LSU220A : Load Support Unit
Operators Manual
6 SPECIFICATIONS
INPUTS:
Mains Supply
Three phase star connected
L1 – N
210-240VAC 3.30KW Max.
L2 – N
210-240VAC 1.65KW Max.
L3 – N
210-240VAC 1.65KW Max.
50-60Hz
OUTPUTS:
Voltage
10.0V Minimum
27.0V Maximum
Current
220A @ 27.0V Maximum
OVERLOAD PROTECTION:
105-125% of output power.
Constant power to 75% of set output voltage
then output shuts down, recycle AC to reset
SHORT CIRCUIT PROTECTION:
Output latches off, recycle AC to reset.
METER ACCURACY:
Voltage accuracy
±0.2V
Current Accuracy
±2.0A
ENVIRONMENTAL:
Temp Operating
0°C ~ 40°C
Temp Storage
-10°C ~ 60°C
Humidity
20% - 90% Non condensing
Altitude
0 to 3000 Metres.
IP Rating:
Operating
IP33
Doc: DWG1063-08-R2 LSU220A Operators Manual.odt
Page 14 of 16
Copyright Material of Intelligent Charging Limited © 2018
Printed On : 17/07/19