CH 1 Offset
With this option selected, push-turn the encoder to set a display offset for the CH 1 waveform.
Waveforms can be offset ± 10V (-10000µV - +10000µV).
Offsetting waveforms is particularly
useful if you want to display CH 1’s
waveform above (or below) CH 2’s
waveform. For example, assume CH 1
and CH 2 are both typical ± 5V
waveforms. If you set both the CH 1
and CH 2 Display Values to 5.0 V per
division, then each waveform is ½ the
entire height of the scope. If you set
the
CH 1 Offset
to +5000 (+5V) and
the
CH 2 Offset
(described below) to
-5000 (-5V), then CH 1’s waveform is displayed in the top half of the scope, and CH 2’s is displayed
in the bottom half.
CH 2 Offset
With this option selected, push-turn the encoder to set a display offset for the CH 2 waveform.
Waveforms can be offset
± 10V (-10000µV - +10000µV).
Grid Display
With this option selected, push-turn the encoder to select between two options:
grd: on
turns on the scope’s background grid
grd: --
turns off the scope’s background grid
Zeroscope 1U Manual
12