Intel® Server D50TNP Family Integration and Service Guide
66
3.4.2
Closing the Top Tray
Figure 68
.
Removing the Air Duct
1.
Push up the front edge of the top tray just slightly until the lock releases.
2.
Push the handle bar down (see Letter A) with one hand. Hold the front edge of the top tray with the other
hand and lower it (see Letter B).
3.
Lock the latches on both sides of the top tray (see Letter C).
3.5
Add-in Card Option Installation
The Intel® Server System D50TNP family supports either up to two (1U modules) or up to four (2U modules)
low-profile PCIe* add-in cards.
This section provides assembly and installation procedures for modules that require low-profile add-in card
installation. The following procedures apply to both 1U and 2U modules in both air-cooled and liquid-
cooled configurations.
Note:
The D50TNP Accelerator Module has additional support for up to four full height, full length, double
width PCIe* accelerator cards. Follow the installation procedures in
Section 3.7
Available Riser Card Options:
•
1U riser card (installed in 1U riser assembly) for 1U module using Intel® Server Board D50TNP1SB
•
1U riser card (installed in 1U riser assembly) for 1U module using Intel® Server Board D50TNP1SBCR
•
2U riser card (installed in 2U riser assembly) for 2U module