RDA-7
20
RDA-7 Primary Connections For Different Voltages
AC Board Jumpers
For voltages in the 100V - 120V range, install the two jumpers marked L
For voltages in the 200V - 240V range install the single jumper marked H
Main Transformer Jumpers
The following connections should be made for different line voltages:
100V:
K1-3 to BL1-4,
P7 to BL1-3
P2 to BL1-2
K2-3 to BL1-12,
P8 to BL1-11
P3 to BL1-10
110V:
K1-3 to BL1-6,
P7 to BL1-5
P2 to BL1-2
K2-3 to BL1-14,
P8 to BL1-13
P3 to BL1-10
120V:
K1-3 to BL1-8,
P7 to BL1-7
P2 to BL1-2
K2-3 to BL1-16,
P8 to BL1-15
P3 to BL1-10
200V:
K1-3 to BL1-4
BL1-2 to BL1-3
K2-3 to BL1-12
BL1-10 to BL1-11
220V:
K1-3 to BL1-6
BL1-2 to BL1-5
K2-3 to BL1-14
BL1-10 to BL1-13
230V:
K1-3 to BL1-6
BL1-2 to BL1-7
K2-3 to BL1-14
BL1-10 to BL1-15
240V:
K1-3 to BL1-8
BL1-2 to BL1-7
K2-3 to BL1-16
BL1-10 to BL1-15
Summary of Contents for RDA-7
Page 7: ...RDA 7 7 CHASSIS EXPLODED VIEW Top Cover Amp Module Front Panel Assembly Chassis...
Page 16: ...RDA 7 16 SCREWS 14 GROU 14 1...
Page 17: ...RDA 7 17 11 11 1 13 13 13 12 13 1 13 4 13 2 13 2 13 2 12 1 13 3 13 3 13 3 6 6 1...
Page 19: ...RDA 7 19 Pcboard Component side view from circuit side Circuit side view from component side...
Page 22: ...RDA 7 22 POWER SUPPLY SCHEMATIC DIAGRAMS...
Page 23: ...RDA 7 23 DRIVER CIRCUIT...
Page 24: ...RDA 7 24 OUTPUT STAGE AND PROTECTION...
Page 25: ...RDA 7 25 PROTECTION...
Page 26: ...RDA 7 26 AC BOARD...
Page 27: ...RDA 7 27 PROTECTION WIRING...
Page 29: ......