Intel® Server System M70KLP Family Service Guide
49
Intel® RAID Maintenance Free Backup Unit (RMFBU) accessory kits include several components, including a
molded plastic mounting bracket. In this system, the mounting bracket is not used.
Figure 60. Intel® RMFBU Accessory Kit
Required Tools and Supplies
•
Anti-static wrist strap and ESD safe workbench (recommended)
System Prerequisites
•
The system must be powered off and AC Power cord(s) disconnected
•
RAID Card is installed
•
Remove the system top cover
–
See
Section 2.1
3.7.1
RMFBU Installation
Each RMFBU is secured to the top side of the air duct using hook and loop straps pre-mounted to the air
duct.
Note:
The Standard air duct supports up to three RMFBUs. Two are stacked together in the mounting
location closest to the back edge of the air duct. Securing the stacked RMFBUs is the same as described
below.
Figure 61. Intel® RMFBU Placement