background image

 

Intel® Server System R1000SPO 
Product Family 

Technical Product Specification 

A  document providing an  overview of product  features,  functions,  architecture,  and 
support specifications 

 

 

 

 

 

 

 

 

 

 

 

Revision 1.0 

March 2016 

 

Intel

®

 Server Boards and Systems

 

 

 

Summary of Contents for R1000SPO series

Page 1: ...em R1000SPO Product Family Technical Product Specification A document providing an overview of product features functions architecture and support specifications Revision 1 0 March 2016 Intel Server B...

Page 2: ...1 0 First External Public Release Changes Updated Illustrations Appendix E Added High Temperature Ambient Information Section 3 3 4 Added Holdup time for Fixed Power Supply Section 3 2 3 Added Informa...

Page 3: ...rse of dealing or usage in trade This document contains information on products services and or processes in development All information provided here is subject to change without notice Contact your...

Page 4: ...16 2 9 Available Rack Mounting Kit Options 16 2 10 System Level Environmental Limits 17 2 11 System Packaging 18 2 11 1 Intel Product Weight Information 18 3 System Power 19 3 1 Power Supply Configura...

Page 5: ...rformance 36 5 3 Hot Swap Drive Carriers 37 5 4 Storage Backplane Options 39 5 4 1 I2C Functionality 40 5 4 2 4 x 3 5 Drive Hot Swap Backplane Overview 40 5 4 3 8 x 2 5 Drive SAS Backplane 42 5 5 M 2...

Page 6: ...ystem R1000SPO Product Family TPS v Appendix B POST Code Diagnostic LED Decoder 62 Appendix C POST Code Errors 72 Appendix D System Cable Routing Diagrams 76 Appendix E High Temperature Ambient Info 7...

Page 7: ...l Emboss Dimensions 16 Figure 18 350W AC Fixed Power Supply 19 Figure 19 450W AC Power Supply 19 Figure 20 350W Power Supply Mechanical Drawings 20 Figure 21 450W Power Supply Mechanical drawings 21 F...

Page 8: ...48 Figure 42 Front Panel LEDs and Buttons 48 Figure 43 Add in Card Support 51 Figure 44 Riser Card Assembly 51 Figure 45 Intel I O Module Placement 52 Figure 46 Intel RMM4 Lite Activation Key Install...

Page 9: ...ower Supply 24 Table 17 AC Line Surge Transient Performance 450W Power Supply 25 Table 18 Performance Criteria 25 Table 19 Over Current Protection 350W Power Supply 26 Table 20 Over Current Protection...

Page 10: ...duct Family TPS ix Table 39 POST Progress Codes 63 Table 40 MRC Progress Codes 69 Table 41 POST Progress LED Codes 70 Table 42 POST Error Codes and Messages 72 Table 43 POST Error Beep Codes 74 Table...

Page 11: ......

Page 12: ...sure Agreement NDA with Intel and must be ordered through your local Intel representative Table 1 Reference Documents Document Title Document Classification Intel Server Board S1200SP Family BMC EPS 1...

Page 13: ...t vendor datasheets and operating parameters to determine the amount of airflow required for their specific application and environmental conditions Intel Corporation cannot be held responsible if com...

Page 14: ...upport for 2133 MT s Unbuffered DIMMs UDIMM DDR4 ECC memory Chipset Intel C236 Platform Controller Hub PCH chipset External I O connections 1x DB 15 video connector Two Gigabit Ethernet Ports Dedicate...

Page 15: ...rver Management Integrated Baseboard Management Controller IPMI 2 0 compliant Support for Intel Server Management Software On board RJ45 management port Advanced Server Management via an Intel Remote...

Page 16: ...ion testing Yes Yes Yes Test all on board I O features in all modes Yes Adapter Peripheral Compatibility Stress testing Yes Technical Support Level T1 T2 T3 See the following sections for additional i...

Page 17: ...and test operating system drivers for each of the server board s integrated controllers provided that the controller vendor has a driver available upon request Vendors will not be required by Intel t...

Page 18: ...Intel Server System R1000SPO Product Family TPS 7 Figure 2 Top Cover Features...

Page 19: ...Features Overview The following illustration provides a general overview of the server board identifying key feature and component locations Please refer to Intel Server Board S1200SP Technical Produc...

Page 20: ...System R1000SPO Product Family TPS 9 The server board includes several LEDs to identify system status The following illustrations define supported LEDs and identify their location Figure 4 On board Di...

Page 21: ...Intel Server System R1000SPO Product Family TPS 10 Figure 5 System Reset and Configuration Jumpers 2 4 Back Panel Features Figure 6 Back Panel Features...

Page 22: ...ired for use C NIC 1 2 Activity LEDs D System Cold Reset Button recessed tool required for use E System Status LED F Power Button w Integrated LED G Drive Activity LED Figure 7 Front Control Panel Opt...

Page 23: ...m cooling requirements The front bezel includes a keyed locking mechanism which can be used to prevent unauthorized access to installed storage devices and front I O ports Figure 10 Front Bezel Intel...

Page 24: ...ct Family TPS 13 Figure 12 Front Bezel Accessory with Optionally Installed Wave and ID Badge 1 Figure 13 Front Bezel Accessory with Optionally Installed Wave and ID Badge 2 Figure 14 Front Bezel Acces...

Page 25: ...Intel Server System R1000SPO Product Family TPS 14 2 8 System Dimensions 2 8 1 Chassis Dimensions Figure 15 Chassis Dimensions 1 7 43 2mm...

Page 26: ...Intel Server System R1000SPO Product Family TPS 15 2 8 2 Label Emboss Dimensions Figure 16 Label Emboss Dimensions...

Page 27: ...ex combination of unique rack offerings and custom packaging options Caution Exceeding the rail kit s specified maximum weight limit or misalignment of the server in the rack may result in failure of...

Page 28: ...to 90 non condensing with a maximum wet bulb of 28 C at temperatures from 25 C to 35 C Shock Operating Half sine 2 g 11 mSec Unpackaged Trapezoidal 25 g velocity change is based on packaged weight Pac...

Page 29: ...tel Server System R1000SPO Product Family System Integration and Service Guide for complete packaging assembly instructions NOTE The design of the inner packaging components does not prevent improper...

Page 30: ...f the total system power draw remains below the maximum power capacity of a single power supply module If a power supply fails the remaining power supply will allow the system to remain fully operatio...

Page 31: ...t various loading conditions These are provided at three different load levels 100 50 and 20 The AC power supply efficiency is tested over an AC input voltage of 230 VAC Table 7 350 Watt AC Power Supp...

Page 32: ...communications for power supply monitoring power for the Backplane and Optical Disk Drive come from the Power Distribution Board For connector pinout and power supply monitoring details please refer t...

Page 33: ...ating 125 V Figure 23 AC Power Cord 3 3 AC Power Supply Input Specifications The following sections provide the AC Input Specifications for systems configured with AC power supply modules 3 3 1 Power...

Page 34: ...rrent at high input voltage range shall be measured at 180VAC at max load 3 This requirement is not to be used for determining agency input current markings 3 3 3 AC Line Isolation Requirements The po...

Page 35: ...the AC line voltage rises above nominal voltage Table 14 AC Line Sag Transient Performance 350W Power Supply AC Line Sag 10sec interval between each sagging Duration Sag Operating AC Voltage Line Freq...

Page 36: ...pply shall comply with the limits defined in EN 55024 1998 A1 2001 A2 2003 using the IEC 61000 4 2 Edition 1 2 2001 04 test standard and performance criteria B defined in Annex B of CISPR 24 3 3 9 Fas...

Page 37: ...4 5A Table 20 Over Current Protection 450 Watt Power Supply Output Min OCP Max OCP 12V 40 A 54 A 5Vstby 3 6A 8A 3 3 13 2 Over voltage Protection OVP The power supply over voltage protection shall be...

Page 38: ...is defined in the following table Table 23 LED Indicators Power Supply Condition LED State Output ON and OK GREEN No AC power to all power supplies OFF AC present Only 12VSB on PS off or PS in Cold r...

Page 39: ..._ON 5 GND GND 17 GND GND 6 PWR 5V 18 GND GND 7 GND GND 19 GND GND 8 O PWR_GD 20 NC NC 9 PWR SB5V 21 PWR 5V 10 PWR 12V 22 PWR 5V 11 PWR 12V 23 PWR 5V 12 PWR 3 3V 24 GND GND Table 25 CPU Power Connector...

Page 40: ...ble provides air flow data associated with one of the system models within this 1U product family and is provided for reference purposes only The data was derived from actual wind tunnel test methods...

Page 41: ...operating the air duct must be installed at all times The system top cover must be installed at all times when the system is in operation in order to have proper air flow 4 2 Thermal Management Overvi...

Page 42: ...he fans are set to a fixed boost state speed Nominal A fan domain s nominal fan speed can be configured as static fixed value or controlled by the state of one or more associated temperature sensors 4...

Page 43: ...transitions If a Tcontrol SDR record does not contain a hysteresis definition for example an SDR adhering to a legacy format the BMC assumes a hysteresis value of zero 4 2 5 Thermal and Acoustic Mana...

Page 44: ...e sensor 6 On board sensor 7 Virtual sensor 8 Available only when PSU has PMBus 9 Calculated estimate A simple model is shown in the following figure which gives a high level representation of how the...

Page 45: ...em Should a fan fail the power supply will shut down Figure 26 System Fans System fans are NOT hot swap capable Each fan and is designed for tool less insertion and extraction from the system For inst...

Page 46: ...l Name Type Description 1 Ground GND Ground is the power supply ground 2 12V Power Power supply 12 V 3 Fan Tach Fan PWM In Out FAN_TACH signal is connected to the BMC to monitor the fan speed FAN_PWM...

Page 47: ...disk drive storage technology which utilizes the latest state of the art track density architectures are susceptible to the effects of system fan rotational vibration interference RVI within the serv...

Page 48: ...rive or SSD that interfaces with a backplane is mounted to a hot swap drive carrier Drive carriers include a latching mechanism used to assist with drive extraction and drive insertion Figure 30 Hot S...

Page 49: ...the 3 5 drive blank cannot be supported Each drive carrier includes separate LED indicators for drive Activity and drive Status Light pipes integrated into the drive carrier assembly direct light emit...

Page 50: ...ng up SAS LED blinks SATA LED stays off NOTE The drive activity LED is driven by signals coming from the drive itself Drive vendors may choose to operate the activity LED different from what is descri...

Page 51: ...e 5 4 1 I2C Functionality The microcontroller has a master slave I2C connection to the server board BMC The microcontroller is not an IPMB compliant device The BMC will generate SEL events by monitori...

Page 52: ...on identifies each Label Description A Power connector B SAS SATA Ports 0 3 Mini SAS HD cable connector C I2C connector Figure 35 4 x 3 5 Drive Hot Swap Backplane rear view A Power Connector The backp...

Page 53: ...The front side of the backplane includes 8 x 29 pin drive interface connectors each capable of supporting 12 Gb SAS or 6 Gb SAS SATA The connectors are numbered 0 thru 7 Data signals for each set of f...

Page 54: ...SAS SATA drives on the backplane Cables can be routed from matching connectors on the server board or add in SAS SATA RAID cards 5 5 M 2 SSD Support The system provides support for a SATA M 2 SSD sto...

Page 55: ...be compatible with SATADOM devices Table 31 SATA SATADOM capable Connector Pin out Pin IO Signal Name MH1 PWR GND 1 GND GND 2 I SATA_TX_P 3 I SATA_TX_N 4 GND GND 5 O SATA_RX_N 6 O SATA_RX_P 7 PWR GND...

Page 56: ...Intel Server System R1000SPO product family includes support for two embedded software RAID options Intel Embedded Server RAID Technology 2 ESRT2 based on LSI MegaRAID SW RAID technology Intel Rapid...

Page 57: ...the Intel C230 series chipset 6 1 1 2 Intel Embedded Server RAID Technology 2 ESRT2 Features of the embedded software RAID option Intel Embedded Server RAID Technology 2 ESRT2 include the following B...

Page 58: ...8 and 3108 4 or 8 ports and SAS SATA or SATA SKU options to support 512MB or 1GB embedded memory Intel designed flash plus optional support for Intel RAID Maintenance Free Backup Units AXXRMFBU5 NOTE...

Page 59: ...supported from these ports In addition server systems based on the Intel Server Board S1200SP cannot be USB 3 0 certified with USB 3 0 ports cabled to a front panel 7 2 Control Panel Features Figure 4...

Page 60: ...available 2 Correctable memory error threshold has been reached for a failing DDR4 DIMM in memory Sparing Mode causing Loss of Redundancy 3 Uncorrectable memory error has occurred in memory Mirroring...

Page 61: ...this motherboard Both Universal Bootloader u Boot images bad Blink Blue 6Hz Solid Amber Non recoverable condition Contact your Intelrepresentative for information on replacing this motherboard BMC in...

Page 62: ...riser card slot on the server board may damage the server board the add in card or both The system supports a single slot PCIe x16 16 lanes x16 slot riser card The riser card is mounted to a bracket...

Page 63: ...e Gen3 signals from the IIO module of the CPU 1 processor Figure 45 Intel I O Module Placement Supported I O modules include Table 35 Supported Intel I O Modules Intel Product Code Description Intel I...

Page 64: ...e Intel RMM4 lite If the attempt to access Intel RMM4 lite is successful then the BMC activates the Advanced features The following table identifies both Basic and Advanced server management features...

Page 65: ...ent mode SMM IPMB interface LAN interface that supports the IPMI over LAN protocol Remote Management Control Protocol RMCP RMCP Serial over LAN SOL ACPI state synchronization The BMC tracks ACPI state...

Page 66: ...ted on embedded NICs Dynamic Host Configuration Protocol DHCP The BMC performs DHCP supported on embedded NICs Platform environment control interface PECI thermal management support E mail alerting Em...

Page 67: ...tem has been updated to support these advanced features The embedded web server only displays US English or Chinese language output Additional features supported by the web GUI includes Presents all t...

Page 68: ...The integrated baseboard management controller has support for advanced management features which are enabled when an optional Intel Remote Management Module 4 Lite RMM4 Lite is installed The Intel RM...

Page 69: ...e boot POST and BIOS setup once BIOS has initialized video Other attributes of this feature include Encryption of the redirected screen keyboard and mouse Compression of the redirected screen Ability...

Page 70: ...equired during a server reset or power on off A BMC reset for example due to a BMC Watchdog initiated reset or BMC reset after BMC FW update will require the session to be re established KVM sessions...

Page 71: ...reset after BMC FW update will require the session to be re established The mounted device is visible to and useable by managed system s OS and BIOS in both pre boot and post boot states The mounted...

Page 72: ...during POST the LEDs display the last POST event run before the hang Only ECC Unbuffered DDR4 DIMMs UDIMMs are supported on this Product Family Clear CMOS with the AC power cord plugged in Removing AC...

Page 73: ...nostic LEDs on the back edge of the server board During a POST system hang the displayed post code can be used to identify the last POST routine that was run prior to the error occurring helping to is...

Page 74: ...8h MSB 4h 2h 1h LSB SEC Phase 01h Upper Nibble off off off off First POST code after CPU reset Lower Nibble off off off ON 02h Upper Nibble off off off off Microcode load begin Lower Nibble off off ON...

Page 75: ...ff off off ON 15h Upper Nibble off off off ON NB PEIM Lower Nibble off ON off ON 19h Upper Nibble off off off ON SB PEIM Lower Nibble ON off off ON MRC Process Codes MRC Progress Code Sequence is exec...

Page 76: ...SMM Init Lower Nibble ON off ON off 70h Upper Nibble off ON ON ON DXE SB Init Lower Nibble off off off off 71h Upper Nibble off ON ON ON DXE SB SMM Init Lower Nibble off off off ON 72h Upper Nibble o...

Page 77: ...Upper Nibble ON off off off DXE USB start Lower Nibble ON off ON off 8B Upper Nibble ON off off off DXE USB reset Lower Nibble ON off ON ON 8C Upper Nibble ON off off off DXE USB detect Lower Nibble O...

Page 78: ...wer Nibble ON ON off off 9Dh Upper Nibble ON off off ON DXE Exit Boot Services Lower Nibble ON ON off ON C0h Upper Nibble ON ON off off RT Set Virtual Address Map Begin Lower Nibble off off off off C1...

Page 79: ...er Nibble off ON off off PEIM which detected forced Recovery condition Lower Nibble off ON ON off 47h Upper Nibble off ON off off PEIM which detected User Recovery condition Lower Nibble off ON ON ON...

Page 80: ...modes and save rank information Lower Nibble off ON off off B5h Upper Nibble ON off ON ON Program registers on the channel level Lower Nibble off ON off ON B6h Upper Nibble ON off ON ON Perform the JE...

Page 81: ...Nibble 8h MSB 4h 2h 1h LSB Lower Nibble 8h MSB 4h 2h 1h LSB MRC Fatal Error Codes E8h Upper Nibble ON ON ON off No usable memory error 01h No memory was detected from the SPD read or invalid config th...

Page 82: ...IMM configuration population error 01h Different DIMM types UDIMM RDIMM LRDIMM are detected installed in the system 02h Violation of DIMM population rules Lower Nibble ON ON off ON 03h The 3rd DIMM sl...

Page 83: ...een and an error is logged to the SEL The POST Error Pause option setting in the BIOS setup determines whether the system pauses to the Error Manager for this type of error so the user can take immedi...

Page 84: ...E Failed to respond Major 84F2 Baseboard management controller failed to respond Major 84F3 Baseboard management controller in update mode Major 84F4 Sensor data record empty Major 84FF System event l...

Page 85: ...p codes to inform users on error conditions The beep code is followed by a user visible code on the POST Progress LEDs Table 43 POST Error Beep Codes Beeps Error Message POST Progress Code Description...

Page 86: ...ket is empty CPU1 socket is empty or sockets are populated incorrectly CPU1 must be populated before CPU2 1 5 2 4 MSID Mismatch MSID mismatch occurs if a processor is installed into a system board tha...

Page 87: ...Intel Server System R1000SPO Product Family TPS 76 Appendix D System Cable Routing Diagrams Figure 48 Internal Cable Routing...

Page 88: ...les AXX10GBTWLIOM and AXX2FDRIBIOM are only supported in the specified base system model configured with 120W processors and DRx4 memory 5 Use of the designated PCIe slot is limited to add in cards th...

Page 89: ...IMM up to 2133MHz Add in Cards See note 5 On Riser Card SAS and I O Modules See Note 4 Intel Integrated RAID Modules Mezzanine cards AXX10GBTWLIOM3 Dual 10GBASE T I O Module AXX4P1GBPWLIOM Quad Port 1...

Page 90: ...nced Technology Attachment EFI Extended Firmware Interface UEFI Unified Extended Firmware Interface OS Operating System CV Compatibility Validation NMI Non Maskable Interrupt NIC Network Interface Car...

Page 91: ...al Serial Bus KVM Keyboard Video and Mouse Interface RMM4 Remote Management Module FRU Field Replaceable Unit SEL System Event Log SMS System Management Software RMCP Remote Management Control Protoco...

Page 92: ...Intel Server System R1000SPO Product Family TPS 81...

Page 93: ...______________________________________________________________________________ __________________________________________________________________________________________________ ______________________...

Reviews: