Intel® Server S2600WF Product Family Configuration Guide
94
4.6
2U 12 x 3.5 – R2312WFxxx SAS/SATA/NVMe* Data Cable Guide
Figure 26. R2312WFxxx SAS/SATA backplane
4.6.1
2U 12 x 3.5” - R2312WFxxx SAS/SATA/NVMe* Data Cable Guide (with no SAS Expander)
Table 56. Data cable guide (no SAS expander) for Intel® Server System R2312WFxxx
System
Configuration
Drive Support
SATA
Onboard Multi-port
SATA Ports to
Backplane (BP)
SAS
Mezzanine 12 Gb SAS ROC
Module to Backplane (BP)
SAS
12 Gb SAS RAID PCIe* add-in card to
Backplane (BP)
Up to 2 x NVMe
Onboard PCIe OCuLink to
Backplane (BP) drive bays 10 & 11
only
R2312WF…
12 x 3.5”
6 Gb SATA all drives
12 Gb SAS all drives
PCIe NVMe SFF
drives 10 & 11 only
SATA 0-3
BP 0-3
800mm HD --- HD
AXXCBL800HDHD
SATA 4-7
BP 4-7
875 mm HD --- HD
AXXCBL875HDHD
SAS Mezz
BP 4-7
875 mm HD --- HD
SAS Mezz
BP 8-11
950 mm HD ---HD
From data above, select
appropriate cable kits from
list below:
AXXCBL800HDHD
AXXCBL875HDHD
AXXCBL950HDHD
L6 systems ship with 1 each
of the cables listed.
From Riser #1
SAS PCIe
BP 4-7
1
800 or 875 mm HD --- HD
SAS PCIe
BP 8-11
875 mm HD ---HD
From Riser #2
SAS PCIe
BP 4-7
1
730 or 875 mm HD --- HD
SAS PCIe
BP 8-11
1
650 or 800 mm HD --- HD
From data above, select appropriate cable
kits (see notes below):
AXXCBL650HDHD
AXXCBL730HDHD
AXXCBL800HDHD
(1) 800mm Included in L6
AXXCBL875HDHD
(1) 875mm Included in L6
AXXCBL950HDHD
(1) 950mm included in L6)
PCIe SSD3 (CR)
BP SSD1 (CV)
600mm
AXXCBL600CVCR
PCIe SSD2 (CR)
BP SSD0 (CR)
620mm
AXXCBL620CRCR
Retimer add-in card is not
compatible with R2312WFxxx
1
1 or 2 cable lengths may be specified for a PCIe* add-in card. Generally, if the cable connector of the add-in card is located on the back edge of the card, a shorter cable is specified.
Cable connectors on the top edge or near the front of the add-in card will require the longer cable length.
Summary of Contents for R1000WF Series
Page 2: ... Blank page ...