Hardware Installations and Upgrades
34
Intel
®
Server Chassis P4000M Service Guide
10. Install the chassis cover. For instructions, see “Installing the Chassis Cover”.
11. Plug all peripheral devices and the AC power cable into the server.
12. Power up the server.
Removing and Installing 8x3.5'' Hotswap Hard Drive
Cage Assembly
/
NOTE
This procedure applies only to the Intel
®
Server Chassis P4000M family with 8x3.5'' hotswap hard disk
drive cage configuration.
Removing 8x3.5'' Hotswap Hard Drive Cage Assembly
1. Observe the safety and ESD precautions at the beginning of this book.
2. Power down the server and unplug all peripheral devices and the AC power cable.
3. Remove the chassis cover. For instructions, see “Removing the Chassis Cover”.
4. Remove the front bezel if it is installed. For instructions, see “Removing the Front Bezel (Pedestal
Only)”.
5. Disconnect the power and data cables to the backplane.
6. Use screwdriver to release the hotswap hard drive cage (see letter
A
) from the chassis and remove
the hotswap hard drive cage (see letter
B
).
Figure 55. Removing the 8x3.5
''
Hotswap HDD Cage Assembly
Summary of Contents for P4000M
Page 14: ......