Hardware Installations and Upgrades
Intel
®
Compute Module MFS2600KI User Guide
13
Figure 10. Installing Processor – Remove the Cover
5.
Close the Load Plate. Carefully lower the load plate over the processor.
Figure 11. Installing Processor – Close the Load Plate
6.
Latch the Locking Lever. Push down on the locking lever on the
CLOSE 1st
side (see letter
A
).
Slide the tip of the lever under the notch in the load plate (see letter
B
). Make sure the load
plate tab engages under the socket lever when fully closed. Repeat the steps to latch the locking
lever on the other side (see letter
C
). Latch the levers in the order as shown.
Figure 12. Installing Processor – Latch the Locking Lever
Installing Processor Heatsink(s)
1.
Remove the protective film on the TIM if present (see letter
A
).
2.
Align heatsink fins to the front and back of the chassis for correct airflow. Airflow goes from
front-to-back of chassis (see letter
B
).
Each heatsink has four captive fasteners and should be tightened in a diagonal manner using the
following procedure:
3.
Using a #2 Phillips* screwdriver, start with screw 1 and engage screw threads by giving it two
rotations and stop (see letter
C
). (Do not fully tighten.)
4.
Proceed to screw 2 and engage screw threads by giving it two rotations and stop (see letter
D
).
Similarly, engage screws 3 and 4.