Appendix A: Technical Reference
Intel
®
Server System H2000JF Family Service Guide
61
Appendix A: Technical Reference
Power Supply Input Voltages
Table 8. CRPS Input Voltage
Parameter
Min
Rated
Max
Start up VAC
Power Off VAC
110V
AC
90 V
rms
100-127 V
rms
140 V
rms
85 V
AC
± 4V
AC
70V
AC
±5V
AC
220V
AC
180 V
rms
200-240 V
rms
264 V
rms
Frequency
47 Hz
50/60 Hz
63 Hz
Power Supply Output Voltages
Table 9. CRPS Output Voltage
Parameter
Min
Nom
Max
Unit
Tolerance
+12V
STB
+11.40V
+12.000V
+12.60V
Vrms
±5%
+12V
+11.40V
+12.000V
+12.60V
Vrms
±5%
System Environmental Specifications
The following table defines the system level operating and non-operating environmental limits.
Table 10. System Environmental Limits Summary
Parameter
Limits
Operating Temperature
+10°C to +35°C with the maximum rate of change not to exceed 10°C per hour.
Non-Operating Temperature
-40°C to +70°C
Non-Operating Humidity
90%, non-condensing at 35°C
Acoustic noise
Sound power:
3.5” HDD SKU: 6.9BA at idle and 7.4BA at active mode
2.5” HDD SKU: 6.5BA at idle and 7.07BA at active mode
In typical office ambient temperature (23 +/- 2 degrees C).
Shock, operating
Half sine, 2g peak, 11 milliseconds
Shock, unpackaged
Trapezoidal, 25g, velocity change 205 inches/second (80 lbs to < 100 lbs)
Shock, packaged
Non-palletized free fall in height 18 inches (80 lbs to < 100 lbs)