Integrated Controls DMX-IT 12 User Manual Download Page 1

Unit is shown as shipped with starting channel set to 1 

DMX-IT 12 

Palm-Top Lighting Console

 

USER MANUAL 

Integrated Controls, Inc.

 

Designed and manufactured by: 

Integrated Controls, Inc. 

2851 21st Street 

San Francisco, CA 94110 

Tel: 415-647-0480 Fax: 415-647-3003 

email: [email protected]

 

website: http://www.dmxit.com

 

Dealer 

Integrated Controls, Inc. 

DMX-IT Service Policy Available on website 

DMX CONNECTIONS 

Use a standard 5 pin XLR, DMX data cable to 
connect the

 

dmx-IT 

to your DMX receivers. 

(

Pins 1-3 are used, 4 & 5 are not connected to the 

dmx-IT

Note: 

dmx-IT

 

products comply with the DMX512 

standard as defined by the USITT specification and 
use a 5 pin XLR for interface connection and data 
transmission to DMX receivers. The wire type for 
DMX512 cable must be data cable designed for 
EIA485. This cable is low capacitance, twisted pair, 
shielded, and designed for high speed data. There 
are many brands and types that will work reliably. 
Standard pre-built cables can be purchased from 
any theatrical lighting supplier. Conversion to 3 pin 
XLR and use of microphone cable is known to be 
problematic and not recommended. 

 

 

 

SPECIFICATIONS 

Size: 7.6" L, 1.3" H(front), 1.75" H(rear), 3.75" W 
(19.3cm L, 3.3cm H(front), 4.4cm H(rear), 9.5cm W) 
Net Weight: 1.5 lbs. (0.68kg) 
Power requirements: 4 AA alkaline batteries (not 
included) and/or a 9-12V 100mA AC adapter 
(included), with a standard 2.1mm x 5.5mm barrel 
connector. 
Adapter polarity may be either center positive or 
center negative. 

dmx-IT

 

data control timing accuracy meets or 

exceeds USITT standards and provides highly stable 
outputs with no jitter or bobble headed values. 

The starting channel assign switches are read during 
the power up cycle of the 

dmx-IT

 

12

. Changing 

the switch settings with power on will have no effect 
until the power is cycled off, then on again.

 