Hardware Installations and Upgrades
Intel
®
Server Chassis P4000M Service Guide
21
Removing the Airduct
1. Observe the safety and ESD precautions at the beginning of this book.
2. Power down the server and unplug all peripheral devices and the AC power cable.
3. Remove the chassis cover. For instructions, see “Removing the Chassis Cover”.
4. Remove the airduct.
Replacing the Fixed Fan
/
NOTE
Please pay attention to the fan cable connector color. The fan with blue connector should be installed in
fan 2 bracket and the fan with white connector should be installed in fan 1 bracket. The fan numbering is
inscribed on the chassis.
This procedure applies only to the Intel
®
Server Chassis P4000M family with fixed fan configuration.
Removing the Fixed Fan
1. Observe the safety and ESD precautions at the beginning of this book.
2. Power down the server and unplug all peripheral devices and the AC power cable.
3. Remove the chassis cover. For instructions, see “Removing the Chassis Cover”.
4. Remove the air duct if the air duct is installed. For instructions, see “Removing the Airduct”.
5. Disconnect the appropriate fan power cable from the server board (see letter
A
).
Figure 32. Disconnecting the fan power cable from the server board