Intel® Server System M70KLP Family Service Guide
32
3.2
Add-in Card Installation and Removal
PCIe* add-in cards can be installed to any available PCIe add-in cards slots found on the server board and/or
to installed riser cards (if present). No tools are required to install or remove a PCIe add-in card.
3.2.1
PCIe* Add-in Card Installation - Server Board Add-in slots
The server board can support vertically mounted Half-Height, Half-Length PCIe add-in cards.
Required Tools and Supplies
•
Anti-static wrist strap and conductive workbench pad (recommended)
System Prerequisites
•
The system must be powered off and AC Power cord(s) disconnected
Figure 33. Add-in Card to Server Board - Filler Plate Removal
1.
Lift open the silver filler plate retention latch on the top edge of the back panel (see Letter A).
2.
Remove the filler plate for the desired add-in slot (see Letter B).
Figure 34. Add-in Card to Server Board - Card Installation
3.
Align the edge connector of the add-in card over the desired add-in slot (see Letter C).
4.
Insert the add-in card into the slot using even downward pressure until the card is fully seated.
5.
Close the filler plate retention latch until it snaps into place (see Letter D).
Summary of Contents for M70KLP Series
Page 2: ...Intel Server System M70KLP Family Service Guide Blank page...
Page 94: ...Intel Server System M70KLP Family Service Guide 92 1 2 3 4 5 6 1 2 3...
Page 95: ...Intel Server System M70KLP Family Service Guide 93 1 2 3 4 5...
Page 96: ...Intel Server System M70KLP Family Service Guide 94 7 8 9 10 11 12 4 5 6...
Page 97: ...Intel Server System M70KLP Family Service Guide 95 6 7 8 9 10...
Page 106: ...Intel Server System M70KLP Family Service Guide 104 1 2 3 4 5 ESD 6 1 2 3...
Page 107: ...Intel Server System M70KLP Family Service Guide 105 1 2 3 4 5...