If more than one 8 x 2.5” backplane is being installed (R2000WTXXX only), locate the I2C jumper cable
and connect one end of the cable to the I2C-OUT connector of backplane #1 and the other end of the
cable to the I2C- IN connector of backplane #2.
Figure 21. Dual 8x2.5" Hot Swap Backplane I2C Jumper Cable Installation
SAS/SATA Data Cable connections
SAS/SATA Data cable connections will vary depending on the system configuration. This section will only
describe cable connections when using the onboard SATA controllers. For other add-in storage options,
refer to the appropriate option installation sections available in this document.
•
Locate the appropriate SAS/SATA Data cables
•
Attach the P1 end of the SAS/SATA Data cables to the mini-SAS HD connectors on the backplane
•
Route the SAS/SATA DATA cables from the backplane to the back of the system via the cable channels
next to the chassis sidewalls
Backplane #1
Backplane #2
I
2
C- IN
I
2
C - OUT
I
2
C IN
From Server Board
To Backplane #2
From Backplane #1