Intel® Server Board S3420GP TPS
Server Management Capability for Intel® Server Board S3420GPV
Revision 2.4
Intel order number E65697-010
41
Main
Advance
d
Security
Server Management
Boot
Options
Boot
Manager
Hardware monitor
Real-time Temperature and Voltage Status
Fan Controller
Auto
/Manual
CPU Fan Altitude
300m
/900m/
1500m/3000m
Board Fan Altitude
300m
/900m/
1500m/3000m
Figure 15. Setup Utility — Hardware Monitor Screen Display
Table 13. Setup Utility — Hardware Monitor Screen Fields
Setup Item
Options
Help Text
Voltage and
Temperature Status
display monitored voltage, current
Fan speed PWM and temperature
CPU Fan Controller
Auto
Manual
CPU temperature control policy
Auto -
Fan speed control setting by
default
Manual -
user adjust Fan speed
control setting value manually
CPU Fan Altitude
300m/900m/1500m/3000m
Select CPU FAN default
PWM
according to altitude under Auto
mode
Board Fan Altitude
300m/900m/1500m/3000m
Select Board Fan default PWM
according to altitude under Auto
mode
Hysteresis
2
Degree
Celsius
3 Degree Celsius
4 Degree Celsius
Hysteresis – is used to smoothing
the FAN speed transition when
temperature approaching
temperature target upward or
downward. Select Hysteresis to keep
FAN at the same speed within the
range
Default Fan PWM
40%
60%
80%
100%
Select Default FAN PWM to make
FAN speed keep the invariable
speed when temperature is below
FSC temperature target at low user
conditions. This delivers optimized
acoustic level