DT-TPC

User Manual

telephone converter

Please read this manual carefully before using the product you purchase, and 
keep it well for future use.We reserve the right to modify the specification in 
this manual at any time without notice.

Summary of Contents for DT-TPC

Page 1: ...al telephone converter Please read this manual carefully before using the product you purchase and keep it well for future use We reserve the right to modify the specification in this manual at any time without notice ...

Page 2: ... so on Maximum 3 telephone number can be set on monitor Must be with TPC function for monitor Divert Calls from monitor to telephone via TPC the TPC is like a telephone when setting the diversion function door station calls TPC first then divert to the telephone number you set Application villa and apartment 150mm 140 mm 60 mm About TPC Unit 1 Terminal Introduction 1 ON DIP 2 3 4 5 6 DIP ON 1 2 3 ...

Page 3: ... set on monitor are invalid K1 LED3 will light up when press down the button and the Debug mode is activated LED3 will turn off when press down the button again and return to Normal mode K2 LED3 will flash when press down the button and the Test mode is activated LED3 will turn off when press down the button again and return to Normal mode SW501 Refer to 3 2 JW501 485 connection port used to updat...

Page 4: ...st the volume of outdoor station the volume is twice louder than normal the volume is normal Bit3 adjust the configuration of audio match the telephone network to DT system not match Bit4 adjust the configuration of audio match PBX system to DT system not match 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 ON Note 1 Bit1 and bit2 can not be on state at the sa...

Page 5: ...partment Bit state Discription TPC just is a monitor that its user code is 15 besides the monitors with its user code from 00 to 14 can be read and written but you should know that the divert mode will be adopted from the monitor with its user code 00 TPC just is a monitor that its user code is 31 besides the monitors with its user code from 16 to 30 can be read and written but you should know tha...

Page 6: ...2 3 4 5 6 ON Code 25 1 2 3 4 5 6 ON Code 4 1 2 3 4 5 6 ON Code 15 1 2 3 4 5 6 ON Code 26 1 2 3 4 5 6 ON Code 5 1 2 3 4 5 6 ON Code 16 1 2 3 4 5 6 ON Code 27 1 2 3 4 5 6 ON Code 6 1 2 3 4 5 6 ON Code 17 1 2 3 4 5 6 ON Code 28 1 2 3 4 5 6 ON Code 7 1 2 3 4 5 6 ON Code 18 1 2 3 4 5 6 ON Code 29 1 2 3 4 5 6 ON Code 8 1 2 3 4 5 6 ON Code 19 1 2 3 4 5 6 ON Code 30 1 2 3 4 5 6 ON Code 9 1 2 3 4 5 6 ON Co...

Page 7: ...e diverted to your telephone immediately At this mode the monitor won t shut off when TPC deverts sucessfully but if the monitor answers the call at this time TPC will quit absolutely Exit Save Exit Unsave Telephone Number 1 _ 2 _ 3 _ Don t divert calls Divert if not answered Divert simultaneously 1 2 3 4 5 6 9 8 7 0 TPC configure 1 0 2 3 4 Divert mode select 2 0 Not 1 Not Answer 2 Simulateously C...

Page 8: ...t 2 telephone numbers must be set on monitor 2 During communication between telephone and outdoor station button has not been input on telephone and the calling time of each group number is less than 80 seconds Calling slave telephone Add a letter P between master telephone and slave telephone The TPC will call the slave telephone directly Priority calling The J102 terminal will be shut off before...

Page 9: ...PC Code 0 DIP 6 off 1 2 3 4 5 6 ON Code 13 DIP 6 off 1 2 3 4 5 6 ON Code 14 DIP 6 off 1 2 3 4 5 6 ON Bit1 off DIP 6 off 1 3 2 4 5 6 ON ID 00 1 2 ON IN OUT CALL UNLOCK TALK MON IN USE CALL UNLOCK TALK MON IN USE CALL UNLOCK TALK MON IN USE Note The TPC unit occupies a user code of 15 8 ...

Page 10: ...4 5 6 ON 1 2 3 4 5 6 ON 1 2 3 4 5 6 ON HI Code 14 DIP 6 on Code 12 DIP 6 on Code 13 DIP 6 on Code 11 DIP 6 on CALL UNLOCK TALK MON IN USE CALL UNLOCK TALK MON IN USE CALL UNLOCK TALK MON IN USE CALL UNLOCK TALK MON IN USE DBC 4 A B C D IN OUT 1 2 3 4 5 6 ON Code 1 DIP 6 on 1 2 3 4 5 6 ON Code 2 DIP 6 on 1 2 3 4 5 6 ON Code 3 DIP 6 on DBC 4 A B C D IN OUT 85 260AC DPS PS5 ID 00 1 2 ON TPC Note The ...

Page 11: ...e network 1 2 3 4 5 6 ON 1 2 3 4 5 6 ON 1 2 3 4 5 6 ON 1 2 3 4 5 6 ON 1 2 3 4 5 6 ON 1 2 3 4 5 6 ON 85 260AC DPS PS5 CALL UNLOCK TALK MON IN USE CALL UNLOCK TALK MON IN USE CALL UNLOCK TALK MON IN USE TPC IN IN OUT OUT TPC TPC IN OUT Basic in out mode for apartment Note If slave monitors are connected in one user the TPC unit occupies the adress of the third slave monitor 10 ...

Page 12: ... 6 ON 1 2 3 4 5 6 ON Code 30 DIP 6 on 1 2 3 4 5 6 ON Code 30 DIP 6 on Code 29 DIP 6 on 1 2 3 4 5 6 ON Code 29 DIP 6 on 1 2 3 4 5 6 ON 1 2 3 4 5 6 ON Code 32 DIP 6 on 1 2 3 4 5 6 ON Code 32 DIP 6 on Code 31 DIP 6 on 1 2 3 4 5 6 ON Code 31 DIP 6 on DBC 4 A B C D IN OUT 85 260AC DPS PS5 ID 00 1 2 3 4 5 6 ON TPC IN OUT TPC IN OUT TPC IN OUT TPC IN OUT TPC IN OUT TPC IN OUT TPC IN OUT TPC IN OUT HI DBC...