Intel® Server System M50FCP1UR System Integration and Service Guide
46
4.
Locate the TPM module connector on the server board.
5.
Insert the plastic stand-off into the mounting hole in the server board (see Letter A).
6.
Place the TPM module over the connector and confirm the orientation of the module.
7.
Press the module down onto the connector (see Better B).
8.
Secure the TPM module to the stand-off with the tamper resistant fastener screw (see Letter C).
9.
Reinstall the system top cover (see
Section 3.1.2
3.8
Intel® RAID Maintenance Free Backup Unit (RMFBU) Installation
This section provides instructions to install an RMFBU bracket and assembly in the system. Refer to the
Intel®
Server M50FCP Family Configuration Guide
for available Intel RAID card options.
Required Tools and Supplies
•
Anti-static wrist strap and conductive workbench pad (recommended)
•
Phillips* head screwdriver #1
The RMFBU assembly has the following elements:
•
RMFBU Mounting Plate
•
RMFBU plastic housing
•
RMFBU plastic housing latch
•
RMFBU super-capacitor
The RMFBU mounting plate and housing assembly are installed in between the system fans and hot-swap
backplane.
The following three elements need to be assembled before attaching them to the mounting plate.
Figure 51. Installing Latch on the Plastic Case
1.
Insert the plastic housing latch into the opening on the plastic housing (see Letter A).
2.
Carefully lift on the latch holder (see Letter B) and insert the latch into the opening until it clicks into
place (see Letter C).
3.
Bring the latch down until it is aligned vertically (see Letter D).
Figure 52. Insert Super Cap
Summary of Contents for M50FCP1UR
Page 2: ...2 This page intentionally left blank...
Page 118: ...Intel Server System M50FCP1UR System Integration and Service Guide 118 1 2 3 4 5 6 1 2 3...
Page 119: ...Intel Server System M50FCP1UR System Integration and Service Guide 119 1 2 3 4 5...
Page 120: ...Intel Server System M50FCP1UR System Integration and Service Guide 120 7 8 9 10 11 12 4 5 6...
Page 121: ...Intel Server System M50FCP1UR System Integration and Service Guide 121 6 7 8 9 10...