Case Temperature Reference Metrology
Thermal and Mechanical Design Guidelines
83
Appendix D
Case Temperature
Reference Metrology
D.1
Objective and Scope
This appendix defines a reference procedure for attaching a thermocouple to the IHS
of a 775-land LGA package for T
C
measurement. This procedure takes into account the
specific features of the 775-land LGA package and of the LGA775 socket for which it is
intended. The recommended equipment for the reference thermocouple installation,
including tools and part numbers are also provided. In addition a video
Thermocouple
Attach Using Solder – Video CD-ROM
is available that shows the process in real time.
The following supplier can do machining the groove and attaching a thermocouple to
the IHS followed by the reference procedure. The supplier is listed the table below as
a convenience to Intel’s general customers and the list may be subject to change
without notice.
Supplier
Contact
Phone
Address
THERM-X OF
CALIFORNIA
Ernesto
B Valencia
510-441-7566
Ext. 242
1837 Whipple Road,
Hayward, Ca 94544
D.2
Supporting Test Equipment
To apply the reference thermocouple attach procedure, it is recommended to use the
equipment (or equivalent) given in the table below.
Item
Description
Part Number
Measurement and Output
Microscope
Olympus* Light microscope or equivalent
SZ-40
DMM
Digital Multi Meter for resistance measurement
Fluke 79 Series
Thermal Meter
Hand held thermocouple meter
Multiple Vendors
Solder Station (see note 1 for ordering information)
Heater Block
Heater assembly to reflow solder on IHS
30330
Heater
WATLOW120V 150W Firerod
0212G G1A38-
L12
Transformer
Superior Powerstat transformer
05F857
Summary of Contents for CELERON PROCESSOR E3000 - THERMAL AND MECHANICAL DESIGN
Page 24: ...Processor Thermal Mechanical Information 24 Thermal and Mechanical Design Guidelines ...
Page 80: ...Heatsink Clip Load Metrology 80 Thermal and Mechanical Design Guidelines ...
Page 82: ...Thermal Interface Management 82 Thermal and Mechanical Design Guidelines ...
Page 108: ...Fan Performance for Reference Design 108 Thermal and Mechanical Design Guidelines ...