Summary of Contents for S5000PSL

Page 1: ...Intel Server Board S5000PSL User Guide A Guide for Technically Qualified Assemblers of Intel Identified Subassemblies Products Intel Order Number D36217 003...

Page 2: ...changes to specifications and product descriptions at any time without notice Intel server boards contain a number of high density VLSI and power delivery components that need adequate airflow for co...

Page 3: ...nt Toolkit 2 0 CD oder unter http support intel com support motherboards server sb cs 010770 htm Consignes de s curit Lisez attention toutes les consignes de s curit et les mises en garde indiqu es da...

Page 4: ...iv Intel Server Board S5000PSL http support intel com support motherboards server sb CS 010770 htm Intel Server Boards and Server Chassis Safety Information Intel...

Page 5: ...result Electrostatic discharge ESD and ESD protection ESD can damage disk drives boards and other parts We recommend that you perform all procedures in this chapter only at an ESD workstation If one...

Page 6: ...vi Intel Server Board S5000PSL...

Page 7: ...place components on the Intel Server Board S5000PSL For the latest version of this manual see http support intel com support motherboards server S5000PSL Manual Organization Chapter 1 provides a brief...

Page 8: ...eed more information about this product or information about the accessories that can be used with this server board use the following resources These files are available at http support intel com sup...

Page 9: ...ction on the web page titled Compatibility To make sure your system falls within the allowed power budget Power Budget Analysis Tool See the section on the web page titled Installation Use Software to...

Page 10: ...x Intel Server Board S5000PSL...

Page 11: ...onfiguration Jumpers 7 Intel Light Guided Diagnostics 9 Back Panel Features 12 RAID Support 13 SATA Server Board 13 SAS Server Board 14 ROMB Server Board 15 Hardware Requirements 16 Processor 16 Memor...

Page 12: ...ce Information 49 Product Regulatory Compliance 49 Product Safety Compliance 49 Certifications Registrations Declarations 50 Product Regulatory Compliance Markings 50 Electromagnetic Compatibility Not...

Page 13: ...Cannot Connect to a Server 61 Problems with Network 61 System Boots when Installing PCI Card 62 Problems with Newly Installed Application Software 62 Problems with Application Software that Ran Correc...

Page 14: ...xiv Intel Server Board S5000PSL...

Page 15: ...27 Figure 9 Locating DIMM Sockets 30 Figure 10 Installing FBDIMMs 31 Figure 11 Locating Processor Sockets 34 Figure 12 Opening Processor Socket Lever 35 Figure 13 Opening Load Plate 35 Figure 14 Remov...

Page 16: ...xvi Intel Server Board S5000PSL...

Page 17: ...oard Features 2 Table 3 NIC LEDs 12 Table 4 Setup Menu Key Use 22 Table 5 Heatsink Requirements for Compatible Intel Server Chassis 37 Table 6 Product Certification Markings 50 Table 7 Resetting the S...

Page 18: ...xviii Intel Server Board S5000PSL...

Page 19: ...n features of the Intel Server Board S5000PSL This chapter provides a photograph of the product a list of the server board features and diagrams showing the location of important components and connec...

Page 20: ...000X Chipset Intel 6321ESB I O Controller Hub Intel 5000X Memory Controller Hub Cooling Support for Two processor fans 4 pin headers Four front fans 6 pin headers Two rear fans 4 pin header 3 pin fans...

Page 21: ...NIC connectors for 10 100 1000 Mb connections Dual GbE with Intel I O Acceleration Technology Intel I O AT through the Intel 8256EB Network Connection Four USB 2 0 ports at the back of the board Inte...

Page 22: ...PCI Express slot add in card slot 4 Product code S5000PSLSAS Intel Embedded Server RAID Technology II provides SAS SATA RAID 0 1 and 10 with optional RAID 5 support provided by the Intel RAID Activat...

Page 23: ...sockets see Figure 5 on page 17 GG Enclosure management SAS SGPIO header product code S5000PSLSAS only B PCI X 64 bit 100 133 MHz slot 2 R Processor 1 socket HH Enclosure management SAS SES2 product...

Page 24: ...y on product code S5000PSLSAS J RMM connector connector for Intel Remote Management Module Z System fan 1 header PP USB port K Back panel I O ports see Figure 4 on page 12 AA Processor power connector...

Page 25: ...umpered for 5 to 10 seconds the CMOS settings will be cleared on the next server reset These pins should not be jumpered for normal operation Note The server does not need to be reset with the jumpers...

Page 26: ...red for normal operation Note The server does not need to be reset with the jumpers on these pins for the password to be cleared To use this jumper to reset the password Power down the server Place th...

Page 27: ...gnostic LEDs to help you identify failed and failing components and to help you identify the server from among several servers Except for the ID LED the status LED and the 5 volt standby LED the LEDs...

Page 28: ...s LED The status LED indicates whether a system is operating correctly has experienced a minor fault or a major system error For details about this LED see the Technical Product Specification F ID LED...

Page 29: ...andby LED This LED is green whenever AC power is applied to the system The system does not need to be powered on in order for this LED to be on R Processor 2 fault LED This LED indicates a fault has o...

Page 30: ...ottom F Bit 1 LED POST LED B Status LED G LSB LED POST LED C ID LED H Serial A top Video bottom D MSB LED POST LED I NIC1 top two USB bottom E Bit 2 LED POST LED J NIC 2 top two USB bottom Table 3 NIC...

Page 31: ...anced modes affect the RAID configuration as follows Legacy supports four disk drives and does not provide RAID support Enhanced supports six disk drives and is required for RAID configurations When t...

Page 32: ...ded Server RAID Technology II is available This enables SAS RAID modes 0 1 or 10 for the four blue ports on the server board These SAS controller can mix SAS and SATA drives If the SAS option ROM is d...

Page 33: ...e Intel RAID Smart Battery can be installed to provide up to 65 hours of data cache protection during a power outage Intel Integrated Server RAID supports up to 16 physical drives and up to 64 logical...

Page 34: ...ist of supported processors see the links under Additional Information and Software Memory The Intel Server Board S5000PSL provides eight DIMM sockets in two branches Each branch contains two channels...

Page 35: ...ckets Callout DIMM Socket Callout DIMM Socket A Branch 1 Channel A DIMM_A1 E Branch 2 Channel C DIMM_C1 B Branch 1 Channel A DIMM_A2 F Branch 2 Channel C DIMM_C2 C Branch 1 Channel B DIMM_B1 G Branch...

Page 36: ...terms of timing technology or size If the FBDIMMs on adjacent channels of a branch are not identical the FBDIMM on the higher channel is disabled If Branch 0 cannot support the dual channel mode of op...

Page 37: ...RAID Smart Battery Product Code S5000PSLROMB only The Intel RAID Smart Battery product code AXXRSBBU3 is a small battery pack accessory The Smart Battery preserves the contents of the RAID Cache DIMM...

Page 38: ...time Keyboard video and mouse control KVM is redirected to a managing system This provides remote control USB media redirection allows you to use a USB device anywhere on the network as if it was ins...

Page 39: ...er after POST completes the memory test When you have moved the CMOS jumper on the server board to the Clear CMOS position enabled In the two conditions listed above during the Power On Self Test POST...

Page 40: ...or the F5 function key is used to change the value of the current item to the previous value This key scrolls through the values in the associated pick list without displaying the full list F6 or Chan...

Page 41: ...as performed This provides a safeguard against problems that might happen during the upgrade such as a power outage during the upgrade process This is called the rolling BIOS feature F9 Setup Defaults...

Page 42: ...the procedure Obtaining the Upgrade Download the BIOS image file to a temporary folder on your hard drive See Additional Information and Software for a link to the update software Note Review the inst...

Page 43: ...wn the server and disconnect the AC power 2 Open the chassis See your chassis documentation for instructions on removing the chassis cover 3 Locate the BIOS Bank Select jumper at board position J1C3 S...

Page 44: ...chassis See your chassis documentation for instructions on removing the chassis cover 3 Locate the Passwrd Clr jumper block at board position J1D2 See Figure 7 4 Move the jumper from the normal opera...

Page 45: ...ctions on removing the chassis cover 3 Locate the CMOS Clr jumper block at board position J1D1 See Figure 8 4 Move the jumper from the normal operation position covering pins 1 and 2 to the CMOS Clear...

Page 46: ...28 Intel Server Board S5000PSL...

Page 47: ...M_D1 and DIMM_D2 starting from the inside of the board DIMM_A1 is the socket closest to the MCH See Memory on page 16 for a discussion of the memory requirements and options See Additional Information...

Page 48: ...ecessary to access the DIMM sockets See the documentation that came with your chassis for instructions on removing chassis components Figure 9 Locating DIMM Sockets Callout DIMM Socket Callout DIMM So...

Page 49: ...edge of the FBDIMM into the socket 11 When the FBDIMM is inserted push down on the top edge of the FBDIMM until the retaining clips snap into place See letter C in Figure 10 12 Make sure the clips lat...

Page 50: ...ackage 8 Reinstall and reconnect any parts you removed or disconnected to reach the DIMM sockets See the documentation that came with your chassis for instructions on installing chassis components 9 R...

Page 51: ...drop into place To install a processor follow these instructions 1 Observe the safety and ESD precautions in Safety Information on page iii 2 Turn off all peripheral devices connected to the server T...

Page 52: ...entation that came with your chassis for instructions on removing chassis components 7 Push down on the lever attached to the processor socket While holding the lever down pull it towards the center o...

Page 53: ...35 Figure 12 Opening Processor Socket Lever 8 Push down on the rear tab of the load plate to swing the front of the load plate up slightly Fully open the load plate See Figure 13 Figure 13 Opening Lo...

Page 54: ...over 11 Set the processor in the socket with the processor cutouts matching the processor socket notches See Figure 15 Figure 15 Setting Processor in Place 12 Close the load plate 13 Close the socket...

Page 55: ...to be connected to the server board The following table shows the Intel server chassis compatible with this server board and whether each chassis requires an active or a passive heatsink Table 5 Heat...

Page 56: ...ith the four posts surrounding the processor 3 Loosely screw in the captive screws on the heat sink corners in the order shown by Figure 16 Do not fully tighten one screw before loosely attaching the...

Page 57: ...or disconnected to reach the processor sockets See the documentation that came with your chassis for instructions on installing chassis components 7 Replace the chassis cover and reconnect the AC pow...

Page 58: ...s 6 Active heatsink only Unplug the processor fan cable from the server board 7 Loosen the four captive screws on the corners of the heat sink 8 Twist the heat sink slightly to break the seal between...

Page 59: ...towards the center of the board to disengage the lever from the hook Fully open the lever See Figure 18 Figure 18 Opening Processor Socket Lever 11 Push down on the rear tab of the load plate to swing...

Page 60: ...her the processor or the processor socket Figure 20 Removing Processor from Socket 13 Store the processor in the packaging materials in which it came 14 Install the protective cover over the load plat...

Page 61: ...it loses voltage and the system settings stored in CMOS RAM in the RTC for example the date and time may be wrong Contact your customer service representative or dealer for a list of approved devices...

Page 62: ...g and Removing the CMOS Battery 7 Dispose of the battery according to local ordinance 8 Remove the new battery from its package 9 Being careful to observe the correct polarity insert the battery into...

Page 63: ...e without notice Before calling fill out an System Issue Report Form A sample form is provided on the following pages However for the fastest service please submit your form via the Internet For an up...

Page 64: ...via Philippines New Zealand 0800 444 365 Pakistan 632 63684 15 IDD via Philippines Philippines 1 800 1 651 0117 Singapore 65 6213 1311 Taiwan 2 2545 1640 Thailand 1 800 631 0003 Vietnam 632 6368416 I...

Page 65: ...ictel Contact AT T USA at 1 800 225 528 Once connected dial 800 843 4481 Guatemala Contact AT T USA at 99 99 190 Once connected dial 800 843 4481 Mexico Contact AT T USA at 001 800 462 628 4240 Once c...

Page 66: ...48 Intel Server Board S5000PSL...

Page 67: ...uired to comply with Class A emission requirements because it is intended for a commercial type market place Intel targets 10db margin to Class A Limits The Intel Server Board S5000PSL has been has be...

Page 68: ...MED Declaration of Conformity New Zealand BSMI Certification Taiwan Belarus Listed on one System License Belarus RRL Certification Korea Ecology Declaration International Product Regulatory Compliance...

Page 69: ...ll not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is enc...

Page 70: ...emissions from digital apparatus set out in the interference causing equipment standard entitled Digital Apparatus ICES 003 of the Canadian Department of Communications Europe CE Declaration of Confor...

Page 71: ...me On License and Product 2 Certification No On RRL certificate Obtain certificate from local Intel representative 3 Name of Certification Recipient Intel Corporation 4 Date of Manufacturer Refer to d...

Page 72: ...d pending RoHS exemption applies RoHS implementation details are not fully defined and may change Threshold limits and banned substances are noted below Quantity limit of 0 1 by mass 1000 PPM for Lead...

Page 73: ...n see Getting Help on page 45 for assistance System Boot Quiet Time The power on self test POST process includes a quiet time during which the system may appear to be hung This may last as long as 40...

Page 74: ...ll jumper and switch settings on add in boards and peripheral devices correct To check these settings refer to the manufacturer s documentation that comes with them If applicable ensure that there are...

Page 75: ...monitor 4 If the operating system normally loads from the hard disk drive make sure there is no diskette in drive A and no CD ROM disk in the CD ROM drive 5 If the power LED does light attempt to boo...

Page 76: ...might be loose Have you securely plugged the server AC power cord into the power supply Some power supplies have a power switch on the back of the power supply next to the fan If your system has one i...

Page 77: ...mply with the system requirements Make sure the memory FBDIMMs have been populated according to the system requirements Remove the memory FBDIMMs and re seat them Make sure the processor s comply with...

Page 78: ...control panel LEDs lit Have any of the fan motors stopped Use the server management subsystem to check the fan status Have your fans speeded up in response to an overheating situation Have your fans...

Page 79: ...roblems with Network The system hangs when the drivers are loaded Certain drivers may require interrupts that are not shared with other PCI drivers For these drivers it may be necessary to alter setti...

Page 80: ...urn off the server power by using the power button on the front of the system Unplug the AC power cord s from the server Problems with Newly Installed Application Software Problems that occur when you...

Page 81: ...nd the system not responding to user commands Note Random errors in data files If you are getting random errors in your data files they may be getting corrupted by voltage spikes on your power line If...

Page 82: ...ntel Light Guided Diagnostics on page 9 BIOS POST Beep Codes The table below lists the POST error beep codes Prior to system video initialization the BIOS uses these beep codes to inform users of erro...

Page 83: ...ction to Take 1 Front panel CMOS clear has been initiated 1 5 1 1 Processor failure Reseat or replace the failed processor 1 5 2 1 No processor is installed or the CPU 1 socket is empty Reseat or repl...

Page 84: ...66 Intel Server Board S5000PSL...

Page 85: ...st page for space to include a detailed problem description ____________________________________________________________________ ____________________________________________________________________ __...

Page 86: ...________ DIMM D1 MB and vendor part number __________________________________ DIMM D2 MB and vendor part number __________________________________ Operating System Information Operating System _______...

Page 87: ..._______________________________________ Control Panel Information Standard Control Panel _________________________________________________ Intel Local Control Panel____________________________________...

Page 88: ..._________________________________________________________________ ____________________________________________________________________ _________________________________________________________________...

Reviews: