Intel® Server System M50CYP1UR Family System Integration and Service Guide
39
3.2.4
Add-in Card Assembly Installation
–
Riser Slot #1, Riser Slot #2, and PCIe* Interposer
Riser Slot
Figure 30. Add-in Card Assembly Installation
1.
Power off the system and disconnect the power cable(s).
2.
Remove the system top cover (see
Section 3.1.1
).
3.
Position the add-in card
assembly’s
edge connector over the riser slot on the server board.
4.
Align the two key slots on the back edge of the add-in card assembly with the mounting keys on the back
of the chassis.
5.
Once aligned, press the add-in card assembly straight down into the riser slot (see Letter A).
6.
Using the fastener screws, secure the add-in card assembly to the system (see Letter B). Tighten to
5 in-lb.
7.
Connect any cables to the add-in card that are required. See your add-in card documentation for
additional information.
8.
Reinstall the system top cover (see
Section 3.1.2
).
3.3
2.5”
SSD Drive Removal, Assembly, and Installation
The Intel® Server System M50CYP1UR family has front drive bay chassis opt
ions that support 2.5” form
factor drives (SSDs only). Additionally, 7 mm
thick SSDs with a form factor of 2.5” are supported when used
in conjunction with the supplied drive blank for 2.5” bays.
The 2.5” drive bay options also support 15 mm
drives. Each storage drive that interfaces with a backplane is mounted to a tool-less, non-detachable,
mounting rail. The front drives are hot swappable.
This section provides instructions for drive assembly, drive installation into the chassis, and drive removal
from the chassis.
identifies the drive bay components.
Required Tools and Supplies
•
Anti-static wrist strap and conductive workbench pad (recommended)