Hardware Installations and Upgrades
36
Intel
®
Server Chassis P4000M Service Guide
Figure 57. 8x3.5
''
Hot Swap Backplane Cable Connections
7. Install the front bezel. For instructions, see “Installing the Front Bezel (Pedestal Only)”.
8. Install the air duct if the air duct is removed. For instructions, see “Installing the Airduct”.
9. Install the chassis cover. For instructions, see “Installing the Chassis Cover”.
10. Plug all peripheral devices and the AC power cable into the server.
11. Power up the server.
Removing and Installing 8x3.5'' Hotswap Backplane
/
NOTE
This procedure applies only to the Intel
®
Server Chassis P4000M family with 8x3.5'' hotswap hard
disk drive cage configuration.
Removing 8x3.5'' Hotswap Backplane
1. Observe the safety and ESD precautions at the beginning of this book.
2. Power down the server and unplug all peripheral devices and the AC power cable.
3. Remove the chassis cover. For instructions, see “Removing the Chassis Cover”.
4. Remove the front bezel if it is installed. For instructions, see “Removing the Front Bezel (Pedestal
Only)”.
5. Remove the 8x3.5'' Hotswap Hard drives cage. For instructions, see “Removing 8x3.5'' Hotswap Hard
Drive Cage Assembly”.
6. Remove all hotswap drive carriers, regardless of whether or not a drive is installed in the carrier.
7. Remove the screws on the backplane (see letter
A
).
8. Push the backplane (see letter
B
) and remove the backplane from the cage (see letter
C
).
Summary of Contents for P4000M
Page 14: ......