Server System SR1695GPRX Service Guide
5
NOTES:
1. Blink rate is ~1 Hz at 50% duty cycle.
2. It is also off when the system is powered off (S5) or in a sleep state (S1).
3. The power LED sleep indication is maintained on standby by the chipset. If the system is
powered down without going through the BIOS, the LED state in effect at the time of power off
is restored when the system is powered on until the BIOS clear it.
4. If the system is not powered down normally, it is possible the Power LED will blink at the same
time the system status LED is off due to a failure or configuration change that prevents the
BIOS from running.
Table 4. SSI Power LED Operation
Table 3. Front LED Indicator Functions
LED
Color
State
Description
Power/Sleep
Green
On
Power on/ACPI S0 state.
Green
Blink
Sleep/ACPI S1 state.
-
Off
Power Off/ACPI S5 state.
LAN
Green
On
LAN Link no Access.
Green
Blink
LAN Activity.
-
Off
No link.
System Status
Green
On
System Ready/No Alarm.
Green
Blink
System ready, but degraded: redundancy lost such as the
power supply or fan failure; non-critical temp/voltage
threshold; battery failure; or predictive power supply failure.
Amber
On
Critical Alarm: Critical power modules failure, critical fans
failure, voltage (power supply), critical temperature and
voltage.
Amber
Blink
Non-Critical Alarm: Redundant fan failure, redundant power
module failure, non-critical temperature and voltage.
Off
Off
Power off: System unplugged.
Power on: System powered off and in standby, no prior
degraded\non-critical\critical state.
State
Power Mode
LED
Description
Power off
Non-ACPI
Off
System power is off and the BIOS has not initialized the
chipset.
Power on
Non-ACPI
Solid on
System power is on but the BIOS has not yet initialized the
chipset.
S1 Sleep
ACPI
Blink
DC power is still on. The operating system has saved
context and gone into a level of low-power state.
Summary of Contents for SR1695GPRX
Page 4: ...iv Intel Server System SR1695GPRX Service Guide...
Page 6: ...vi Intel Server System SR1695GPRX Service Guide...
Page 16: ...xviii Intel Server System SR1695GPRX Service Guide...
Page 20: ...xxii Intel Server System SR1695GPRX Service Guide...
Page 33: ...Intel Server System SR1695GPRX Service Guide 13 Server Board Connectors Components...
Page 38: ...18 Intel Server System SR1695GPRX Service Guide...
Page 102: ...82 Intel Server System SR1695GPRX Service Guide...
Page 136: ...116 Intel Server System SR1695GPRX Service Guide Intel Intel Intel Web UL...
Page 137: ...Intel Server System SR1695GPRX Service Guide 117 ITE ITE 5V...
Page 138: ...118 Intel Server System SR1695GPRX Service Guide...
Page 139: ...Intel Server System SR1695GPRX Service Guide 119 ESD ESD ESD ESD ESD...
Page 140: ...120 Intel Server System SR1695GPRX Service Guide...
Page 154: ...134 Intel Server System SR1695GPRX Service Guide...
Page 158: ...138 Intel Server System SR1695GPRX Service Guide...
Page 162: ...142 Intel Server System SR1695GPRX Service Guide...