Intel® Server Board S2600TP and Intel® Compute Module HNS2600TP Product Family
7
1.7
Configuration and Recovery Jumpers
Jumper Name
Description
BMC Force Update (J7A2)
If pins 2-3 are selected, the Integrated BMC Force Update
Mode is enabled. These pins should be selected on 1-2 for
normal system operation.
BIOS Default (J7A3)
If pins 2-3 are selected, the BIOS settings are restored to the
factory defaults on the next reset. These pins should be
selected on 1-2 for normal system operation.
BIOS Recovery (J7A7)
If the system BIOS is corrupted, an onboard backup copy of
the BIOS can be loaded using the BIOS Recovery Jumper. To
load the backup BIOS image, move the jumper from pins 1-2
(default) to pins 2-3, and power on the system. The system will
boot to the backup BIOS image. These pins should be selected
on 1-2 for normal system operation.
Password Clear (J7A6)
If pins 2-3 are selected, administrator and user passwords are
cleared within five to ten seconds after the system is powered
on. These pins should be selected on 1-2 for normal system
operation.
ME Force Update (J5D2)
If pins 2-3 are selected, the ME Force Update Mode is enabled.
These pins should be selected on 1-2 for normal system
operation.
Figure 11.
Configuration and Recovery Jumpers