Intel® Server D50TNP Family Integration and Service Guide
206
3.
Remove the riser assemblies from the module.
4.
Move the “
SVN_Bypass
”
(J16) jumper from pins 1
–
2 (default) to pins 2
–
3 (SVN Bypass).
5.
Reinstall the riser assemblies.
6.
Reinstall the module in the chassis.
7.
Power on the Module. The system automatically boots to the EFI shell.
8.
Update the BIOS using the recovery BIOS update instructions provided with the system update package.
9.
After the BIOS update has successfully completed, power down the module.
10.
Remove the module from the chassis and remove the riser assemblies from the module.
11.
Move the
“
SVN_Bypass
”
(J16) jumper back to pins 1
–
2 (default).
12.
Reinstall the module in the chassis.
13.
Power on the module. During POST, press
<F2>
to access the BIOS Setup utility to configure and save
desired BIOS options.
D.6 BMC SVN Downgrade (J33)
When this jumper is moved from its default pin position (pins 1
–
2), it allows the module BMC firmware in the
PFR-controlled BMC capsule file to be downgraded to lower Security Version Number (SVN). This jumper is
used when there is a need for the module to power on using a BMC revision with lower SVN.
Caution:
Downgrading to a BMC version with lower SVN may result in the loss of functionality and security
features that are present in a higher SVN but was not implemented in the lower SVN.
Caution:
When downgrading to an older version of BMC, modules may end up with a firmware stack
combination that is not supported, and therefore could experience unpredictable behavior.
Note:
Latest system update packages are included in the SUP posted to Intel’s download ce
To use the BMC SVN Downgrade jumper, perform the following steps:
1.
Power down the Intel® D50TNP Module.
2.
Remove the module from the chassis
3.
Remove the riser assemblies from the module.
4.
Using a tweezers, move the BMC SVN Downgrade jumper (J33) from pins 1
–
2 (default) to pins 2
–
3
(Enabled).
5.
Reinstall the riser assemblies.
6.
Reinstall the module in the chassis.
7.
Power on the Module. The system automatically boots to the EFI shell.
8.
Update the BMC using the recovery BMC update instructions provided with the system update package.
9.
After the BMC update has successfully completed, power down the module.
10.
Remove the module from the chassis and remove the riser assemblies from the module.
11.
Using a tweezers, move the BMC SVN Downgrade jumper (J33) jumper back to pins 1
–
2 (default).
12.
Reinstall the riser assemblies
13.
Reinstall the module in the chassis.
14.
Power on the module.