USB or RS-232 Controlled
!aaMdddddddd – Set Temporary Memory State
Description
This command defines the temporary memory state until power is shot down
Syntax
!aaMdddddddd <CR>
!
Delimiter character
aa
Hexadecimal address of the device
M
System control command
d
Relay output activation command data for each nibble in hex format
<CR> Carriage Return - End of command
Response
|Mdddddddd<CR> if the command was valid
Example
Command: !00M80000000<CR>
Response: |M80000000<CR>
This command will set relay #32 in memory only
This command does not function while “Relays pair” operation is selected.
In this case command ‘!aa3dd’ and ‘!aa4dd’ should be used instead.
See
for more information about Single/Pair operation.
In Order to start this command, user must start
“Activate Relays per Memory Status” (Command
Note
!