12000 Series Switches
•
Off
: module is in the removable state.
2.10.3.2
Module Attention
The Attention LED indicates one of the following conditions:
•
Off
: the system functioning normally.
•
Steady Amber
: the system requires some attention, which could indicate one of
the following conditions:
— The switch temperature is at a warning level on the module.
— The switch silicon temperature is at a warning level (approximately 90 degrees
C).
— DC voltages on the board are slightly out of tolerance (12V Bulk, 5V, 3.3V and
1.8V are all monitored).
— The module can no longer function properly. The system will take the
appropriate actions to ensure that no damage is done to its components.
•
Blinking Amber
(once every four seconds): LED test state.
2.10.4
SEEB Module
2.10.4.1
RJ45 LEDs
The RJ45 connectors have two LEDs,
Act
and
100
. The
100
LED is
Green
when a
100Mbps link is connected. The
Act
LED is
Amber
when an Ethernet link has been
established, and blinking when the link is active.
Figure 60.