Intel® Server System R2600SR Setup and Service Guide
63
3.15.3
Installing the EIOM
Install the EIOM by completing the following steps:
Figure 54. Installing the EIOM
1.
Grasp the EIOM and align the four EIOM tabs with the slots in the system shuttle and lower the EIOM
into the slots. Pull the EIOM slightly towards the rear side of the system shuttle (see Number 1).
2.
Connect required cables to the EIOM by aligning the connectors and pressing
down until the connectors lock into place (see Number 2).
3.
Turn the thumbscrews clockwise to secure the EIOM (see Number 3).
3.15.4
Installing the System Shuttle
After installing the EIOM, reinstall the system shuttle.
Figure 55. Reinstalling the system shuttle
1.
Align the system shuttle with rails and pins
2.
Slide the system shuttle into the system chassis.