Getting Started
Warning:
It is critical that each V(I/O) plane does not have both its 3.3 V and 5 V shunts loaded
simultaneously. Doing so causes permanent damage to the midplane and could pose a fire hazard.
2.4.4
Disabling the Power Standby Switch
Removing jumper J7 from both power trays disables the power standby switch.
illustrates the location of the J7 jumpers.
Figure 14. ZT 5085 V(I/O) Shunt Locations