Intel® Server System M50CYP2UR Family System Integration and Service Guide
61
3.5.6
OCP* Adapter with Internal Lock Installation
All L6 and L9 integrated systems come with an internal lock on the OCP* rail. This lock is a piece of blue
plastic. The OCP* rail in the system has a dedicated space to accommodate the lock. The lock can be
mounted on the rail in two different orientations. When the keying features of the lock are facing up, it is in
an unlocked orientation. When the keying features are facing down, it is in a locked orientation. A lock
symbol is included in each side of the plastic lock to indicate its orientation. The following figure shows the
features of the lock.
Figure 66. Internal Lock with Unlock and Lock Orientation
Figure 67. OCP* Adapter with Internal Lock Installation
1.
Power off the system and disconnect the power cable(s).
2.
Remove the system top cover (see
Section 3.1.1
).
3.
Remove the air duct (see
Section 3.2.1
4.
Remove any riser card assembly above the OCP* adapter area, if present (see
Section 3.3.1
Note:
In the default shipping configuration, the internal lock is set to the unlock orientation.
5.
Squeeze the two hooks of the internal lock and pull it out (see Letter A).
6.
Align the OCP* adapter with the open OCP* bay slot and push forward until the connectors make secure
contact (see Letter B).
7.
Reinstall the internal lock with the lock orientation (see Letter C).