Intel® Server System M50FCP1UR System Integration and Service Guide
27
Figure 18. PHM Alignment with Socket Assembly
1.
Set all four anti-tilt wires on the heat sink to the inward position (see Letter A in
Figure 19
).
2.
Align the Pin 1 indicators of the processor carrier clip and processor with the Pin 1 indicator on the
bolster plate located around the processor socket.
Caution:
Processor socket pins are delicate and bend easily. Use extreme care when placing the PHM
onto the processor socket. Do not drop it.
Figure 19. PHM Installation onto Server Board
3.
Holding the PHM horizontally, carefully lower it onto the bolster plate’s alignment pins (see Letter B).
4.
Set all four anti-tilt wires on the heat sink to the outward position. See Letter D in
Figure 19
.
5.
(EVAC Heat Sink Only) Using a Phillips #2 screwdriver, tighten the heat sink extension screws. See
Letter C in
Figure 19
.