82562EZ(EX)/82547GI(EI) Dual Footprint Design Guide
57
Appendix B GigConf.exe Register Settings for 82547GI(EI)
Devices
The following steps describe the indirect probing test method using GigConf.exe for 82547GI(EI)
devices.
1. Boot to DOS using a DOS Boot Diskette.
2. Launch Gigconf from the diskette (gigconf.exe).
3. Select the Intel network connection to be measured.
a. If multiple adapters are installed, use the arrow keys to navigate to highlight the selected
adapter and press Enter.
4. Select Registers by pressing “R”.
5. Select PHY Registers by pressing “P”.
6. Use the arrow keys to navigate to the value listed next to address 0000.
7. Press Enter when the value is highlighted and then use Backspace to clear out the current
value.
8. Type “0100” for the value and then press Enter.
9. Navigate to the value listed next to address 0012.
10. Press Enter to select the highlighted value and use Backspace to clear the current value.
11. Type “8000” for the value and then press Enter.
12. Navigate to the Set Address field on the right side of the screen (use the right arrow key)
13. Press Enter to select the highlighted value and then use Backspace to clear out the current
value.
14. Type “4011” for the value and then press Enter.
This changes the PHY register screen and updates it with new addresses and values.
15. Use the arrow keys to navigate to the value for address 4011.
16. Press Enter when the value is highlighted and then use Backspace to clear the current value.
17. Type “8000” for the value and then press Enter.
18. Use the right arrow key to navigate to the Set Address field on the right side of the screen.
19. Press Enter when the value is highlighted and use Backspace to clear the current value.
20. Enter “2F5B” (capital letters are not required) for the address and then press Enter.
21. Use the arrow keys to navigate to the value for address “2F5B”.
22. Press Enter when the value is highlighted and then use Backspace to clear the current value.
23. Type “0003” for the value and then press Enter.
24. Use the right arrow key to navigate to the Set Address field on the right side of the screen.
25. Press Enter when the value is highlighted and then use Backspace to clear the current value.
Summary of Contents for 82547EI
Page 1: ...82562EZ EX 82547GI EI Dual Footprint Design Guide Networking Silicon 317520 002 Revision 2 2...
Page 4: ...iv 82562EZ EX 82547GI EI Dual Footprint Note This page is intentionally left blank...
Page 8: ...viii 82562EZ EX 82547GI EI Dual Footprint Design Guide Note This page intentionally left blank...
Page 14: ...82562EZ EX 82547GI EI Dual Footprint Design Guide 6 Note This page intentionally left blank...
Page 28: ...82562EZ EX 82547GI EI Dual Footprint Design Guide 20 Note This page intentionally left blank...
Page 40: ...82562EZ EX 82547GI EI Dual Footprint Design Guide 32 Note This page intentionally left blank...
Page 42: ...82562EZ EX 82547GI EI Dual Footprint Design Guide 34 Note This page intentionally left blank...
Page 58: ...82562EZ EX 82547GI EI Dual Footprint Design Guide 50 Note This page intentionally left blank...
Page 66: ...82562EZ EX 82547GI EI Dual Footprint Design Guide 58 Note This page intentionally left blank...