1000BASE-T/100BASE-TX/10BASE-T Physical Layer Compliance Tests Manual
Intel Confidential
23
1000BASE-T MDI Return Loss
6
1000BASE-T MDI Return Loss
IEEE Standard 40.8.3.1
6.1
Test Purpose
To measure the return loss on all four channels at the MDI.
6.2
Specification
The return loss for each transmit/receive channel shall be:
≥
16 dB from 1 MHz to 40 MHz, and
≥
10 – 20LOG(f/80)dB from 40 MHz to 100 MHz, where f is in MHz.
6.3
Test Equipment
•
Vector network analyzer
•
BNC cable with 50-ohm characteristic impedance
•
UUT with gigconf.exe test software.
6.4
Test Fixtures
•
Fixture 40.8.3.1.A, Balun test fixture (
•
Fixture 40.8.3.1.B, calibration standards (
•
Fixture 40.8.3.1.C, square pin fixture (
)
6.5
Test Procedure
1. Connect the equipment as shown in the figure below. Note: do not connect test fixture
40.8.3.1.C to the UUT's RJ-45 at this time. See
for more details.