1.2.
Specifications
Dimensions (Inches)
16.5 H x 4.5 W x 2 D
Dimensions (Millimeters)
420 H x 115 W x 45 D
Mounting Options
Externally mount with loose CT’s
Meter Current Inputs
1 to 45
Voltage Rating
Auto range 120-347VAC (L-N), -20% to +10% of rating
Rated VA
< 12 VA
Current Range
CTs Primary 0 – 600A, CTs Secondary 0 – 0.1A
Meter Constant (K
h
)
1Wh, 1VAh or 10Wh, 10VAh or 100Wh, 100VAh
Service type:
1Φ2W, 1Φ3W, 2Φ3W, 3Φ4W, 3Φ3W (Delta*)
Current Transformers
Secondary Max 80/100mA CTs, Self-Shorting Protection
Instrument Transformers Interface
Yes
Measurements
•Total Energy: kWh, kVAh are accumulated in non-volatile memory on
the meter
•Real Time Measurements: V, I, kW, kVA, kVar, pf, Hz, Per phase V & I
Total Harmonic Distortion (THD), Per phase V & I individual harmonic
order up to 23rd
Communication
ModBus RTU or TCP/IP, BACnet MSTP or TCP/IP and pulse output.
Frequency
45 to 65 Hz
Accuracy Class
0.5 (Meets ANSI C12.20)
Total Energy
kWh, kVAh are accumulated in non-volatile memory on the meter
Real Time Measurements
V, I, kW, kVA, kVar, pf, Hz, Per phase V & I Total Harmonic Distortion
(THD), Per phase V & I individual harmonic order up to 23
rd
Operating Temperature
-10°C to +53°C
Regulatory Compliance / Approvals
Measurement Canada,
C
CSA
US
,
C
UL
US
, CTEP (CA)
Patent
U.S. Patent No. 8,049,488