Hardware Installations and Upgrades
Intel
®
Server Chassis P4000M Service Guide
43
Installing Second 8x2.5'' Hotswap Hard Disk Drive Cage
Assembly
CAUTION
It is critical that you connect the SAS/SATA data cables correctly from the SAS/SATA backplane to
your server board or RAID controller card. Failure to do so may result in data loss.
1. Observe the safety and ESD precautions at the beginning of this book.
2. Power down the server and unplug all peripheral devices and the AC power cable.
3. Remove the chassis cover. For instructions, see “Removing the Chassis Cover”.
4. Remove the front bezel if it is installed. For instructions, see “Removing the Front Bezel (Pedestal
Only)”.
5. Install bottom 8x2.5'' Hotswap Hard Drive Cage.
1)
Slide the 8x2.5'' Hotswap Drive Cage into the slot (see letter
A
).
2)
Secure the Hard Drive Cage with the Screw (see letter
B
).
Figure 66. Installing the Second 8x2.5
''
Hotswap Hard Drive Cage Assembly
6. Make the backplane and server board/RAID controller card cable connections. Refer to the
documentation that came with your server board and/or RAID controller card for instructions on
connecting backplane cables to your server board or RAID controller card.
1)
Connect an I
2
C cable to the I2C_IN connector of the bottom backplane (see letter
A
)
2)
Connect MiniSAS data cables to the Mini SAS connector of the backplane (see letter
B
). There
are multiple MiniSAS connectors on the backplanes. The figure show connecting to one of them.
Connect them as needed.
3)
Connect power cable to the power connector (see letter
C
).
4)
Connect an I
2
C cable to the I2C_OUT connector of the bottom backplane and the I2C_IN
connector of the top backplane (see letter
D
).
5)
Install the front bezel. For instructions, see “Installing the Front Bezel (Pedestal Only)”.
Summary of Contents for P4000M
Page 14: ......