Intel® Server System M20NTP1UR - System Integration and Service Guide
25
Caution:
Processor socket pins are delicate and bend easily. Use extreme care when placing the PHM
onto the processor socket. Do not drop it.
2.
Install the Processor Heat Sink Module (PHM) on to the processor socket assembly
Figure 16. PHM Installation onto Server Board
•
Set all four anti-tilt wires on the heat sink to the inward position (see Letter “A”).
•
Carefully lower the PHM over the four bolster plate alignment pins (see Letter “B”).
•
Ensure the PHM is sitting flat and even on the bolster plate.
•
Set all four anti-tilt wires on the heat sink to the outward position (see Letter “C”).
3.
Secure the PHM to the bolster plate
Figure 17. Tighten Heat Sink Fasteners
•
Using a T30 Torx* screwdriver, tighten the heat sink fasteners to 8 in-lb.
•
Repeat the procedure for the second processor