background image

LED RECESSED LIGHTS 2015B

INSTALLATION INSTRUCTIONS 

IMPORTANT SAFEGUARDS 

When using electrical equipment, basic safety precautions should always 

be followed including the following: 

READ AND FOLLOW ALL SAFETY INSTRUCTIONS 

1. To avoid the possibility of electrical shock, turn off power supply before

installation or servicing. lnstallation and servicing should be performed

by qualified personnel.

2. Product must be installed in accordance with your local electrical code.

lf you are not familiar with these codes and requirements, consult a

qualified electrician.

100-240V/277V AC, 50/60Hz, Suitable for Wet Locations (IP66), Class 1 

*This product must be grounding 

3. Do not change the structure or any commponents of the fixture to

ensure safety.

SAVE THIS INSTRUCTIONS FOR FUTURE REFERENCE 

TO INSTALL: 

Power 

40W /50W 
80W /lOOW 
120W /150W 
160W /200W 

Modules 




Dimension 

231 x316 x120 mm /9.1 x12.4 x4.7" 
304 x316 x120 mm/12.0 xl2.4 x4.7" 
377 x316 x120 mm/14.8 x12.4 x4.7" 
450 x316 x120 mm/17.7 xl2.4 x4.7" 

� >•�"'• �'"� Th,a,= 

1

10- 25 mm /0.4- 1.0 inches 

Weight 

2.4 kg /5.3 Ibs 
3.6 kg /8.0 Ibs 
4.4 kg /9.7 Ibs 
5.4 kg /11.9 Ibs 

Hole Size: 202 x285 mm 

8.0 xll.2 inches 

Hole Size: 275 x28S mm 

10.8 xll.2 inches 

Hole Size: 348 x285 mm 

13. 7 xll.2 inches 

Hole Size: 421 x285 mm 

16.6 xll.2 inches 

Ceiling Panel 

11,_ 

Po

::

r

��::

I

Cord 

�-

-

��----,

Il 

;.b) 

luminaire Main Body 

f.) 

Ceiling Panel 

Remove Ceiling Securing 

Fittings on this side 

3-3

Allen Wrench: 6mm (5/32") 

, ,. - � ... ,  Ceiling Securing Fittings 

: filjJ 

,,'. 

Notice the INSTALLATION DIRECTION 

'., ' 

''

.. 

_  / 

Allen Wrench: 6mm (5/32") 

Ceiling Securing Fittings,,,

,, 

qi'\ 

Notice the INSTALLATION DIRECTION 

\.ltt 

b!),,. 

.. _ ..... 

STANDARD MOUNTING 

STEP 1: 

Open the mounting hole on the Ceiling Panel. 

(See 

Figure 1 

for opening size) 

STEP 2: 

Remove TW0{2) Ceiling Securing Fittings of 

one side, bring the side of Luminaire Frame 

with Ceiling Securing Fittings into Ceiling Panel. 

See 

Figure 3-1. 

Bring entire Luminaire Frame into Ceiling Panel, 

Clamp the Ceiling Panel by Ceiling Securing 

Fittings and tighten by 6mm {5/32") Allen 

Wrench. See 

Figure 3-2. 

Mount the removed Ceiling Securing Fittings 

back to Luminaire Frame, notice that the bath 

sides are opposited. Clamp and tighten by 

6mm {5/32") Allen Wrench. See 

Figure 3-3. 

STEP 3: 

Connect the 

Power Cord 

to the supply wiring 

per 

"Electrical Connections" 

section for 

completing electrical connections . 

Reviews: