DMX CONNECTIONS
Use a standard 5 pin XLR, DMX data cable to
connect the
dmx-IT
to your DMX receivers.
(
Pins 1-3 are used, 4 & 5 are not connected to the
dmx-IT
)
Note:
dmx-IT
products comply with the DMX512
standard as defined by the USITT specification and
use a 5 pin XLR for interface connection and data
transmission to DMX receivers. The wire type for
DMX512 cable must be data cable designed for
EIA485. This cable is low capacitance, twisted pair,
shielded, and designed for high speed data. There
are many brands and types that will work reliably.
Standard pre-built cables can be purchased from
any theatrical lighting supplier. Conversion to 3 pin
XLR and use of microphone cable is known to be
problematic and not recommended.
SPECIFICATIONS
Size: 7.6" L, 1.3" H(front), 1.75" H(rear), 3.75" W
(19.3cm L, 3.3cm H(front), 4.4cm H(rear), 9.5cm W)
Net Weight: 1.5 lbs. (0.68kg)
Power requirements: 4 AA alkaline batteries (not
included) and/or a 9-12V 100mA AC adapter
(included), with a standard 2.1mm x 5.5mm barrel
connector.
Adapter polarity may be either center positive or
center negative.
dmx-IT
data control timing accuracy meets or
exceeds USITT standards and provides highly stable
outputs with no jitter or bobble headed values.
The starting channel assign switches are read during
the power up cycle of the
dmx-IT
12
. Changing
the switch settings with power on will have no effect
until the power is cycled off, then on again.