Support: 

If a failure or problem is detected please check troubleshooting section in user manual. If problem cannot be solved, please 

contact authorized service center or authorized dealer. 

 

Batteries:

 Rechargeable batteries can be charged and discharged hundreds of times. However, they will eventually wear out. This is not 

a defect or failure so that batteries wear out is not covered by this warranty. 

Battery  lifetime  will  depend  on  operative  conditions  like  working  temperature,  type,  and  frequency  of  discharging  cycles.  Higher  the 

temperature shorter will be the lifetime. Frequent and deep discharging cycles also will short lifetime. For critical applications batteries 

should be revised and replaced periodically. Long storage (longer than 6 months) without required recharging will wear out batteries. 

This situation is not covered by this limited warranty since this is not considered as a defect. Check recharging instructions on user 

manual. 

 

Conditions - Limited Warranty 

1.- Subject to the conditions of this limited warranty, this product is warranted to be free from defects in materials and workmanship at 

the time of XMART supplies the product. 

 

In Europe, warranty time is 2 years on electronic parts and 2 years on internal batteries from XMART invoice date. 

 

In  America,  standard  warranty  times  could  vary  depending  on  country/region  or  can  be  extended  by  purchasing  warranty 

options. Please check warranty plans and extensions with your local distributor.  

2.- If during the warranty period, this product fails to operate under normal use and service, due to defects in materials or workmanship, 

authorized distributor or service center will, at their option, either repair or replace the product in accordance with terms and conditions 

stipulated herein. Transportation expenses are not covered by this limited warranty. 

3.- Warranty is valid only if the original purchasing document, specifying date of purchase, serial  number, and name of the dealer, is 

presented  with  the  product  to  be  revised.  XMART  and  authorized  partners  reserve  the  right  to  refuse  warranty  service  if  any  of  this 

information has been removed, changed, or missing in original invoice document. 

4.- If product is repaired or replaced, repaired, or replaced product will be warranted for the remaining time of the original warranty or for 

90 days on repaired part from date of repair, whichever is longer. 

5.- XMART or their distribution/service partners reserve the right to charge handling fee if returned product is free of failure or it is out of 

warranty because any of the reasons described in this warranty.  

6.- If product is out of warranty a reparation proposal will be sent to the user for his approval. If proposal is not accepted, service center 

will keep product available for the user during 60 continuous days. After this period product would be disposed and user will not be able 

to rise any claim.  

7.- Rechargeable batteries, like included in this product, will definitively wear out even under normal operation. This is not a defect or 

failure, so it is not covered by this warranty.  

8.- This warranty does not cover batteries wear out caused by improper or long storage (over 6 months without required recharging as 

indicated in product manual). Even performing recharging procedure this product cannot be storage longer than 18 months. Problems 

on batteries caused by this kind of long storage are not covered by this warranty. 

9.- This warranty does not cover product failures caused by installations, modifications or repair performed by non-authorized person. If 

product  is  open  by  not  authorized  technician  warranty  will  be  considered  void.  This  warranty  does  not  cover  failure  caused  by 

inadequate installation or maintenance, misuse, accidents, fire, or floods. 

10.- This product can include protection devices like input fuse or input breaker. Activation of this kind of devices is not a failure it is 

caused by an improper product installation. Input fuse or breaker reset, or replacement is not covered by this warranty.  

11.- This warranty does not cover damages produced during transportation from user to technical service caused by improper packing 

of the product by user. 

12.- Warranty terms and conditions cannot be modified or extended by third parties without written approval of XMART. 

 

Limited Warranty 

- XMART does not warrant that the operation of this product will be uninterrupted or error-free during its lifetime. If product fails to work, 

the maximum liability of XMART under this limited warranty is expressly limited to the lesser of the price you have paid for the product or 

the cost of repairing or replacement of any hardware components that malfunction in conditions of normal use. 

- In no event will XMART be liable for any damages caused by the product or the failure of the product to perform, including any lost 

profits or savings or special, incidental, or consequential damages. XMART is not liable for any claim made by a third party to XMART or 

to final user.  

-  XMART  is  not  responsible  for  damage  that  occurs  as  a  result  of  your  failure  to  follow  the  instructions  intended  for  this  hardware 

product. 

 

 

 

 

 

Summary of Contents for Xmart LBU-ONL 1.5K

Page 1: ...n this manual is property of XMART This manual Information cannot be copied or distributed totally or partially without written approval of XMART XMART can introduce modifications in their products or...

Page 2: ...PRODUCT DESCRIPTION 3 SAFETY QUALITY AND PERFORMANCE STANDARDS 4 INSTALLATION 5 OPERATION MODES 6 OPERATION INTERFACE KEYBOARD LCD 7 Inverter CONFIGURATION 8 ERROR ALARMS CODES 9 TROUBLESHOOTING 10 SO...

Page 3: ...ect this Inverter to any of its own power outlets this could damage the unit permanently WARNING Do not connect AC motor based equipment without a careful sizing of the Inverter based on inrush curren...

Page 4: ...14001 2015 TRANSPORTATION IEC EN 60068 2 32 Drop Test IEC EN 60068 2 64 Vibration Test IEC EN 60068 2 27 Shock Test WARNING Modifications made on the product or the use of this product as a part of a...

Page 5: ...to drive maximum rated current For 3KVA Inverter in 120V wires must be minimum 12AWG for lengths shorter than 15m 50 feet Wiring gauge is conditioned to length temperature etc Wiring must be selected...

Page 6: ...ace Inverter module close to original XMART Batteries Array 2 If there are check all Battery DC switches are in OFF position 3 Connect Inverter to first Battery String by using original DC cable 4 In...

Page 7: ...ncludes 2 serial ports USB RS232 Additionally there is also a Smart Port to support different communication cards such as LAN SNMP card Dry Contacts card RS 485 card among others RS232 COMMUNICATION P...

Page 8: ...s mode is adopted in case ON button has not been activated as soon as Inverter detects a valid AC input on its terminals If bypass mode is not enabled Inverter will simply light its LCD Outputs will k...

Page 9: ...r output is generated by inverter BATTERY MODE A Input indicator at bottom left corner A shows Battery voltage since there is no valid AC input detected B Output indicator displays AC output generated...

Page 10: ...ll checking of systems and batteries OFF ENTER Inverter TURN OFF Press for 2 seconds to turn Inverter off ENTER When Inverter is in configuration mode this key operates as ENTER SELECT CHECK VALUES In...

Page 11: ...INFORMATION Displays AC output voltage Output frequency in Hz ALARMS ERRORS This section of the LCD displays active alarms and errors providing codes and descriptive symbols This section also shows r...

Page 12: ...ammable output powered 5 BYAPSS internal static line active 6 ECO mode active 7 Audible alarm beep muted OUTPUT POWER METER This area graphically displays the power supplied by the Inverter with a 4 s...

Page 13: ...ODE ON MUTE Used as key to navigate or changing parameters value OFF ENTER Used as ENTER key to confirm modifications SELECT Used as key to navigate or changing parameters value CONFIGURATION MENU For...

Page 14: ...c Set values with keys 06 BYPASS ENABLE DISABLE Enables or disables BYPASS function when Inverter is off ENA ENABLE DIS DISABLE Factory set DIS 07 BYPASS INPUT VOLTAGE RANGE Valid input VOLTAGE range...

Page 15: ...maximum recharging current in Amps 1 2 4 6 or 8 A Factory set 2 A 14 BOOSTING CHARGING VOLTAGE NO MODIFICATIONS RECOMMENDED ONLY FOR TECHNICIANS Charging voltage can be increased Adjustable Voltage 2...

Page 16: ...DESCRIPTION AO Active Open AC Active Close BAH Battery AH BAT Battery BR Battery Replacement CBV Charger Boost Voltage CFV Charger Float Voltage CF Frequency Converter Function CHA Charger current CH...

Page 17: ...nd codes with intermittent beeps Tipo de ALARMA SIMBOLO INTERMITENTE ALARMA SONORA OVERLOAD Inverter Load exceeds Inverter capacity 1 beep s LOW BATTERY 1 beep 2s BATTERY FAULT 1 beep 2s BATTERY REPLA...

Page 18: ...the Inverter FAILURE CODE ICON BUS START FAIL 01 BUS OVER 02 BUS UNDER 03 Inverter SOFT START FAIL 11 Inverter VOLTAGE HIGH 12 Inverter VOLTAGE LOW 13 Inverter OUTPUT SHORT 14 BATT VOLTAGE TOO HIGH 2...

Page 19: ...n EEPROM Failure Turn off and power off Inverter Restart Inverter If not solved call technical service ERROR CODES PROBABLE CAUSE SOLUCION 01 02 03 Turn off and power off Inverter Disconnect all equip...

Page 20: ...ating Inverter with higher room temperatures will short dramatically battery life IMPORTANT RECHARGING PLAN FOR LONG STORAGE If Inverter and batteries are going to be stored for long time it is mandat...

Page 21: ...charger uses a 3 steps algorithm to care batteries 1 Constant Current During this stage charger injects a constant current meanwhile batteries increase their voltage During this stage batteries recove...

Page 22: ...bution service partners reserve the right to charge handling fee if returned product is free of failure or it is out of warranty because any of the reasons described in this warranty 6 If product is o...

Page 23: ...xmart Inverter com VER 2211 17 One ENG 23 14 REAR PANEL 1 Standard Inverter Outlets 2 Programmable Outlets 3 AC Input 4 Surge Protected RJ45 sockets 5 Emergency Power Off connector 6 USB RS232 7 Smart...

Page 24: ...USER MANUAL LBU ONL 1 5K 2 25K 3K 4 5K www xmart Inverter com VER 2211 17 One ENG 24 15 SPECIFICATIONS 1 2...

Page 25: ...emperatura Almacenaje UPS w o batteries 25 to 55 C UPS with batteries 20 to 50 C CEE Schuko 1 CEE Schuko 2 CEE Schuko 2 L5 30P NEMA5 20P CE IEC EN 62040 1 RoHS ISO9001 ISO14001 IEC EN 61000 2 2 IP21 F...

Page 26: ...n though this inverter can manage battery discharge until 10 5VDC per battery we recommend not using this feature up to the limit but using a higher cut off voltage instead This will give a shorter ba...

Page 27: ...100AH 100AH OF STRINGS 1 2 3 1 2 3 1 2 TOTAL CURRENT 45A 90A 135A 65A 130A 195A 100A 200A 100 550 1180 1768 790 1580 2372 1235 2470 200 225 552 858 374 795 1190 590 1290 300 128 345 575 250 535 825 38...

Page 28: ...2 3 4 1 2 3 1 2 TOTAL CURRENT 45A 90A 135A 180A 65A 130A 195A 100A 200A 150 430 970 1460 1950 655 1306 1960 1020 2040 300 194 490 765 1070 340 720 1075 523 1121 450 120 318 525 740 240 500 770 360 775...

Page 29: ...F STRINGS 1 2 3 1 2 3 1 2 TOTAL CURRENT 45A 90A 135A 65A 130A 195A 100A 200A 200 670 1 340 2 000 655 1 306 1 960 1050 2000 400 345 730 1 090 340 720 1 075 540 1140 600 240 510 760 240 500 770 360 780...

Page 30: ...100AH OF STRINGS 1 2 3 1 2 3 1 2 TOTAL CURRENT 45A 90A 135A 65A 130A 195A 100A 200A 300 450 1025 1500 690 1300 2000 1080 2100 600 200 500 780 350 740 1100 540 1150 900 122 325 540 245 520 800 365 790...

Page 31: ...USA Miami FL 33196 USA sales xmart Inverter com EUROPE Sabadell Barcelona 08202 Spain sales xmart Inverter com LATAM Santiago de Chile Chile sales xmart Inverter com...

Reviews: