...

Page 30: ...ort Gigabit Ethernet PoE Layer2 Managed Switch with Four 10G SFP Uplinks User Manual 30 6 1 3 4 Vlan Interface Config Setting IP address as 192 168 2 1 and mask as 255 255 255 0 and then selecting override ...

Page 31: ...Routing Selecting Basic Setting IP Setup Static Routing in the navigation bar lets you specify some routing manually PARAMETER DESCRIPTION Parameter Description Destination IP Address Setting destination IP Address of Static Routing IP Subnet Mask Setting IP Subnet Mask Gateway IP Address Setting IP Address ...

Page 32: ...Gigabit Ethernet PoE Layer2 Managed Switch with Four 10G SFP Uplinks User Manual 32 6 1 4 Port Setup Selecting Basic Setting Port Setup in the navigation bar lets you configure the related parameters of a port ...

Page 33: ... Parameter Description Port Port number status Choose whether to close link port link Status Down up priority Set port priority the range of 0 7 Set speed Choose the following modes auto half 100 full 100 half 1000 full 1000 Port 25 28 can choose the following modes 10 Gigabit fiber equipment has this function module Full 1000 Full 10000 Mode Choose the following kinds auto slave master Actual spe...

Page 34: ... 34 6 1 5 DHCP Server Selecting Basic Setting DHCP Server in the navigation bar lets you configure a DHCP server pool and DHCP server group 6 1 5 1 DHCP server pool set Selecting Basic Setting DHCP server DHCP server pool set in the navigation bar lets you configure a DHCP Server pool set ...

Page 35: ...P server group set in the navigation bar lets you configure DHCP Server group PARAMETER DESCRIPTION Parameter Description ip pool ip pool ID name Set the name of ip pool hire time Set hire time Gate Address Set Gate Address Ip Mask Set Ip Mask First DNS Set First DNS Secondary DNS Set Secondary DNS Parameter Description group id DHCP server group id IP address DHCP server IP address ...

Page 36: ...dden DHCP Server Set the source IP used 6 1 7 Stacking Selecting Basic Setting Stacking in the navigation bar lets you view the stack interface information neighbor interface information start the stack function and set system priority 6 1 7 1 Stacking Status Selecting Basic Setting Stacking Stacking Status in the navigation bar lets you view the stack interface information and neighbor interface ...

Page 37: ...rameter Description Slot Each device in the system must manually specify an unrepeatable ID number unique identity Status Two different working modes Single machine mode this mode is the same as the general switch does not to provide stack function Stack mode this mode opens the stack function can make up a stack system with other devices Priority Each device in the system can be assigned a priori...

Page 38: ...t for changes to take effect CONFIGURATION EXAMPLE 1 Activate the Stacking Configuration and configure System Priority as 3 2 Click the Freeze button to restore the Slot ID Parameter Description Active Select open or close stack System Priority Set system priority the default is 0 Slot id Freeze Freeze slot ID Slot id After Reboot Device number after the device is rebooted ...

Page 39: ...SI layer 3 constructs VLANs can be used to partition a local network into several distinctive segments VLAN technology provides the following advantages 1 Broadcast traffic does not cross into different VLANs which reduces bandwidth utilization and improves network performance 2 Security in your LAN can be improved since packets in different VLANs cannot communicate with each other directly 3 With...

Page 40: ...o not add a VLAN tag to any incoming untagged packet d Trunk ports are ideal for switch to switch connections or for devices that have the ability to tag packets by themselves such as VoIP phones 3 Hybrid Ports a These are a combination of access and trunk ports b Hybrid ports will tag any incoming packet that has no VLAN ID with the VLAN ID the port has been assigned to c Hybrid ports will also a...

Page 41: ...N Status Selecting Advanced Application VLAN VLAN Status in the navigation bar lets you view VLAN status PARAMETER DESCRIPTION CONFIGURATION EXAMPLE View the VLAN of VID as 1 Parameter Description VLAN Status View all VLANs configured in the device VLAN Search by VID Enter VID to view the specified VLAN ...

Page 42: ...igabit Ethernet PoE Layer2 Managed Switch with Four 10G SFP Uplinks User Manual 42 6 2 1 2 VLAN Port Settings Selecting Advanced Application VLAN VLAN Port Settings in the navigation bar lets you set VLAN ports ...

Page 43: ...llowing modes Hybrid The port can be either a tag member or untag member in a VLAN and can be a member port for multiple VLANs Trunk The port can only be a tag member in a VLAN and can be a member port for multiple VLANs Access The port can only be a member of untag in VLAN and the port can only be in a VLAN Port GVRP Select open or close GVRP dynamic VLAN learning function port mode must be Trunk...

Page 44: ... with Four 10G SFP Uplinks User Manual 44 6 2 1 3 Static VLAN Selecting Advanced Application Static VLAN in the navigation bar lets you configure a Static VLAN PARAMETER DESCRIPTION Parameter Description VLAN Group ID VLAN Group ID Name VLAN Group name ...

Page 45: ...SFP Uplinks User Manual 45 CONFIGURATION EXAMPLE Add and delete VLAN members Adding a new VLAN VLAN Group ID 120 contains untag member ports 6 and 8 and tag member ports 18 and 20 The user can modify the port member by clicking on the white area below the port number ...

Page 46: ...on bar lets you configure MAC Address Forwarding PARAMETER DESCRIPTION INSTRUCTIONS Blackhole MAC If a PC s MAC address is configured on a switch to be a blackhole MAC then the PC s package will be discarded by the switch and not forwarded to the network CONFIGURATION EXAMPLE 1 MAC Address Forwarding Parameter Description MAC Type MAC Type Static MAC Dynamic MAC Blackhole MAC Permanent MAC ...

Page 47: ...aged Switch with Four 10G SFP Uplinks User Manual 47 2 Unknown source mac packet drop settings 6 2 3 Spanning Tree Protocol Selecting Advanced Application Spanning Tree Protocol in the navigation bar lets you configure spanning tree protocol ...

Page 48: ... the navigation bar lets you view spanning tree protocol status PARAMETER DESCRIPTION Parameter Description Root Path Cost Configure Root Path Cost Hello time second Switches sends bpdu in packet interval Max age second Ports that have not yet received a message in the time will initiate topology changes Forwarding delay second The state of the port switch time Topology changed times The number of...

Page 49: ...anning Tree configuration in the navigation bar lets you configure spanning tree PARAMETER DESCRIPTION CONFIGURATION EXAMPLE Spanning Tree Mode as Rapid Spanning Tree open Global Spanning Parameter Description Spanning Tree Mode Spanning tree mode IEEE Compatible Spanning Tree Rapid Spanning Tree Multiple Spanning Tree Global Spanning Tree Status Select open or close Global Spanning ...

Page 50: ...Four 10G SFP Uplinks User Manual 50 6 2 3 3 Compatible Rapid Spanning Tree Protocol Selecting Advanced Application Spanning Tree Protocol Compatible Rapid Spanning Tree Protocol in the navigation bar lets you configure Compatible Rapid Spanning Tree Protocol ...

Page 51: ...s 15 seconds 2 The priority of port 24 is 64 and the path cost is 20000 Parameter Description Bridge Priority Set bridge priority the default instance bridge priority for 32768 Hello Time Switches sends bpdu in packet interval Max Age Ports that have not yet received a message in the time will initiate topology changes Forwarding Delay The state of the port switch time Port Priority Set port insta...

Page 52: ...Switch with Four 10G SFP Uplinks User Manual 52 6 2 3 4 Multiple Spanning Tree Protocol Selecting Advanced Application Spanning Tree Protocol Multiple Spanning Tree Protocol in the navigation bar lets you configure Multiple Spanning Tree Protocol ...

Page 53: ... initiate topology changes Forwarding Delay The state of the port switch time Maximum Hops Set the maximum number of hops that BPDUs can support in the spanning tree Configuration Name Fill in configuration name Revision Number Set revision number Instance Instance number Bridge Priority Priority setting bridge example the default instance bridge priority for 32768 VLAN Range Set VLAN range Port P...

Page 54: ...ged Switch with Four 10G SFP Uplinks User Manual 54 2 Instance 3 The priority of port 24 is 64 and the path cost is 20000 6 2 4 ERPS Protocol Selecting Advanced Application ERPS Protocol in the navigation bar lets you configure ERPS protocol ...

Page 55: ... close ERPS Instance The range of 0 15 active instance Meg level The range of 0 7 Ring Id The range of 1 239 Ring Level Master Ring and Sub Ring Control VLAN You must configure the VLAN before configuring the ERRP ring Protected instance List Application of MST instance Ring port1 Configurable ports are common owner neighbor next neighbor Ring port2 Configurable ports are common owner neighbor nex...

Page 56: ...Selecting Advanced Application EAPS Protocol in the navigation bar lets you configure EAPS protocol 6 2 5 1 Ethernet Automatic Protection Switching Selecting Advanced Application EAPS Protocol Ethernet automatic protection switching in the navigation bar lets you configure Ethernet automatic protection switching ...

Page 57: ...nfigure the information timeout Major Fault The Major Fault timer will be automatically updated by the system Pre Forward The Pre forward timer will be automatically updated by the system Pre Up Loop recovery wait time Domain ID You need to specify the Domain ID when creating the EAPS Domain Control VLAN You must configure the VLAN before configuring the EAPS Ring Work mode Work mode standard huaw...

Page 58: ...t Ethernet PoE Layer2 Managed Switch with Four 10G SFP Uplinks User Manual 58 2 Domain 6 2 5 2 EAPS Domain Selecting Advanced Application EAPS Protocol EAPS Domain in the navigation bar lets you configure EAPS Domain ...

Page 59: ... Domain ID Select Domain ID Control VLAN You must configure the VLAN before configuring the EAPS Ring Work mode Work mode standard huawei eips subring Topo Collect Select open or close Topo Collect Active Select open or close Ring Ring ID Select ring ID Query Solicit Select open or close Query Solicit Bridge Role Bridge Role master transit edge assistant edge Level Level 0 1 ...

Page 60: ... Ethernet PoE Layer2 Managed Switch with Four 10G SFP Uplinks User Manual 60 2 Configure Ring 6 2 6 VRRP Protocol Selecting Advanced Application VRRP Protocol in the navigation bar lets you configure the VRRP Protocol ...

Page 61: ... EAPS Protocol Layer 2 Tunneling Protocol in the navigation bar lets you configure the specified protocol message that enters the port to perform a tunnel operation Parameter Description VRRP ID list You select VRRP ID VRRP ID VRRP ID Interface name Specify VLAN virtual ip Set virtual IP preempt Enable or disable preempt priority VRRP priority interval Set VRRP timer interval ...

Page 62: ...Gigabit Ethernet PoE Layer2 Managed Switch with Four 10G SFP Uplinks User Manual 62 CONFIGURATION EXAMPLE 6 2 8 PPPoE IA Selecting Advanced Application PPPoE IA in the navigation bar lets you configure PPPoE IA ...

Page 63: ...ation PPPoE IA Intermediate Agent in the navigation bar lets you configure an Intermediate Agent PARAMETER DESCRIPTION CONFIGURATION EXAMPLE Configure Intermediate Agent Parameter Description delimiter Configure delimiter choose space format Configure format choose binary ascii type Configure the message type choose standard Huawei self defined ...

Page 64: ...n bar lets you configure ports PARAMETER DESCRIPTION CONFIGURATION EXAMPLE Configure port Parameter Description active Select open or close port PPPoEIA Server Trusted State Configure the upstream port to be Trusted or Untrusted Drop Configure the pppoe padi pado packets received by the port Strategy Configuration options to handle policies choose Drop Keep Replace ...

Page 65: ...trol Selecting Advanced Application Bandwidth Control in the navigation bar lets you configure Bandwidth Control INSTRUCTIONS 1 Mbit s 1000 Kbit s 1000 8 KB s 125 KB s That is the theoretical rate of 1M bandwidth is 125 KB s CONFIGURATION EXAMPLE Configure port 24 Ingress Rate is 64 kbps Egress Rate is 128 kbps ...

Page 66: ...hat is the theoretical rate of 1M bandwidth is 125 KB s CONFIGURATION EXAMPLE Set Port 1 broadcast as 6400 pps multicast as 3200 pps unicast as 3200 pps Parameter Description Broadcast Broadcast rate limitation the range of 64 32000000 unit pps you must enter multiple of 64 default to 49984 Multicast Multicast rate limitation the range of 64 32000000 unit pps you must enter multiple of 64 default ...

Page 67: ...ng PARAMETER DESCRIPTION Parameter Description Active Select open or close Mirroring Monitor Port Set up the monitoring port and forward the flow data of the source port to the message analyzer to analyze the message and then forward to the monitoring port Mirrored Check the box to configure the mirror source port Direction Configure the direction of the mirror message choose Ingress Egress Both ...

Page 68: ... Manual 68 CONFIGURATION EXAMPLE Open mirroring configure monitoring port is port 8 the source port is port 7 and the mirror message is in both directions 6 2 12Link Aggregation Selecting Advanced Application Link Aggregation in the navigation bar lets you configure link aggregation ...

Page 69: ...Uplinks User Manual 69 6 2 12 1Link Aggregation status Selecting Advanced Application Link Aggregation Link Aggregation Status in the navigation bar lets you view link aggregation status You can view Group ID Enabled Ports Synchronized Ports Aggregator ID Criteria Status ...

Page 70: ... Aggregation Link Aggregation Setting in the navigation bar lets you set Link Aggregation PARAMETER DESCRIPTION Parameter Description Group ID Add the port to the specified Aggregation Group ID LACP mode Configure port aggregation static active passive Criteria Configure the Aggregation Group load balancing src mac dst mac src dst mac src ip dst ip src dst ip ...

Page 71: ...n Group port 8 6 2 12 3Link Aggregation Control Protocol Selecting Advanced Application Link Aggregation Link Aggregation Control Protocol in the navigation bar lets you configure Link Aggregation Control Protocol PARAMETER DESCRIPTION Parameter Description System priority Aggregation group system priority the default is 32768 the range of 1 65535 ...

Page 72: ...10G SFP Uplinks User Manual 72 CONFIGURATION EXAMPLE 1 Open aggregation group T1 LACP 2 The priority for configuring port 8 is 64 6 2 13Port Security Selecting Advanced Application Port Security in the navigation bar lets you configure port address learn control ...

Page 73: ... control set Max Mac Limit Number to 1800 4 Configure Address Learn Channel Control set max MAC limit number channel to 1500 Parameter Description Age Enable Open age enable Age Time Set Age Time the range of 10 1000000 unit second Max Mac Limit Number Global Set the global Max MAC Limit Number 0 16384 Address Learning The MAC address learning function of port enables the power switch the default ...

Page 74: ... Vlan Control set Max Mac Limit Number Vlan to 1900 6 2 14PoE Settings Selecting Advanced Application PoE Settings in the navigation bar lets you configure PoE Only PoE devices have this function 6 2 14 1PoE Settings Selecting Advanced Application PoE Settings PoE Settings in the navigation bar lets you configure PoE ...

Page 75: ...48 Port Gigabit Ethernet PoE Layer2 Managed Switch with Four 10G SFP Uplinks User Manual 75 PARAMETER DESCRIPTION Parameter Description Power limit 1 400 The power of switch PoE can be limited ...

Page 76: ...limit to 390 W 6 2 14 2PoE Port Settings Selecting Advanced Application PoE Settings PoE Port Settings in the navigation bar lets you configure PoE ports PARAMETER DESCRIPTION Parameter Description Enable Turn the port PoE power on and off default is open Standard Configure IEEE802 3af IEEE802 3at mode default to IEEE802 3at ...

Page 77: ...anced Application Classifier in the navigation bar lets you configure Classifier PARAMETER DESCRIPTION Priority Configure port Priority low critical high the default priority is low Power limit The power of switch PoE can be limited Parameter Description Active Active Classifier Layer2 Set VLAN Priority Ethernet type Source Mac Address DSCP IP Protocol Layer3 Set Source IP ...

Page 78: ...48 Port Gigabit Ethernet PoE Layer2 Managed Switch with Four 10G SFP Uplinks User Manual 78 CONFIGURATION EXAMPLE ...

Page 79: ...16Policy Rule Selecting Advanced Application Policy Rule in the navigation bar lets you configure Policy Rules PARAMETER DESCRIPTION Parameter Description Active Active Policy Rule Classifier s You need to match the set of classification rules Parameter Set Bandwidth Egress Port Priority DSCP TOS ...

Page 80: ...G SFP Uplinks User Manual 80 6 2 17Queuing Method Selecting Advanced Application Queuing Method in the navigation bar lets you configure a queuing method PARAMETER DESCRIPTION CONFIGURATION EXAMPLE Parameter Description Method Five methods SPQ WRR SP WRR WFQ SP WFQ ...

Page 81: ...ed Application Multicast in the navigation bar lets you configure Multicast 6 2 18 1Multicast Status Selecting Advanced Application Multicast Multicast Status in the navigation bar lets you view all multicast settings This includes the static configuration and the multicast that is learned through the IGMP Snooping protocol ...

Page 82: ...hernet PoE Layer2 Managed Switch with Four 10G SFP Uplinks User Manual 82 6 2 18 2Multicast Settings Selecting Advanced Application Multicast Multicast Settings in the navigation bar lets you configure multicast settings ...

Page 83: ...Timeout Configure the dynamic group sowing time default is 300s IGMP Route Port Forward Open IGMP Route Port Forward Max Group Limit Max learning group of configuration port default is 1020 Fast Leave Open port quick exit function i e when the port receives the IGMP and leaves the message immediately remove the port from the reshuffle group Multicast Vlan The configuration group multicast the defa...

Page 84: ...SFP Uplinks User Manual 84 PARAMETER DESCRIPTION Vid VLAN s ID 6 2 18 4IGMP Filtering Profile Selecting Advanced Application Multicast IGMP Filtering Profile in the navigation bar lets you add and remove the preview feature of the modified group Parameter Description ...

Page 85: ...he navigation bar lets you configure IPv6 Multicast 6 2 19 1IPv6 Multicast Status Selecting Advanced Application IPv6 Multicast IPv6 Multicast Status in the navigation bar lets you view all IPv6 Multicast groups Parameter Description Profile ID The range of 1 128 Profile Limit Profile rules can be permit or deny Input Format The preview address can be configured to be either IP or MAC ...

Page 86: ...t PoE Layer2 Managed Switch with Four 10G SFP Uplinks User Manual 86 6 2 19 2IPv6 Multicast Setting Selecting Advanced Application IPv6 Multicast IPv6 Multicast Setting in the navigation bar lets you configure IPv6 Multicast ...

Page 87: ...querier Host Timeout Configure Dynamic IPv6 multicast aging time default is 300s MLD Route Port Forward Enable or disable MLD Route Port Forward Max Group Limit Configure maximum learning IPv6 Multicast message of port default is 1020 Fast Leave Enable or disable Fast Leave i e when the port receives an IGMP leave message the port is deleted immediately from the IPv6 multicast group IPv6 Multicast...

Page 88: ... Four 10G SFP Uplinks User Manual 88 6 2 19 3MLD Snooping Deny VLAN Selecting Advanced Application IPv6 Multicast MLD Snooping Deny VLAN in the navigation bar lets you configure MLD Snooping Deny VLAN PARAMETER DESCRIPTION Parameter Description Vid VLAN ID ...

Page 89: ...bit Ethernet PoE Layer2 Managed Switch with Four 10G SFP Uplinks User Manual 89 6 2 20DoS Attack Protect Selecting Advanced Application DoS attack protect in the navigation bar lets you configure DoS Attack Protect ...

Page 90: ... DESCRIPTION CONFIGURATION EXAMPLE 1 cpu queue control Parameter Description cpu queue control The CPU queue is controlled by setting minimum bandwidth and maximum bandwidth minimum value is 64 kbps dos attack control The DOS attack is controlled by the discarding behavior of the corresponding message ...

Page 91: ...48 Port Gigabit Ethernet PoE Layer2 Managed Switch with Four 10G SFP Uplinks User Manual 91 2 DoS attack control ...

Page 92: ...it Ethernet PoE Layer2 Managed Switch with Four 10G SFP Uplinks User Manual 92 6 2 21DHCP Snooping Setting Selecting Advanced Application DHCP Snooping Setting in the navigation bar lets you configure DHCP Snooping ...

Page 93: ...nced Application DHCP Snooping Setting DHCP Snooping Setting in the navigation bar lets you configure DHCP Snooping Settings PARAMETER DESCRIPTION CONFIGURATION EXAMPLE Parameter Description DHCP Snooping Enable Enable or disable DHCP Snooping Trust Enable or disable the DHCP Snooping port trust property state Maxclients Set Maxclients ...

Page 94: ... Source Guard Selecting Advanced Application DHCP Snooping Setting IP Source Guard in the navigation bar lets you configure IP Source Guard PARAMETER DESCRIPTION CONFIGURATION EXAMPLE Parameter Description Disable unbinding entry to access network Enable or disable unbinding entry to access the network ...

Page 95: ...48 Port Gigabit Ethernet PoE Layer2 Managed Switch with Four 10G SFP Uplinks User Manual 95 6 2 22SNTP Setting Selecting Advanced Application SNTP Setting in the navigation bar lets you configure SNTP ...

Page 96: ... SNTP Client SNTP Client Mode SNTP Client Mode broadcast anycast multicast unicast SNTP Client Poll Interval The interval the SNTP Client sends requests to SNTP Server SNTP Client Retransmit Times If SNTP Client does not receive a response within a certain period of time after sending a request it will resend the request until the number of retransmissions exceeds the set value SNTP Client Retrans...

Page 97: ... Port Gigabit Ethernet PoE Layer2 Managed Switch with Four 10G SFP Uplinks User Manual 97 CONFIGURATION EXAMPLE 6 2 23QinQ Selecting Advanced Application QinQ in the navigation bar lets you configure QinQ ...

Page 98: ...User Manual 98 6 2 23 1Set Up QinQ Selecting Advanced Application QinQ Set up QinQ in the navigation bar lets you Set up QinQ PARAMETER DESCRIPTION Parameter Description Active Enable or disable global QinQ QinQ Enable or disable QinQ of ports Port Mode Port Mode uplink customer ...

Page 99: ...ernet PoE Layer2 Managed Switch with Four 10G SFP Uplinks User Manual 99 CONFIGURATION EXAMPLE 6 2 23 2Flexible QinQ Selecting Advanced Application QinQ Flexible QinQ in the navigation bar lets you configure Flexible QinQ ...

Page 100: ...8 Port Gigabit Ethernet PoE Layer2 Managed Switch with Four 10G SFP Uplinks User Manual 100 CONFIGURATION EXAMPLE 6 2 24AAA Selecting Advanced Application AAA in the navigation bar lets you configure AAA ...

Page 101: ...48 Port Gigabit Ethernet PoE Layer2 Managed Switch with Four 10G SFP Uplinks User Manual 101 6 2 24 1802 1x Selecting Advanced Application AAA 802 1x in the navigation bar lets you configure 802 1x ...

Page 102: ...re than the allowed value he or she will not be allowed to try to log in for a certain time Active Active disable portbased multi portbased single macbased Port Control Port Control auto forceauthorized forceunauthorized Reauthentication After user authentication is passed the port can be configured to reauthenticate or periodically re authenticate Reauthentication Timer Time range of Reauthentica...

Page 103: ...e and password when the client is authenticated The username information generally includes the ISP information of user domain and the ISP of one to one correspondence the main information domain is the domain of the user is authenticated and accounted by which RADIUS server Parameter Description Active Enable or disable radius domain Domain Name Set domain name Radius Server Name Set Radius Serve...

Page 104: ...pplication AAA Remote Authentication in the navigation bar lets you configure Remote Authentication PARAMETER DESCRIPTION 6 2 24 4TACACS Server Setup Selecting Advanced Application AAA TACACS Server Setup in the navigation bar lets you configure TACACS Server Setup Parameter Description Authenication Mode Authenication Mode Local Radius Tacacs ...

Page 105: ...ETER DESCRIPTION 6 2 24 5Radius Server Setup Selecting Advanced Application AAA Radius Server Setup in the navigation bar lets you configure Radius Server Setup Parameter Description Authenication Type Authenication Mode ascii Chap pap Preemption Time The time range of Preemption Time 0 1440 minutes ...

Page 106: ...nce in the navigation bar lets you upgrade firmware restart the system and perform maintenance on the switch Parameter Description 8021P Priority After this function is turned on if the user authentication is pass it will modify the PVID of the user s port H3C Cams In this feature you can configure the version information of transmitting clients to the RADIUS server through the RADIUS attribute cl...

Page 107: ...e firmware go to the Firmware Upgrade menu and select the file on your computer using the Host File Path button Then click Open to begin the upload 2 Restart system Restart type Restart Restart with Factory Defaults 3 OAM Diag Virtual cable can be tested 6 3 2 Access Control Selecting Management Access Control in the navigation bar lets you set SNMP and Logins ...

Page 108: ...TER DESCRIPTION Parameter Description Community Name Community string equal to the NMS and Snmp agent communication between the password Access privilege Read only specify the NMS Snmp host of MIB variables can only be read cannot be modified Read write specify the NMS Snmp host of MIB variables can only read can also be modified Version Set version v1 v2c v3 IP Set the IP address of the trap host...

Page 109: ...Add a group name public community access to Read Write Set host 192 168 1 100 to receive trap messages The specified version is v2c 6 3 2 2 User Information Selecting Management Access Control User Information in the navigation bar lets you add user set their Security Level Authentication Privacy Group and Password ...

Page 110: ...plinks User Manual 110 PARAMETER DESCRIPTION CONFIGURATION EXAMPLE Add group initial add username user1 Parameter Description Username Snmp username Security Level noauth auth pri Authentication MD5 SHA Privacy DES Privacy Group User group name Password Encrypted password ...

Page 111: ...nks User Manual 111 6 3 2 3 Logins Selecting Management Access Control Logins in the navigation bar lets you modify the admin password and configure ordinary users PARAMETER DESCRIPTION CONFIGURATION EXAMPLE Parameter Description User privilege 0 1 Normal 2 15 administrator ...

Page 112: ...8 Port Gigabit Ethernet PoE Layer2 Managed Switch with Four 10G SFP Uplinks User Manual 112 6 3 3 Diagnostic Selecting Management Diagnostic in the navigation bar lets you Display or Clear the System Log ...

Page 113: ...bit Ethernet PoE Layer2 Managed Switch with Four 10G SFP Uplinks User Manual 113 CONFIGURATION EXAMPLE Display System Log 6 3 4 Syslog Selecting Management Syslog in the navigation bar lets you configure the syslog ...

Page 114: ...anagement Syslog Syslog Setup in the navigation bar lets you start the logging function globally and the logging function of the corresponding module PARAMETER DESCRIPTION Parameter Description Facility local use 0 7 kernel userlevel mail system sercurity_1 2 sysogd lineprinter Networknews uucp clock_1 2 ftp logaudit logalert ...

Page 115: ...ernet PoE Layer2 Managed Switch with Four 10G SFP Uplinks User Manual 115 CONFIGURATION EXAMPLE 6 3 4 2 Syslog Server Setup Selecting Management Syslog Syslog Server Setup in the navigation bar lets you set syslog server ...

Page 116: ...UCTIONS Open the log switch set up the syslog server and the system log will be automatically pushed to the server CONFIGURATION EXAMPLE 1 set server address is 192 168 1 100 Parameter Description Server Address Syslog Server Address Log Level Level 0 Level 0 1 Level 0 2 Level 0 3 Level 0 4 Level 0 5 Level 0 6 Level 0 7 ...

Page 117: ...r transmission all of which must be connected Figure A 1 shows the connections of the twisted pairs used by the 1000BASE T port Four Twisted Pairs of the 1000BASE T Figure A 1 In addition to the above cables the 100BASE TX 10BASE T can also use 100 ohm Category 3 4 5 cables for 10 Mbps and 100 ohm Category 5 cables for 100 Mbps both of which can be up to 100 m Figure A 2 shows the pinouts of the 1...

Page 118: ...wisted pair and cross twisted pair connection Figure A 3 7 2 Optical Fiber Connection For the optical fiber ports select single mode or multiple mode optical fibers for connection according to the fiber module connected The connection schematic diagram is shown in Figure A 4 Figure A 4 Optical Fiber Connections Straight Through Crossover Crossover ...

Page 119: ...nicos RAEE este producto eléctrico no puede desecharse se con el resto de residuos no clasificados Deshágase de este producto devolviéndolo a su punto de venta o a un punto de recolección municipal para su reciclaje FRANÇAIS Ce symbole sur Ie produit ou son emballage signifie que ce produit ne doit pas être traité comme un déchet ménager Conformément à la Directive 2012 19 EU sur les déchets d équ...

Page 120: ...resentar el producto al distribuidor en el domicilio donde fue adquirido o en el domicilio de IC Intracom México S A P I de C V junto con los accesorios contenidos en su empaque acompañado de su póliza debidamente llenada y sellada por la casa vendedora indispensable el sello y fecha de compra donde lo adquirió o bien la factura o ticket de compra original donde se mencione claramente el modelo nú...

Page 121: ...ispositivo cumple con los requerimientos de CE 2014 30 EU y o 2014 35 EU La declaración de conformidad esta disponible en FRANÇAIS Cet appareil satisfait aux exigences de CE 2014 30 EU et ou 2014 35 EU La Déclaration de Conformité est disponible à POLSKI Urządzenie spełnia wymagania CE 2014 30 EU I lub 2014 35 EU Deklaracja zgodności dostępna jest na stronie internetowej producenta ITALIANO Questo...